      Reconstruction of displaced acromio-clavicular joint dislocations using a triple suture-cerclage: description of a safe and efficient surgical technique

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          In this retrospective study we investigated the clinical and radiological outcome after operative treatment of acute Rockwood III-V injuries of the AC-joint using two acromioclavicular (AC) cerclages and one coracoclavicular (CC) cerclage with resorbable sutures.

          Methods

          Between 2007 and 2009 a total of 39 patients fit the inclusion criteria after operative treatment of acute AC joint dislocation. All patients underwent open reduction and anatomic reconstruction of the AC and CC-ligaments using PDS® sutures (Polydioxane, Ethicon, Norderstedt, Germany). Thirty-three patients could be investigated at a mean follow up of 32±9 months (range 24–56 months).

          Results

          The mean Constant score was 94.3±7.1 (range 73–100) with an age and gender correlated score of 104.2%±6.9 (88-123%). The DASH score (mean 3.46±6.6 points), the ASES score (94.6±9.7points) and the Visual Analogue Scale (mean 0.5±0,6) revealed a good to excellent clinical outcome. The difference in the coracoclavicular distance compared to the contralateral side was <5 mm for 28 patients, between 5-10 mm for 4 patients, and more than 10 mm for another patient. In the axial view, the anterior border of the clavicle was within 1 cm (ventral-dorsal direction) of the anterior rim of the acromion in 28 patients (85%). Re-dislocations occured in three patients (9%).

          Conclusion

          Open AC joint reconstruction using AC and CC PDS cerclages provides good to excellent clinical results in the majority of cases. However, radiographically, the CC distance increased significantly at final follow up, but neither the amount of re-dislocation nor calcifications of the CC ligaments or osteoarthritis of the AC joint had significant influence on the outcome.

          Level of evidence

          Case series, Level IV

          Related collections

          Most cited references33

          • Record: found
          • Abstract: found
          • Article: not found

          A clinical method of functional assessment of the shoulder.

          Several methods have been devised to estimate shoulder function, none of which is entirely satisfactory. The method described in this article is applicable irrespective of the details of the diagnostic or radiologic abnormalities caused by disease or injury. The method records individual parameters and provides an overall clinical functional assessment. It is accurately reproducible by different observers and is sufficiently sensitive to reveal even small changes in function. The method is easy to perform and requires a minimal amount of time for evaluation of large population groups.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Treatment of acromioclavicular injuries, especially complete acromioclavicular separation.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The anatomic reconstruction of acromioclavicular joint dislocations using 2 TightRope devices: a biomechanical study.

              For the reconstruction of acromioclavicular (AC) joint separation, several operative procedures have been described; however, the anatomic reconstruction of both coracoclavicular ligaments has rarely been reported. The aim of this biomechanical study is to describe a new procedure for anatomic reconstruction of the AC joint. Controlled laboratory study. Forty fresh-frozen cadaveric shoulders were tested. Cyclic loading and a load-to-failure protocol was performed in vertical (native, n = 10; reconstructed, n = 10) and anterior directions (native, n = 10; reconstructed, n = 10) on 20 AC joints and repeated after anatomic reconstruction. Reconstruction of conoid and trapezoid ligaments was achieved by 2 TightRope devices (Arthrex, Naples, Florida). Dynamic, cyclic, and static loading until failure in vertical (n = 5) and horizontal (n = 5) directions were tested in native as well as reconstructed joints in a standardized setting. The native coracoclavicular ligaments in static load for vertical force measured 598 N (range, 409-687), elongation 10 mm (range, 6-14), and stiffness 99 N/mm (range, 67-130); static load for anterior force was 338 N (range, 186-561), elongation 4 mm (range, 3-7), and stiffness 140 N/mm (range, 70-210). The mean maximum static load until failure in reconstruction for vertical force was 982 N (range, 584-1330) (P =.001), elongation 4 mm (range, 3-6) (P < .001), and stiffness 80 N/mm (range, 66.6-105) (P = .091); and for anterior static force 627 N (range, 364-973) (P < .001), elongation 6.5 mm (range, 4-10) (P = .023), and stiffness 78 N/mm (range, 46-120) (P = .009). During dynamic testing of the native coracoclavicular ligaments, the mean amount of repetitions (100 repetitions per stage, stage 0-100 N, 100-200 N, 200-300 N, etc, and a frequency of 1.5 Hz) in native vertical direction was 593 repetitions (range, 426-683) and an average of 552 N (range, 452-683) load until failure. In vertical reconstructed testing, there were 742 repetitions (range, 488-893) (P = .222) with a load until failure of 768 N (range, 486-900) (P = .095). In the anterior direction load, the native ligament failed after an average of 365 repetitions (range, 330-475) and an average load of 360 N (range, 307-411), while reconstructed joints ended in 549 repetitions (range, 498-566) (P = .008) with a load until failure of 547 N (range, 490-585) (P = .008). In all testing procedures, a preload of 5 N was performed. The anatomic reconstruction of the AC joint using TightRope is a stable and functional anatomic reconstruction procedure. The reconstruction technique led to favorable in vitro results with equal or even higher forces than native ligaments. Through anatomic repair, stable function of the AC joint can be achieved in an anatomic manner.
                Bookmark

                Author and article information

                Journal
                Patient Saf Surg
                Patient Saf Surg
                Patient Safety in Surgery
                BioMed Central
                1754-9493
                2012
                25 October 2012
                : 6
                : 25
                Affiliations
                [1 ]Department of Traumatology, Klinikum rechts der Isar, Technical University Munich, Ismaninger Str. 22, Munich D- 81675, Germany
                [2 ]Berufsgenossenschaftliche Unfallklinik Tuebingen, Schnarrenbergstr. 9, Tuebingen D- 72076, Germany
                Article
                1754-9493-6-25
                10.1186/1754-9493-6-25
                3503776
                23098339
                1f9fa058-b410-4175-8653-826cb5a9c0de
                Copyright ©2012 Sandmann et al.; licensee BioMed Central Ltd.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 2 August 2012
                : 19 October 2012
                Categories
                Research

                Surgery
                acromioclavicular joint,cerclage,rockwood,dislocation
                Surgery
                acromioclavicular joint, cerclage, rockwood, dislocation

                Comments

                Comment on this article