      In vivo photoacoustics and high frequency ultrasound imaging of mechanical high intensity focused ultrasound (HIFU) ablation

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The thermal effect of high intensity focused ultrasound (HIFU) has been clinically exploited over a decade, while the mechanical HIFU is still largely confined to laboratory investigations. This is in part due to the lack of adequate imaging techniques to better understand the in-vivo pathological and immunological effects caused by the mechanical treatment. In this work, we explore the use of high frequency ultrasound (US) and photoacoustics (PA) as a potential tool to evaluate the effect of mechanical ablation in-vivo, e.g. boiling histotripsy. Two mice bearing a neuroblastoma tumor in the right leg were ablated using an MRI-HIFU system conceived for small animals and monitored using MRI thermometry. High frequency US and PA imaging were performed before and after the HIFU treatment. Afterwards, the tumor was resected for further assessment and evaluation of the ablated region using histopathology. High frequency US imaging revealed the presence of liquefied regions in the treated area together with fragmentized tissue which appeared with different reflecting proprieties compared to the surrounding tissue. Photoacoustic imaging on the other hand revealed the presence of deoxygenated blood within the tumor after the ablation due to the destruction of blood vessel network while color Doppler imaging confirmed the blood vessel network destruction within the tumor. The treated area and the presence of red blood cells detected by photoacoustics were further confirmed by the histopathology. This feasibility study demonstrates the potential of high frequency US and PA approach for assessing in-vivo the effect of mechanical HIFU tumor ablation.

          Related collections

          Author and article information

          Journal
          Biomed Opt Express
          Biomed Opt Express
          BOE
          Biomedical Optics Express
          Optical Society of America
          2156-7085
          20 March 2017
          01 April 2017
          20 March 2017
          : 8
          : 4
          : 2235-2244
          Affiliations
          [1 ]Department of Radiology and Nuclear Medicine, Medical UltraSound Imaging Centre, Radboud University Nijmegen Medical Centre, Netherlands
          [2 ]Department of Radiology and Nuclear Medicine, Radboud University Nijmegen Medical Centre, Netherlands
          [3 ]Department of Tumor Immunology, Radboud University Nijmegen Medical Centre, Netherlands
          Author notes
          Article
          PMC5516825 PMC5516825 5516825 283510
          10.1364/BOE.8.002235
          5516825
          28736668
          73c7d736-6198-4a36-ad9b-bff410c043f9
          © 2017 Optical Society of America
          History
          : 26 December 2016
          : 08 March 2017
          : 13 March 2017
          Funding
          Funded by: RadboudUMC PhD grant
          Categories
          Article

          (170.1020) Ablation of tissue,(170.0110) Imaging systems,(110.5120) Photoacoustic imaging,(170.7170) Ultrasound

          Comments

          Comment on this article