      Índices de chuva dirigida direcional e análise do nível de umedecimento em fachadas de edifício multipavimentos em Goiânia, GO Translated title: Directional driving rain index and analisys of the moisture level on facades of a multi - storey building in Goiânia, GO

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          As fachadas dos edifícios estão sujeitas a condições de exposição que variam de acordo com as características climatológicas da região onde estão localizadas. A chuva dirigida, associação do vento à chuva, é uma das principais fontes externas de umidade e contribui com o processo de degradação dessas fachadas. O fenômeno é estudado em vários países e, devido à preocupação com seus efeitos, métodos vêm sendo desenvolvidos como forma de mensuração. Neste sentido, o presente trabalho visa obter os primeiros índices de chuva dirigida direcionais para a cidade de Goiânia-GO, bem como verificar a existência de relação desse índice com a umidade medida na superfície das fachadas de um edifício multipavimentos. Para tanto, os índices de chuva dirigida direcionais (ICDd) da média mensal e de janeiro foram calculados aplicando o método semi-empírico, considerando dados meteorológicos do período de 2002 a 2008. Posteriormente, foi realizada a medição experimental de umidade na superfície do revestimento das fachadas de um edifício com 17 pavimentos tipo. As medições foram realizadas sobre as fachadas revestidas com argamassa, no mês de janeiro, após um evento de precipitação pluviométrica. Como resultado, obteve-se que o ICDd da média de todos os meses dos anos analisados e o ICDd de janeiro indicam um comportamento diferenciado de chuva dirigida para cada orientação. As medições de umidade superficial nas fachadas do edifício apontaram a ocorrência de maior umedecimento para as fachadas voltadas à orientação N, bem como no pavimento mais alto (17º) e nas regiões abaixo das janelas.

          Translated abstract

          Building facades are subject to exposure conditions that vary according to the climate characteristics of the region where they are located. Driving rain, wind associated with rain, is a major source of moisture and contributes with the degradation process of those facades. The phenomenon is being studied in several countries and, due to concerns about its effects, different methods for measuring it have been devised. This study aims to obtain a directional driving rain index of the city of Goiania, as well as check whether these indices bear a relationship with the moisture measured on the façade surfaces of a multi-storey building. In order to do that, the directional driving rain index of the monthly average and that of January were calculated applying the semi-empirical method, considering meteorological data of the period 2002 to 2008. Subsequently, experimental measurements of moisture on the surface of the facade rendering of a 17-storey building were carried out. The measurements were made on the facades rendered with mortar, after a rainfall in the month of January. The directional driving rain index of the monthly average of the years analyzed and of January indicated a differential behaviour of driving rain for each direction. The superficial moisture measurements of the building facades indicated the occurrence of higher moisture on north-facing facades, as well as on the higher floor (17th) and in the areas below windows.

          Related collections

          Most cited references9

          • Record: found
          • Abstract: not found
          • Article: not found

          A review of wind-driven rain research in building science

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Mapping defect sensitivity in external mortar renders

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Wind-driven rain on building faces and the driving-rain index

                Bookmark

                Author and article information

                Journal
                ac
                Ambiente Construído
                Ambient. constr.
                Associação Nacional de Tecnologia do Ambiente Construído - ANTAC (Porto Alegre, RS, Brazil )
                1415-8876
                1678-8621
                September 2011
                : 11
                : 3
                : 23-37
                Affiliations
                [01] Goiânia GO orgnameUniversidade Federal de Goiás orgdiv1Escola de Engenharia orgdiv2Programa de Pós-Graduação em Geotecnia, Estruturas e Construção Civil Brasil
                Article
                S1678-86212011000300003 S1678-8621(11)01100303
                54d1aa9b-229e-4c7a-8b11-ce8f580d43aa

                This work is licensed under a Creative Commons Attribution 4.0 International License.

                History
                : 15 April 2011
                : 18 August 2011
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 14, Pages: 15
                Product

                SciELO Brazil

                Categories
                Artigos

                Durabilidade,Facades,Moisture,Driving rain,Durability,Fachada,Umidade,Chuva dirigida

                Comments

                Comment on this article