      Analysis of flow changes in side branches jailed by flow diverters in rabbit models.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Understanding the flow alteration in side branches during flow diversion treatment of cerebral aneurysms is important to prevent ischemic complications and improve device designs. Flow diverters were placed in the aorta of four rabbits crossing the origin of side arteries. Subject-specific computational models were constructed from 3D angiographies and Doppler ultrasounds (DUSs). Flow simulations were run before and after virtually deploying the flow diverters, assuming distal resistances remained unchanged after treatment. All jailed arteries remained patent angiographically 8 weeks after treatment. The computational models estimated decreases compared to pretreatment in the mean flow rates between 2% and 20% and in peak flow rates between 5% and 36%. The major changes were observed during systole. Flow patterns did not exhibit recirculation zones before treatment. Implantation of the flow diverters altered the flow structure only locally near the device wires. No major recirculation regions were created or destroyed. Flow diverters seem safe with respect to perforator or side branch occlusion. Relatively small changes in flow rates through jailed arteries are expected, even for moderate to large degrees of coverage of their origins. These results seem consistent with previous clinical experiences where no or very few complications related to perforator occlusion have been reported.

          Related collections

          Author and article information

          Journal
          Int J Numer Method Biomed Eng
          International journal for numerical methods in biomedical engineering
          Wiley
          2040-7947
          2040-7939
          Oct 2014
          : 30
          : 10
          Affiliations
          [1 ] Center for Computational Fluid Dynamics, College of Sciences, George Mason University, 4400 University Drive, MSN 6A2, Fairfax, VA, 22030, U.S.A.
          Article
          NIHMS598281
          10.1002/cnm.2640
          4466553
          24729467
          6d6015d2-3aa0-491a-a515-afd4afc068f9
          Copyright © 2014 John Wiley & Sons, Ltd.
          History

          cerebral aneurysms,computational fluid dynamics,flow diverters,perforators,rabbit models

          Comments

          Comment on this article