          Respiratory rate (RR) is typically the first vital sign to change when a patient decompensates. Despite this, RR is often monitored infrequently and inaccurately. The Circadia Contactless Breathing Monitor™ (model C100) is a novel device that uses ultra-wideband radar to monitor RR continuously and un-obtrusively. Performance of the Circadia Monitor was assessed by direct comparison to manually scored reference data. Data were collected across a range of clinical and non-clinical settings, considering a broad range of user characteristics and use cases, in a total of 50 subjects. Bland–Altman analysis showed high agreement with the gold standard reference for all study data, and agreement fell within the predefined acceptance criteria of ±5 breaths per minute (BrPM). The 95% limits of agreement were −3.0 to 1.3 BrPM for a nonprobability sample of subjects while awake, −2.3 to 1.7 BrPM for a clinical sample of subjects while asleep, and −1.2 to 0.7 BrPM for a sample of healthy subjects while asleep. Accuracy rate, using an error margin of ±2 BrPM, was found to be 90% or higher. Results demonstrate that the Circadia Monitor can effectively and efficiently be used for accurate spot measurements and continuous bedside monitoring of RR in low acuity settings, such as the nursing home or hospital ward, or for remote patient monitoring.

          Related collections

          Most cited references46

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Wearable Sensors for Remote Health Monitoring

          Life expectancy in most countries has been increasing continually over the several few decades thanks to significant improvements in medicine, public health, as well as personal and environmental hygiene. However, increased life expectancy combined with falling birth rates are expected to engender a large aging demographic in the near future that would impose significant  burdens on the socio-economic structure of these countries. Therefore, it is essential to develop cost-effective, easy-to-use systems for the sake of elderly healthcare and well-being. Remote health monitoring, based on non-invasive and wearable sensors, actuators and modern communication and information technologies offers an efficient and cost-effective solution that allows the elderly to continue to live in their comfortable home environment instead of expensive healthcare facilities. These systems will also allow healthcare personnel to monitor important physiological signs of their patients in real time, assess health conditions and provide feedback from distant facilities. In this paper, we have presented and compared several low-cost and non-invasive health and activity monitoring systems that were reported in recent years. A survey on textile-based sensors that can potentially be used in wearable systems is also presented. Finally, compatibility of several communication technologies as well as future perspectives and research challenges in remote monitoring systems will be discussed.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Range Correlation and<tex>\(I/ Q\)</tex>Performance Benefits in Single-Chip Silicon Doppler Radars for Noncontact Cardiopulmonary Monitoring

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Respiratory rate: the neglected vital sign

                Bookmark

                Author and article information

                Contributors
                Role: Academic Editor
                Journal
                Sensors (Basel)
                Sensors (Basel)
                sensors
                Sensors (Basel, Switzerland)
                MDPI
                1424-8220
                11 June 2021
                June 2021
                : 21
                : 12
                : 4027
                Affiliations
                Circadia Technologies Ltd., 6 Delmey Close, London CR0 5QD, UK; michal@ 123456circadia.health (M.M.); fs@ 123456circadia.health (F.S.); saad.marfani@ 123456gmail.com (S.M.); guy@ 123456circadia.health (G.D.L.); adrian@ 123456circadia.health (A.J.W.)
                Author notes
                [* ]Correspondence: timo@ 123456circadia.health
                [†]

                These authors contributed equally to this work.

                Author information
                https://orcid.org/0000-0002-4518-0063
                https://orcid.org/0000-0002-4074-0287
                Article
                sensors-21-04027
                10.3390/s21124027
                8230718
                34207961
                277b2867-0e51-487d-8a75-9fdb0a97ea25
                © 2021 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( https://creativecommons.org/licenses/by/4.0/).

                History
                : 13 May 2021
                : 08 June 2021
                Categories
                Article

                Biomedical engineering
                respiratory rate monitor,continuous vital sign monitoring,contactless monitor,remote patient monitoring,ultra-wideband radar,performance validation,analysis of agreement

                Comments

                Comment on this article