      Delayed diagnosis of a retained guidewire after bedside femoral venous catheter insertion: A preventable complication

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Central venous catheter (CVC) insertion is a commonly performed procedure that is used for continuous invasive hemodynamic monitoring, fluid resuscitation, drug therapy, and hemodialysis. CVC placement can be associated with serious complications that are mostly preventable. One of these complications is the loss of the guidewire within the intravascular space, which carries a high morbidity and mortality. Here, we describe a 44-year old patient who presented with acute kidney injury and metabolic derangements that necessitated bedside right femoral dialysis catheter to initiate emergent renal replacement therapy. A day after the catheter insertion, the guidewire was noted on a routine chest X-ray extending into the base of the skull. The clinical course was complicated with cerebral infarction. Subsequently, the retained guidewire was removed a few days after the CVC insertion. In summary, the retained guidewire within the circulation is associated with potentially life-threatening and hazardous outcomes. Continuing education, vigilant supervision, and implementing certain protocols are likely to prevent such undesirable events.

          Related collections

          Most cited references11

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Guidewire-Related Complications during Central Venous Catheter Placement: A Case Report and Review of the Literature

          Seldinger's technique is widely used to place central venous and arterial catheters and is generally considered safe. The technique does have multiple potential risks. Guidewire-related complications are rare but potentially serious. We describe a case of a lost guidewire during central venous catheter insertion followed by a review of the literature of this topic. Measures which can be taken to prevent such complications are explained in detail as well as recommended steps to remedy errors should they occur.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Retrieval of intravascular foreign bodies: experience in 32 cases.

            Recent reports suggest that both the nature of intravascular foreign bodies and the tools available to retrieve them have changed substantially in the past decade. We reviewed our recent experience with percutaneous retrieval of intravascular foreign bodies to determine the efficacy and safety of the procedure using currently available devices. Between 1990 and 1994, we attempted retrieval of 35 intravascular foreign bodies in 32 patients. Twelve patients (38%), including all five with intraarterial foreign bodies, were treated for complications of transcatheter interventional procedures that resulted in embolization of seven coils, four intravascular stents, an inferior vena cava filter, and a valvuloplasty balloon fragment. From procedure records, we reviewed the types of retrieval devices and methods used; the medical record was studied to determine the occurrence and treatment of any procedure-related complications. Retrieval was successful in 31 (97%) of 32 patients. All five intraarterial and 29 of 30 IV objects were removed. Nitinol goose-neck snares were used in 28 of 32 cases, but more than one retrieval system was required in eight cases (25%), often using grasping forceps, tip-deflecting wires, or stone baskets to move the foreign body into a more favorable position for snaring. In the single failure, the tip of a largely extravascular catheter fragment lay in a venous valve and could not be snared in a patient who refused surgery. Two of five patients with arterial foreign bodies suffered occlusive arterial spasm, reversible with local administration of nitroglycerine. Two large objects were repositioned to the femoral vein and removed by surgical cutdown. No other procedural complications occurred, and none of the patients required additional compression, transfusion, or surgical intervention. We conclude that use of preformed nitinol goose-neck snares facilitates retrieval of intravascular foreign bodies in most cases, although interventional radiologists must be familiar with a variety of techniques to deal with the expanding spectrum of foreign bodies currently encountered.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Missed Central Venous Guide Wires

              The inadvertent loss of an entire guide wire during central venous catheterization can lead to serious patient harm and require additional investigations as well as retrieval procedures. We aimed to analyze globally published reports of lost wires during central venous catheterization to understand its possible etiology, presentation, treatment, and outcomes with an objective of finding solutions to make the procedure safer.
                Bookmark

                Author and article information

                Contributors
                Journal
                Radiol Case Rep
                Radiol Case Rep
                Radiology Case Reports
                Elsevier
                1930-0433
                22 December 2021
                March 2022
                22 December 2021
                : 17
                : 3
                : 647-649
                Affiliations
                [a ]Biology Department, University of Alabama at Birmingham, Birmingham, AL, USA
                [b ]Biology Department, University of Alaska at Anchorage, Anchorage, AK, USA
                [c ]Department of Radiology and Medicine, University of Alabama at Birmingham, Birmingham, AL, USA
                Author notes
                [* ]Corresponding author. A. Almehmi, 1670 University Blvd, Birmingham, AL 35233 aalmehmi@ 123456uabmc.edu
                Article
                S1930-0433(21)00816-5
                10.1016/j.radcr.2021.11.030
                8715130
                35027989
                2aa0d7c1-87aa-4d7b-8848-42b54cb66ff4
                © 2021 The Authors. Published by Elsevier Inc. on behalf of University of Washington.

                This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

                History
                : 3 November 2021
                : 12 November 2021
                Categories
                Case Report

                central venous catheter,retained guidewire,retrieval

                Comments

                Comment on this article