      Evaluation of resistance against bacterial microleakage of a new conical implant-abutment connection versus conventional connections: an in vitro study.

      Read this article at

      ScienceOpenPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The aim of the present in vitro study was to evaluate bacterial microleakage from inside to outside the implant-abutment assembly in a new design of internal conical connection compared to eight different internal connections. The design of this connection should prevent or limit microbiologic leakage into the surrounding implant tissue, that could contribute to infections without bone loss (mucositis) or with bone loss (peri-implantits). In order to investigate bacterial microleakage, the inner part of each system was inoculated with an Escherichia coli suspension. Eight different groups were considered; each group was composed of 10 dental implants, for a total of 80 implants. Groups 1-7 were considered controls, while group 8 was the test connection (an internal connection characterized by a double taper principle). Results showed that in control implants (Group 1 to 7), little microleakage was observed after the first 6 hours (500 CFU/ μl) and, after 24 hours of incubation, they showed a significant bacterial contamination in all samples (>100.000 CFU/ μl). In group 8 (test connection) no contamination was found in the first 6 hours, with 7 out of 10 implants showing no contamination even after 96 hours. Statistically significant differences were found between Group 8 and the other groups (p<0.05), whereas no significant differences were found among implants of the control groups (from group 1 to 7). Within the limits of the present study, the new connection studied presented significantly less microleakage at 96 h in comparison with the other control internal connections.

          Related collections

          Author and article information

          Journal
          New Microbiol.
          The new microbiologica
          1121-7138
          1121-7138
          Jan 2016
          : 39
          : 1
          Affiliations
          [1 ] Dental School, Vita-Salute University, Milan, Italy and Department of Dentistry, IRCCS San Raffaele Hospital, Milan, Italy.
          [2 ] Laboratory of Microbiology and Virology, Vita-Salute San Raffaele University, Milan, Italy.
          Article
          26922985
          1e8b3b0d-1c13-4259-9e86-ccabbfcdcfc7
          History

          Taper connection,Internal conical,Dental implant,Abutment,Bacterial leakage,Connection

          Comments

          Comment on this article