31
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      The development of the heart and microcirculation: role of shear stress

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction The structural and morphological aspects of heart development have been well-described over the past years. Continuing research is performed on the genetic pathways, transcription factors and growth factors important for determination and specification of the various components and segments of the cardiovascular system during embryogenesis. It is necessary to realize that the intricate expression patterns and cellular and molecular interactions take place in a growing embryo with an increasing oxygen and fuel consumption. This is accompanied by an expanding cardiovascular system that is continuously adapting to the changing needs of the embryo. As the cardiovascular system is the first to function in an embryo we have to incorporate in our scientific thinking the forces generated by the heart with the local effects on the various components and segments as early as the heart is present. The cyclic activity of the heart generates both pressure and flow, both dampened and transmitted by the physico-chemical characteristics of the wall of the system and of the blood, incorporating their changing composition during development. Here, we will concentrate on the influence of the blood flow and the ensuing shear stress [5] in the rapidly changing geometry of the developing cardiovascular system. The forces exerted on the wall will activate intracellular signaling pathways inducing alterations in gene expression patterns that are at the basis of differentiation steps. As a consequence, abnormal flow patterns and the origin of congenital malformations are closely interlinked. The same holds for disease processes such as plaque formation after birth and during aging. Geometrical changes during development At the time of the first contractions, the heart is an almost straight tube with only a light curvature. The blood becomes pumped regularly from the caudally located venous pole towards the cranially located arterial pole. Here, the heart is connected to the aortic sac that divides in a bilateral set of pharyngeal (or branchial) arteries. The latter expands from only one left and right artery towards as many as five sets in a tightly controlled pattern of, e.g., adding the fourth set, whereas the first set disappears. The pharyngeal arch arterial system in whatever constellation in an early embryo, will aggregate towards the partly bilateral dorsal aorta (Fig. 1). Finally, the pharyngeal arterial system and dorsal aorta will become asymmetric because several segments disappear on one side, but persist on the contralateral side. Remnants of the disappearing vessels, however, can still be found as they remain connected to microcirculatory networks in, e.g., the craniofacial region. Flow dividers and complex 3D curves are inherent to the changing geometry of the arterial system and are, therefore, players in the shear stress theatre. Fig. 1 Computerized reconstructions after serial histological sections of embryos represent three subsequent stages of the developing chick heart. First row (a–d), left lateral view of Hamburger Hamilton (HH) stage18. Second row (e–h), left ventrolateral view HH24. Third row (i–l), ventral view HH27. The cardiac and vascular compartments are annotated in d, h and l, respectively. Note the disappearance of the second pharyngeal arch artery PAA (compare d, h) and the emergence of the sixth one in h. The asterisk denotes the inner curvature of the looping heart that becomes tighter during development. The outflow tract (OFT) is connected to the pharyngeal arch arteries (PAA). The OFT is located right sided in HH18, subsequently it becomes wedged between both atria and centrally localized in the cardiac contour in HH27. The stained parts in the columns represent the expression of the respective shear stress-induced genes, KLF2 (blue), ET1 (yellow) and NOS3 (green). Note that KLF2 is restricted to the narrow zones (AVC, OFT, PAA 2, 3, 4), whereas ET1 is preferentially localized in the wider segments. NOS3 is mainly absent from the wider atrial segments. Abbreviations: 2/3/4/6th 2nd, 3rd, 4th and 6th pharyngeal arch arteries, * inner curvature of the heart, A primitive Atrium, AVC Atrioventricular canal, DAo Dorsal aorta, LA left atrium, LV left ventricle, OFT Outflow tract, RA right atrium, RV right ventricle, SV sinus venosus, V primitive ventricle. Figure modified after [12 ] Meanwhile, the heart tube is looping three-dimensionally, while keeping the arterial and venous poles close together. The complex loop results in a tight inner curve and a wider outer curve (Fig. 1) with foreseeable differences in flow and shear profiles. The next step will be local expansion of the outer curve resulting in chamber formation, including atrium and ventricles. Separation of these chambers by septation and valve formation is very complex and beyond the scope of this paper. Nevertheless, this is important to understand the changes in flow in relatively late phases of cardiac development. The rendering of correct and accurate 3D images of the growing and remodeling cardio-vascular system is far from trivial. Several approaches have been used to ascertain lumen boundaries and wall dimensions including optical [24, 54], echo-Doppler ultrasound [6, 24, 35] and even micro-MRI [21, 22, 42]. Casting techniques have provided solid lumen models of specific stages of development [39] that have been confirmed by computational fluid dynamics [7]. The combination of these approaches is needed to assess the reciprocal effects of wall movement by contraction and of fluid flow to generate frictional forces. The ensuing shear stress on the endothelial and endocardial inner lining of the vascular system will be transmitted either intracellularly to result in gene expression changes, e.g., Krüppel-like factor-2 [8], intra-epithelially as, e.g., calcium fluxes [36], or even trans-epithelially as signals towards underlying mesenchyme or myocardium [14]. The venous system connects to the sinus venosus and drains the various parts of the embryo and the extra-embryonic membranes, including the yolk sac and in mammals also the placenta. Although most of the blood is stored in the extra-embryonic membranes, forces are generally low here, and this part of the circulation is mostly ignored. Experimentally, however, it is used as an easily accessible gateway to change the inflow of the blood by, e.g., ligating yolk sac vessels in chicken embryos [13, 20]. Flow patterns in the embryo It is evident that flow patterns and wall geometry are intricately linked. A linear heart tube with sequential chambers as in fish [24, 31] will show similar patterns as the embryonic heart tube in mammals and birds [12, 40]. It is challenging to model and quantify 3D changes during further development of cardiac looping. This step is essential to combine computational fluid dynamics [7, 24] and (micro-) particle velocimetry [23, 26, 54] with vascular wall characteristics, even serving the construction of artificial valves [48] in adult life. Not only flow patterns are important but also the type of flow, being laminar, oscillatory or pulsatile. Furthermore, in vitro experiments demonstrate that KLF2 expression is time dependent [55]. In a continuously growing and remodeling embryonic vascular bed we have to realize that these aspects lead to temporal profiles of changes in shear and concurrent cellular reactions. For this reason reactions evoked under steady flow conditions in vitro are not easily transferable to in embryo situations. Shear stress and gene expression As blood flow is an aspect of the vascular system, which is lined with endothelium and endocardium, these cells are mostly influenced by shear stress. In isolated HUVEC an estimated 3% of the investigated genes are up- or down regulated by laminar shear stress [37] whereas in intact umbilical vein segments even 17% of the genes is affected by mechanical forces, nearly half of these being shear-related [1]. Most of the shear related genes, approximately 900 [1], are not changed by stretch from which it is concluded that endothelial cells are able to discriminate between shear and stretch forces. Laminar shear stress activates integrins and thereby induces changes in gene expression such as MMP9, includes metabolic steps, such as MAPK phosphorylation and results in increased NFκB DNA binding [47]. NFκB is indeed an important intermediary between shear stress and changes in cellular function [16, 38], although the pathways may start differently, e.g., by activating integrins [47], TNFα [38], KLF2 [10, 29], TGFβ-SMAD2 [11], E-selectin [9] and many others. Many of these studies have been performed in vitro and in adult atherosclerosis settings [41]. Vascular remodeling has been linked to hemodynamic forces as well [32, 33], whereas the control of arterial branching has been ascribed to flow-driven regulation of genes such as VEGF and ephrin-B2 [28], The differentiation of the early vascular bed into arterial and venous conduits is likewise flow dependent. Shear stress in the embryo In embryonic stages few reports have demonstrated the involvement of laminar flow on changing gene expression patterns [12, 13, 29]. It is becoming increasingly important to discriminate between various types of flow as it has been demonstrated in adult vessels that laminar, oscillatory and pulsatile flow patterns exert different reactions with respect to the emergence of atherosclerotic events [4, 8, 52, 53]. Patterns of flow responsive genes such as ET1, KLF2 and NOS3 have been analyzed [12] in the early chicken embryo during looping of the cardiac tube (Fig. 1). These genes are differentially expressed in the endocardium and confine to areas with low (ET1) and high shear (KLF2 and NOS3). Low shear areas are found in the wide parts of the heart, whereas high shear is found in the narrow parts, i.e. the atrioventricular canal and the outflow tract. This is nicely illustrated when a computational fluid dynamical model [54] is superimposed on the geometry of the looping heart tube [13, 17] demonstrating low shear in the inner curve and high shear in the outer curve [18], co-localizing with the mentioned gene products. Shear stress sensing Endothelial cells are able to discriminate between cyclic stretch and shear stress [1]. The sensing mechanisms involves, e.g., integrins and caveolae, but also cell junctions and adhesion molecules [30, 49, 56]. The primary cilium also referred to as the cell’s antenna [34, 43] can be added as they are also present on endothelial and endocardial cells [25, 36, 53], even during embryonic development [52]. These cilia dissociate under high and under laminar flow showing their sensitivity to changing flow conditions. Central to these diverse “receptors” is the cytoskeleton, integrating both the microtubular and microfilamentous elements with the primary cilium (unpublished). Cytoskeletal deformation by blood flow, amplified by the primary cilium, activates the membrane linked effector molecules, which then signal to the nucleus to activate gene expression. After induced breakdown of the microtubules or the microfilaments in cells under various flow conditions, the expression of shear dependent genes changes, demonstrating the direct link between flow changes, cytoskeleton and differentiation. Essential in immediate primary cilium-mediated response appears to be a calcium signal as demonstrated in polaris-deficient mice [3] and in polycystic kidney disease, a mutant lacking cilia [36]. Changing hemodynamics results in cardiovascular malformations About a decade ago, the venous clip model was introduced to analyze the effects of venous return to the heart [19, 20] by temporal or permanent ligation of a yolk sac vein, forcing the blood to make a deviation and return to the sinus venosus via a different route. Marking with minute amounts of dyes the return paths (or streamlines) from various veins, they showed that the complete venous flow pattern through the heart was changed. This situation was maintained over prolonged time. It was also evident that the various streamlines hardly mixed, even so in the contracting heart, and remained separate from each other after fusion of small veins into larger collecting vessels. After survival many of these embryos presented with major cardiovascular defects, including ventricular septal defects and outflow tract anomalies [2, 20]. From these results the conclusion seemed warranted that hemodynamic alterations are at the base of congenital cardiovascular defects [18]. The next step was to investigate gene expression patterns in the venous clipped embryos and they changed accordingly [13] providing a direct link between altered hemodynamics, changed gene expression patterns and congenital malformations. Cardiac function has been assayed in these embryos [51] using Doppler-frequency detection methods. Combined with the heart rate, various parameters could be calculated including peak systolic, time averaged, and end diastolic velocities, mean blood flow and stroke volume. The increase of these parameters during normal development is used as golden standard for the interpretation of results after clipping [45, 50]. A combination with pressure-volume loop assessment [44] confirmed an increase in stiffness of the cardiac tube and reduced contractility by the changed mechanical load [46]. The pathways involved are also under investigation with pharmacological approaches using, e.g., epinephrin [27]. This causes a significant increase in heart rate, peak and mean velocities, peak and mean blood flows, stroke volume and aortic diameter. Endothelin receptor blockade resulted in diminished endothelin signaling that is different for the embryonic and the extra-embryonic part of the circulation. This is mainly due to the absence of the ETA receptor in the vitelline vascular system, while both the ETA and ETB receptors are present and apparently functioning in the embryo proper [15]. Summary It is evident that hemodynamic factors have a dominant function already during early cardiogenesis. Flow and ensuing shear stress are sensed by endothelial cells by, ciliary modified, cytoskeletal deformation which then activates a number of subcellular structures and molecules. Shear stress dependent changes mostly converge towards NFκB signaling and DNA binding, thereby altering metabolic paths and influencing differentiation of the cells. Geometry of the vascular system heavily affects the flow and shear patterns, as is the case in the adult vasculature where atheroprone areas nicely coincide with the frequency of the primary cilium as shear stress sensor.

          Related collections

          Most cited references49

          • Record: found
          • Abstract: found
          • Article: not found

          Vascular remodeling of the mouse yolk sac requires hemodynamic force.

          The embryonic heart and vessels are dynamic and form and remodel while functional. Much has been learned about the genetic mechanisms underlying the development of the cardiovascular system, but we are just beginning to understand how changes in heart and vessel structure are influenced by hemodynamic forces such as shear stress. Recent work has shown that vessel remodeling in the mouse yolk sac is secondarily effected when cardiac function is reduced or absent. These findings indicate that proper circulation is required for vessel remodeling, but have not defined whether the role of circulation is to provide mechanical cues, to deliver oxygen or to circulate signaling molecules. Here, we used time-lapse confocal microscopy to determine the role of fluid-derived forces in vessel remodeling in the developing murine yolk sac. Novel methods were used to characterize flows in normal embryos and in embryos with impaired contractility (Mlc2a(-/-)). We found abnormal plasma and erythroblast circulation in these embryos, which led us to hypothesize that the entry of erythroblasts into circulation is a key event in triggering vessel remodeling. We tested this by sequestering erythroblasts in the blood islands, thereby lowering the hematocrit and reducing shear stress, and found that vessel remodeling and the expression of eNOS (Nos3) depends on erythroblast flow. Further, we rescued remodeling defects and eNOS expression in low-hematocrit embryos by restoring the viscosity of the blood. These data show that hemodynamic force is necessary and sufficient to induce vessel remodeling in the mammalian yolk sac.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Mechanotransduction and flow across the endothelial glycocalyx.

            In this inaugural paper, we shall provide an overview of the endothelial surface layer or glycocalyx in several roles: as a transport barrier, as a porous hydrodynamic interface in the motion of red and white cells in microvessels, and as a mechanotransducer of fluid shearing stresses to the actin cortical cytoskeleton of the endothelial cell. These functions will be examined from a new perspective, the quasiperiodic ultrastructural model proposed in Squire et al. [Squire, J. M., Chew, M., Nneji, G., Neal, C., Barry, J. & Michel, C. (2001) J. Struct. Biol. 136, 239-255] for the 3D organization of the endothelial surface layer and its linkage to the submembranous scaffold. We shall show that the core proteins in the bush-like structures comprising the matrix have a flexural rigidity, EI, that is sufficiently stiff to serve as a molecular filter for plasma proteins and as an exquisitely designed transducer of fluid shearing stresses. However, EI is inadequate to prevent the buckling of these protein structures during the intermittent motion of red cells or the penetration of white cell microvilli. In these cellular interactions, the viscous draining resistance of the matrix is essential for preventing adhesive molecular interactions between proteins in the endothelial membrane and circulating cellular components.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Fluid shear stress and the vascular endothelium: for better and for worse.

              As blood flows, the vascular wall is constantly subjected to physical forces, which regulate important physiological blood vessel responses, as well as being implicated in the development of arterial wall pathologies. Changes in blood flow, thus generating altered hemodynamic forces are responsible for acute vessel tone regulation, the development of blood vessel structure during embryogenesis and early growth, as well as chronic remodeling and generation of adult blood vessels. The complex interaction of biomechanical forces, and more specifically shear stress, derived by the flow of blood and the vascular endothelium raise many yet to be answered questions:How are mechanical forces transduced by endothelial cells into a biological response, and is there a "shear stress receptor"?Are "mechanical receptors" and the final signaling pathways they evoke similar to other stimulus-response transduction systems?How do vascular endothelial cells differ in their response to physiological or pathological shear stresses?Can shear stress receptors or shear stress responsive genes serve as novel targets for the design of diagnostic and therapeutic modalities for cardiovascular pathologies?The current review attempts to bring together recent findings on the in vivo and in vitro responses of the vascular endothelium to shear stress and to address some of the questions raised above.
                Bookmark

                Author and article information

                Contributors
                r.e.poelmann@lumc.nl
                Journal
                Med Biol Eng Comput
                Medical & Biological Engineering & Computing
                Springer-Verlag (Berlin/Heidelberg )
                0140-0118
                1741-0444
                29 January 2008
                May 2008
                : 46
                : 5
                : 479-484
                Affiliations
                Department of Anatomy and Embryology, LUMC, Leiden, The Netherlands
                Article
                304
                10.1007/s11517-008-0304-4
                2329736
                18228072
                4daec6e0-34c0-4e9b-9224-eb8981238dd7
                © The Author(s) 2008
                History
                : 25 September 2007
                : 10 January 2008
                Categories
                Special Issue
                Custom metadata
                © International Federation for Medical and Biological Engineering 2008