1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      In situ efficiency of filters in residential central HVAC systems.

      1 , 1 , 2
      Indoor air
      Wiley
      bypass, face velocity, filtration, forced air, particles

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          High-efficiency filtration in residential forced-air heating, ventilation, and air conditioning (HVAC) systems protects equipment and can reduce exposure to particulate matter. Laboratory tests provide a measure of the nominal efficiency, but they may not accurately reflect the in situ efficiency of the filters because of variations in system conditions and changes in filter performance over time. The primary focus of this paper is to evaluate the effective filtration efficiency, which is inclusive of any loading and system impacts, in 21 occupied residential homes through in-duct concentration measurements. We considered the role of filter media by testing both electret and non-electret media, as well as the role of loading by considering new and used filters. The results show that filters with higher nominal efficiency generally had higher effective filtration efficiency in the same home. In terms of performance change, there is no significant difference in efficiency between initial and 3-month non-electret filters, but the efficiency of electret filters generally decreased over time. However, both nominal efficiency and performance change were vastly overshadowed by the wide variety in loading and system conditions across homes, making it hard to predict filter efficiency in a given home without in situ measurements.

          Related collections

          Author and article information

          Journal
          Indoor Air
          Indoor air
          Wiley
          1600-0668
          0905-6947
          March 2020
          : 30
          : 2
          Affiliations
          [1 ] Department of Civil and Mineral Engineering, University of Toronto, Toronto, ON, Canada.
          [2 ] Dalla Lana School of Public Health, University of Toronto, Toronto, ON, Canada.
          Article
          10.1111/ina.12633
          31845406
          4c2149d6-4b26-47d9-b829-d1d9816b5fc0
          © 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
          History

          particles,forced air,filtration,bypass,face velocity
          particles, forced air, filtration, bypass, face velocity

          Comments

          Comment on this article