0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Contribution of inadequate compensatory enlargement to development of human coronary artery stenosis: An in vivo intravascular ultrasound study

      , , , , ,
      Journal of the American College of Cardiology
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This intravascular ultrasound study sought to examine to what extent native coronary artery stenosis is accompanied by vessel wall thickening or inadequate compensatory enlargement (relative vessel constriction), or both. In human femoral arteries, inadequate compensatory enlargement is reported to be a paradoxic mechanism for the development of severe arterial lumen narrowing. However, it is unclear in human coronary arteries whether inadequate compensatory enlargement contributes to the development of critical arterial stenosis. Thirty-five primary coronary artery lesions from 30 patients (19 men, 11 women; mean [+/- SD] age 65 +/- 13 years) were imaged by intravascular ultrasound. The vessel cross-sectional area and lumen area were measured, and the wall area (vessel cross-sectional area minus lumen area) was calculated at the lesion site and at the proximal and distal reference sites. We defined compensatory enlargement to be present when the vessel cross-sectional area at the lesion site was larger than that at the proximal reference site, inadequate compensatory enlargement when the vessel cross-sectional area at the lesion site was smaller than that at the distal reference site and intermediate remodeling when the vessel cross-sectional area at the lesion site was intermediate between the two reference sites. Compensatory enlargement was observed in 19 (54%) of 35 lesions, inadequate compensatory enlargement in 9 (26%) of 35 and intermediate remodeling in 7 (20%) of 35. In the inadequate compensatory enlargement group, reduction of the vessel cross-sectional area contributed to 39% of lumen reduction. Compensatory enlargement commonly (54%) occurs at stenotic coronary lesions. However inadequate compensatory enlargement results in a substantial amount (39%) of the lumen area reduction in 26% of primary coronary artery lesions.

          Related collections

          Author and article information

          Journal
          Journal of the American College of Cardiology
          Journal of the American College of Cardiology
          Elsevier BV
          07351097
          June 1996
          June 1996
          : 27
          : 7
          : 1571-1576
          Article
          10.1016/0735-1097(96)00071-X
          8636538
          7746af85-0bae-494e-960b-8bb534c99259
          © 1996

          https://www.elsevier.com/tdm/userlicense/1.0/

          https://www.elsevier.com/open-access/userlicense/1.0/

          History

          Comments

          Comment on this article