0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      X-ray dosimetry in breast cancer screening: 2D and 3D mammography.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          According to the World Health Organization (WHO), at the end of 2020, 7.8 million women alive were diagnosed with breast cancer in the past 5 years, making it the world's most prevalent cancer. It is largely recognized and demonstrated that early detection represents the first strategy to follow in the fight against cancer. The effectiveness of mammography screening for early breast cancer detection has been proven in several surveys and studies over the last three decades. The estimation of the Mean Glandular Dose (MGD) is important to understand the radiation-associated risk from breast x-ray imaging exams. It continues to be the subject of numerous studies and debates, since its accuracy is directly related to risk estimation and for optimizing breast cancer screening programs. This manuscript reviews the main dosimetry formalisms used to estimate the MGD in mammography and to understand the continuing efforts to reduce the absorbed dose over the last forty years. The dosimetry protocols were formulated initially for mammography. Digital breast tomosynthesis (DBT) either in conjunction with synthesized digital mammogram (SDM) or with digital mammography (DM), is routinely used in many breast cancer screening programs and consequently the dosimetry protocols were extended for these techniques.

          Related collections

          Author and article information

          Journal
          Eur J Radiol
          European journal of radiology
          Elsevier BV
          1872-7727
          0720-048X
          Jun 2022
          : 151
          Affiliations
          [1 ] Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10, km 139,7, 2695-066 Bobadela LRS, Portugal. Electronic address: salvatore@ctn.tecnico.ulisboa.pt.
          [2 ] Department of Medical Imaging, The University of Arizona, Tucson, AZ 85724, USA.
          [3 ] Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10, km 139,7, 2695-066 Bobadela LRS, Portugal.
          Article
          S0720-048X(22)00128-0
          10.1016/j.ejrad.2022.110278
          35430441
          1e0c03fc-9eee-42ec-b164-535f6a2bdf19
          History

          Digital Breast Tomosynthesis,Mean glandular dose,Screening mammography,X-ray breast dosimetry

          Comments

          Comment on this article