      Multivariate Thermo-Hygrometric Characterisation of the Archaeological Site of Plaza de l’Almoina (Valencia, Spain) for Preventive Conservation

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Preventive conservation requires monitoring and control of the parameters involved in the deterioration process, mainly temperature and relative humidity. It is important to characterise an archaeological site prior to carrying out comparative studies in the future for preventive conservation, either by regular studies to verify whether the conditions are constant, or occasional ones when the boundary conditions are altered. There are numerous covered archaeological sites, but few preventive conservation works that give special attention to the type of cover installed. In particular, there is no background of microclimatic studies in sites that are in the ground and, as in the Plaza de l’Almoina (Valencia, Spain), are buried and partially covered by a transparent roof. A large effect of the transparent cover was found by the sensors located below this area, with substantial increases in temperature and a decrease in the relative humidity during the day. Surrounding zones also have values above the recommended temperature values. On the other hand, the influence of a buried water drainage line near the site is notable, causing an increase in relative humidity levels in the surrounding areas. Multivariate statistical analyses enabled us to characterise the microclimate of the archaeological site, allowing future testing to determine whether the conservation conditions have been altered.

          Related collections

          Most cited references37

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Long-Term Monitoring of Fresco Paintings in the Cathedral of Valencia (Spain) Through Humidity and Temperature Sensors in Various Locations for Preventive Conservation

          We describe the performance of a microclimate monitoring system that was implemented for the preventive conservation of the Renaissance frescoes in the apse vault of the Cathedral of Valencia, that were restored in 2006. This system comprises 29 relative humidity (RH) and temperature sensors: 10 of them inserted into the plaster layer supporting the fresco paintings, 10 sensors in the walls close to the frescoes and nine sensors measuring the indoor microclimate at different points of the vault. Principal component analysis was applied to RH data recorded in 2007. The analysis was repeated with data collected in 2008 and 2010. The resulting loading plots revealed that the similarities and dissimilarities among sensors were approximately maintained along the three years. A physical interpretation was provided for the first and second principal components. Interestingly, sensors recording the highest RH values correspond to zones where humidity problems are causing formation of efflorescence. Recorded data of RH and temperature are discussed according to Italian Standard UNI 10829 (1999).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Microclimate monitoring of Ariadne’s house (Pompeii, Italy) for preventive conservation of fresco paintings

            Background Ariadne’s house, located at the city center of ancient Pompeii, is of great archaeological value due to the fresco paintings decorating several rooms. In order to assess the risks for long-term conservation affecting the valuable mural paintings, 26 temperature data-loggers and 26 relative humidity data-loggers were located in four rooms of the house for the monitoring of ambient conditions. Results Data recorded during 372 days were analyzed by means of graphical descriptive methods and analysis of variance (ANOVA). Results revealed an effect of the roof type and number of walls of the room. Excessive temperatures were observed during the summer in rooms covered with transparent roofs, and corrective actions were taken. Moreover, higher humidity values were recorded by sensors on the floor level. Conclusions The present work provides guidelines about the type, number, calibration and position of thermohygrometric sensors recommended for the microclimate monitoring of mural paintings in outdoor or semi-confined environments.
              Bookmark
              • Record: found
              • Abstract: not found
              • Book: not found

              Microclimate for cultural heritage

                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel)
                Sensors (Basel, Switzerland)
                Molecular Diversity Preservation International (MDPI)
                1424-8220
                August 2013
                29 July 2013
                : 13
                : 8
                : 9729-9746
                Affiliations
                [1 ] Departamento de Física Aplicada (U.D. Industriales), Universitat Politècnica de València, Av. de los Naranjos s/n, Valencia 46022, Spain; E-Mails: afnavajas@ 123456fis.upv.es (Á.F.-N.); palomamerello@ 123456outlook.com (P.M.); pbeltran@ 123456fis.upv.es (P.B.)
                [2 ] Instituto Valenciano de Conservación y Restauración de Bienes Culturales (IVC+R), Complejo Socio-Educativo de Penyeta Roja s/n, Castellón 12080, Spain
                [3 ] Centro de Tecnologías Físicas, Unidad Asociada ICMM- CSIC/UPV, Universitat Politècnica de València, Av. de los Naranjos s/n, Valencia 46022, Spain
                Author notes
                [†]

                All authors contributed equally to this work.

                [* ] Author to whom correspondence should be addressed; E-Mail: fjgarcid@ 123456upvnet.upv.es ; Tel.: +34-61-063-3671.
                Article
                sensors-13-09729
                10.3390/s130809729
                3812577
                23899937
                8071be36-23b2-4e18-8ee7-c1a221109049
                © 2013 by the authors; licensee MDPI, Basel, Switzerland.

                This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license ( http://creativecommons.org/licenses/by/3.0/).

                History
                : 25 June 2013
                : 16 July 2013
                : 23 July 2013
                Categories
                Article

                Biomedical engineering
                microclimate monitoring,archaeological preservation,temperature and relative humidity sensors

                Comments

                Comment on this article