          Abstract

          G nerve agents are colorless, odorless, and lethal chemical warfare agents (CWAs). The threat of CWAs, which cause critical damage to humans, continues to exist, e.g., in warfare or terrorist attacks. Therefore, it is important to be able to detect these agents rapidly and with a high degree of sensitivity. In this study, a surface acoustic wave (SAW) array device with three SAW sensors coated with different sensing materials and one uncoated sensor was tested to determine the most suitable material for the detection of nerve agents and related simulants. The three materials used were polyhedral oligomeric silsesquioxane (POSS), 1-benzyl-3-phenylthiourea (TU-1), and 1-ethyl-3-(4-fluorobenzyl) thiourea (TU-2). The SAW sensor coated with the POSS-based polymer showed the highest sensitivity and the fastest response time at concentrations below the median lethal concentration (LCt 50) for tabun (GA) and sarin (GB). Also, it maintained good performance over the 180 days of exposure tests for dimethyl methylphosphonate (DMMP). A comparison of the sensitivities of analyte vapors also confirmed that the sensitivity for DMMP was similar to that for GB. Considering that DMMP is a simulant which physically and chemically resembles GB, the sensitivity to a real agent of the sensor coated with POSS could be predicted. Therefore, POSS, which has strong hydrogen bond acid properties and which showed similar reaction characteristics between the simulant and the nerve agent, can be considered a suitable material for nerve agent detection.

          Related collections

          Most cited references36

          • Record: found
          • Abstract: not found
          • Article: not found

          Crystallization behavior of poly(ε-caprolactone)/layered double hydroxide nanocomposites

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            POSS related polymer nanocomposites

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Mechanism of operation and design considerations for surface acoustic wave device vapour sensors

                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel)
                sensors
                Sensors (Basel, Switzerland)
                MDPI
                1424-8220
                08 December 2020
                December 2020
                : 20
                : 24
                : 7028
                Affiliations
                [1 ]Laboratory of Intelligent Devices and Thermal Control, Department of Mechanical Engineering, INHA University, inha-ro 100, Incheon 22212, Korea; 22191015@ 123456inha.edu (J.K.); hyewon.park@ 123456inha.edu (H.P.)
                [2 ]Inha Institute of Space Science and Technology (Inha IST), INHA University, inha-ro 100, Incheon 22212, Korea; jihyunn.kim@ 123456inha.ac.kr (J.K.); siry0305@ 123456naver.com (B.-I.S.)
                Author notes
                [* ]Correspondence: joohyung.kim@ 123456inha.ac.kr ; Tel.: +82-032-860-7315
                Article
                sensors-20-07028
                10.3390/s20247028
                7764754
                33302508
                22631493-024c-4e52-a409-c0b7f33fb0e8
                © 2020 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 12 November 2020
                : 01 December 2020
                Categories
                Letter

                Biomedical engineering
                saw array sensor,chemical warfare agent,surface acoustic wave,polyhedral oligomeric silsesquioxane,dimethyl methylphosphonate

                Comments

                Comment on this article