      Sinus pause during nerve integrity monitoring tube insertion following anesthetic induction with a low-dose neuromuscular blocking agent : A CARE-compliant case report

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Rationale:

          Nerve integrity monitoring (NIM) tubes are commonly used in thyroid surgery to prevent recurrent laryngeal nerve injury. To achieve the optimal electromyographic signal for NIM as intraoperative neural monitoring (IONM), the neuromuscular blocking agent (NMBA) dose should be low. The use of a low-dose NMBA increases the anesthetic and analgesic agent dose required to attenuate the laryngeal reflex during intubation. In addition, since the NMBA onset time is delayed, depending on the situation, anesthesia may become excessively deep or shallow before intubation.

          Patient's concern:

          A 51-year-old woman scheduled for thyroid lobectomy received 0.3 mg/kg of rocuronium. Three minutes later, when the NIM tube was inserted through the vocal cord, the patient's heart rate (HR) was undetectable for 2 seconds.

          Diagnosis:

          We suspected that the use of a high-dose anesthetic agent and remifentanil or the laryngocardiac reflex induced the sinus pause.

          Interventions:

          To maintain the anesthetic depth, we administered 6 vol% of desflurane. Because the patient's systolic blood pressure was 70 mmHg and HR was 30 beats/min, we discontinued the remifentanil infusion and administered 8 mg of ephedrine.

          Outcomes:

          The patient's vital signs recovered to normal levels. Subsequently, there were no episodes of bradycardia or arrhythmia.

          Conclusion:

          Sinus pause or severe bradycardia may occur due to the laryngocardiac reflex or the administration of a high-dose anesthetic and analgesic agent during tracheal intubation in patients who received a low-dose NMBA for IONM induction using an NIM tube. Anesthesiologists should be aware of these risks and take precautions to maintain adequate anesthesia, be prepared to administer vasoactive drugs to increase the blood pressure and HR if needed, and, if possible, intravenously administer lidocaine to attenuate the laryngeal reflex during intubation.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement.

          Intraoperative neural monitoring (IONM) during thyroid and parathyroid surgery has gained widespread acceptance as an adjunct to the gold standard of visual nerve identification. Despite the increasing use of IONM, review of the literature and clinical experience confirms there is little uniformity in application of and results from nerve monitoring across different centers. We provide a review of the literature and cumulative experience of the multidisciplinary International Neural Monitoring Study Group with IONM spanning nearly 15 years. The study group focused its initial work on formulation of standards in IONM as it relates to important areas: 1) standards of equipment setup/endotracheal tube placement and 2) standards of loss of signal evaluation/intraoperative problem-solving algorithm. The use of standardized methods and reporting will provide greater uniformity in application of IONM. In addition, this report clarifies the limitations of IONM and helps identify areas where additional research is necessary. This guideline is, at its forefront, quality driven; it is intended to improve the quality of neural monitoring, to translate the best available evidence into clinical practice to promote best practices. We hope this work will minimize inappropriate variations in monitoring rather than to dictate practice options.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Comparison of two induction regimens using or not using muscle relaxant: impact on postoperative upper airway discomfort.

            Muscle relaxants facilitate tracheal intubation, but they are often not used for short peripheral surgical procedures. The consequences of this practice on the upper airway are still a matter of controversy. We therefore compared the incidence of post-intubation symptoms in a randomized study comparing patients intubated with or without the use of a muscle relaxant. A total of 300 adult patients requiring tracheal intubation for scheduled peripheral surgery were randomly assigned in a double-blind study to an anaesthetic protocol that either included or did not include a muscle relaxant (rocuronium). The primary end-point was the rate of post-intubation symptoms 2 and 24 h after extubation. The secondary end-points were the intubation conditions score (Copenhagen Consensus Conference), the rate of difficult intubations (Intubation Difficulty Scale), and the incidence of adverse haemodynamic events. Post-intubation symptoms were more frequent in patients intubated without the use of a muscle relaxant, whether 2 h (57% vs 43% of patients; P < 0.05) or 24 h (38% vs 26% of patients; P < 0.05) after extubation. Intubation conditions were better when the muscle relaxant was used. In patients intubated without a muscle relaxant, difficult intubation was more common (12% vs 1%; P < 0.05), as were arterial hypotension or bradycardia requiring treatment (12% vs 3% of patients; P < 0.05). The use of a muscle relaxant for tracheal intubation diminishes the incidence of adverse postoperative upper airway symptoms, results in better tracheal intubation conditions, and reduces the rate of adverse haemodynamic events.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Systematic review with meta-analysis of intraoperative neuromonitoring during thyroidectomy.

              Intraoperative neuromonitoring (IONM) has been a commonly used technology during thyroid surgery aimed at reducing the incidence of recurrent laryngeal nerve palsy (RLNP), which is a severe complication and leads to significant impacts on a patient's life. In order to give a comprehensive assessment for potential benefits and disadvantage of IONM, this meta-analysis and systematic review discusses RLNP rate, predictive power, continuous intraoperative neuromonitoring (CIONM), and emphasises application during thyroid cancer surgeries.
                Bookmark

                Author and article information

                Journal
                Medicine (Baltimore)
                Medicine (Baltimore)
                MEDI
                Medicine
                Lippincott Williams & Wilkins (Hagerstown, MD )
                0025-7974
                1536-5964
                23 July 2021
                23 July 2021
                : 100
                : 29
                : e26683
                Affiliations
                Department of Anesthesiology and Pain Medicine, School of Medicine, Kyungpook National University, Daegu, Republic of Korea.
                Author notes
                []Correspondence: Sung-Hye Byun, Department of Anesthesiology and Pain Medicine, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, 807, Hoguk-ro, Buk-gu, Daegu 41404, Republic of Korea (e-mail: stone0311@ 123456naver.com ).
                Author information
                http://orcid.org/0000-0002-9287-5087
                Article
                MD-D-21-03108 26683
                10.1097/MD.0000000000026683
                8294922
                5cdbf538-c67f-43f5-ac9d-4f1fdadd0bc4
                Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc.

                This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0

                History
                : 27 April 2021
                : 9 June 2021
                : 7 July 2021
                Categories
                3300
                Research Article
                Clinical Case Report
                Custom metadata
                TRUE

                intraoperative nerve monitoring,intubation,neuromuscular blocking agents,onset time,sinus pause

                Comments