53
views
0
recommends
+1 Recommend
0 collections
    7
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems.

      European Journal of Oral Sciences
      Aluminum Oxide, chemistry, Ceramics, Computer-Aided Design, Dental Abutments, Dental Porcelain, Dental Veneers, Denture Design, methods, Denture, Partial, Fixed, Humans, Metal Ceramic Alloys, Microscopy, Replica Techniques, Surface Properties, Zirconium

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In this study, the hypothesis was tested that the marginal and internal fit of CAD/CAM fabricated all-ceramic three-unit fixed partial dentures (FPDs) can be as good as in metal-ceramic FPDs. Twenty-four all-ceramic FPDs were fabricated and randomly subdivided into three equally sized groups. Eight frameworks were fabricated using the Digident CAD/CAM system (DIGI), another eight frameworks using the Cerec Inlab system (INLA). Vita Inceram Zirkonia blanks were used for both groups. In a third group frameworks were milled from yttrium-stabilized Zirconium blanks using the Lava system (LAVA). All frameworks were layered with ceramic veneering material. In addition, six three-unit metal-ceramic FPDs served as control group. All FPDs were evaluated using a replica technique with a light body silicone stabilized with a heavy body material. The replica samples were examined under microscope. The medians of marginal gaps were 75 microm for DIGI, 65 microm for LAVA and INLA and 54 microm for the conventional FPDs. Only the DIGI data differed significantly from those of the conventional FPDs. Within the limits of this study, the results suggest that the accuracy of CAD/CAM generated three-unit FPDs is satisfactory for clinical use.

          Related collections

          Author and article information

          Comments

          Comment on this article