47
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Synthetic bone graft substitutes.

      Anz Journal of Surgery
      Aluminum Oxide, therapeutic use, Biocompatible Materials, Bone Cements, Bone Regeneration, Bone Substitutes, Bone Transplantation, methods, Calcium Phosphates, Calcium Sulfate, Durapatite, Humans, Hydroxyapatites

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Replacement of extensive local bone loss is a significant clinical challenge. There are a variety of techniques available to the surgeon to manage this problem, each with their own advantages and disadvantages. It is well known that there is morbidity associated with harvesting of autogenous bone graft and limitations in the quantity of bone available. Alternatively allografts have been reported to have a significant incidence of postoperative infection and fracture as well as the potential risk of disease transmission. During the past 30 years a variety of synthetic bone graft substitutes has been developed with the aim to minimize these complications. The benefits of synthetic grafts include availability, sterility and reduced morbidity. The present article examines the relevance of synthetic bone graft substitutes, their mechanical properties and clinical application.

          Related collections

          Most cited references48

          • Record: found
          • Abstract: not found
          • Article: not found

          Potential of ceramic materials as permanently implantable skeletal prostheses.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Surface-active biomaterials.

            Since the discovery in 1969 of a man-made surface-active material that would bond to bone, a range of materials with the same ability has been developed. These include glass, glass-ceramic, and ceramic materials which have a range of reaction rates and from which it should be possible to select a surface-active material for a specific application. The available materials and their similarities, differences, and current clinical applications are reviewed.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties.

              In 1985, the Norwegian Orthopaedic Association decided to establish a national hip register, and the Norwegian Arthroplasty Register was started in 1987. In January 1994, it was extended to include all artificial joints. The main purpose of the register is to detect inferior results of implants as early as possible. All hospitals participate, and the orthopedic surgeons are supposed to report all primary operations and all revisions. Using the patient's unique national social security number, the revision can be linked to the primary operation, and survival analyses of the implants are done. In general, the survival analyses are performed with the Kaplan-Meier method or using Cox multiple regression analysis with adjustment for possible confounding factors such as age, gender, and diagnosis. Survival probabilities can be calculated for each of the prosthetic components. The end-point in the analyses is revision surgery, and we can assess the rate of revision due to specific causes like aseptic loosening, infection, or dislocation. Not only survival, but also pain, function, and satisfaction have been registered for subgroups of patients. We receive reports about more than 95% of the prosthesis operations. The register has detected inferior implants 3 years after their introduction, and several uncemented prostheses were abandoned during the early 1990s due to our documentation of poor performance. Further, our results also contributed to withdrawal of the Boneloc cement. The register has published papers on economy, prophylactic use of antibiotics, patients' satisfaction and function, mortality, and results for different hospital categories. In the analyses presented here, we have compared the results of primary cemented and uncemented hip prostheses in patients less than 60 years of age, with 0-11 years' follow-up. The uncemented circumferentially porous- or hydroxyapatite (HA)-coated femoral stems had better survival rates than the cemented ones. In young patients, we found that cemented cups had better survival than uncemented porous-coated cups, mainly because of higher rates of revision from wear and osteolysis among the latter. The uncemented HA-coated cups with more than 6 years of follow-up had an increased revision rate, compared to cemented cups due to aseptic loosening as well as wear and osteolysis. We now present new findings about the six commonest cemented acetabular and femoral components. Generally, the results were good, with a prosthesis survival of 95% or better at 10 years, and the differences among the prosthesis brands were small. Since the practice of using undocumented implants has not changed, the register will continue to survey these implants. We plan to assess the mid- and long-term results of implants that have so far had good short-term results.
                Bookmark

                Author and article information

                Comments

                Comment on this article