36
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Assessment of insulin sensitivity/resistance

      other

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Insulin resistance is one pretty troublesome entity which very commonly aggravates metabolic syndrome. Many methods and indices are available for the estimation of insulin resistance. It is essential to test and validate their reliability before they can be used as an investigation in patients. At present, hyperinsulinemic euglycemic clamp and intravenous glucose tolerance test are the most reliable methods available for estimating insulin resistance and are being used as a reference standard. Some simple methods, from which indices can be derived, have been validated e.g. homeostasis model assessment (HOMA), quantitative insulin sensitivity check index (QUICKI). For the clinical uses HOMA-insulin resistance, QUIKI, and Matsuda are suitable, while HES, McAuley, Belfiore, Cederholm, Avignon and Stumvoll index are suitable for epidemiological/research purposes. With increasing number of these available indices of IR, it may be difficult for clinicians to select the most appropriate index for their studies. This review provides guidelines that must be considered before performing such studies.

          Related collections

          Most cited references9

          • Record: found
          • Abstract: found
          • Article: not found

          Insulin sensitivity indices obtained from oral glucose tolerance testing: comparison with the euglycemic insulin clamp.

          Several methods have been proposed to evaluate insulin sensitivity from the data obtained from the oral glucose tolerance test (OGTT). However, the validity of these indices has not been rigorously evaluated by comparing them with the direct measurement of insulin sensitivity obtained with the euglycemic insulin clamp technique. In this study, we compare various insulin sensitivity indices derived from the OGTT with whole-body insulin sensitivity measured by the euglycemic insulin clamp technique. In this study, 153 subjects (66 men and 87 women, aged 18-71 years, BMI 20-65 kg/m2) with varying degrees of glucose tolerance (62 subjects with normal glucose tolerance, 31 subjects with impaired glucose tolerance, and 60 subjects with type 2 diabetes) were studied. After a 10-h overnight fast, all subjects underwent, in random order, a 75-g OGTT and a euglycemic insulin clamp, which was performed with the infusion of [3-3H]glucose. The indices of insulin sensitivity derived from OGTT data and the euglycemic insulin clamp were compared by correlation analysis. The mean plasma glucose concentration divided by the mean plasma insulin concentration during the OGTT displayed no correlation with the rate of whole-body glucose disposal during the euglycemic insulin clamp (r = -0.02, NS). From the OGTT, we developed an index of whole-body insulin sensitivity (10,000/square root of [fasting glucose x fasting insulin] x [mean glucose x mean insulin during OGTT]), which is highly correlated (r = 0.73, P < 0.0001) with the rate of whole-body glucose disposal during the euglycemic insulin clamp. Previous methods used to derive an index of insulin sensitivity from the OGTT have relied on the ratio of plasma glucose to insulin concentration during the OGTT. Our results demonstrate the limitations of such an approach. We have derived a novel estimate of insulin sensitivity that is simple to calculate and provides a reasonable approximation of whole-body insulin sensitivity from the OGTT.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Glucose clamp technique: a method for quantifying insulin secretion and resistance.

            Methods for the quantification of beta-cell sensitivity to glucose (hyperglycemic clamp technique) and of tissue sensitivity to insulin (euglycemic insulin clamp technique) are described. Hyperglycemic clamp technique. The plasma glucose concentration is acutely raised to 125 mg/dl above basal levels by a priming infusion of glucose. The desired hyperglycemic plateau is subsequently maintained by adjustment of a variable glucose infusion, based on the negative feedback principle. Because the plasma glucose concentration is held constant, the glucose infusion rate is an index of glucose metabolism. Under these conditions of constant hyperglycemia, the plasma insulin response is biphasic with an early burst of insulin release during the first 6 min followed by a gradually progressive increase in plasma insulin concentration. Euglycemic insulin clamp technique. The plasma insulin concentration is acutely raised and maintained at approximately 100 muU/ml by a prime-continuous infusion of insulin. The plasma glucose concentration is held constant at basal levels by a variable glucose infusion using the negative feedback principle. Under these steady-state conditions of euglycemia, the glucose infusion rate equals glucose uptake by all the tissues in the body and is therefore a measure of tissue sensitivity to exogenous insulin.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              A model-based method for assessing insulin sensitivity from the oral glucose tolerance test.

              Available insulin sensitivity (IS) methods based on the oral glucose tolerance test (OGTT) are empirical. We used a glucose-insulin model to derive an OGTT-based IS (oral glucose insulin sensitivity [OGIS]) index, which predicts glucose clearance in a glucose clamp. We validated OGIS against clamp data. OGIS requires glucose and insulin concentrations from a 75-g OGTT at 0, 2, and 3 h (3-h OGTT) or at 0, 1.5, and 2 h (2-h OGTT). The formula includes six constants optimized to match the clamp results. For this purpose, 15 lean nondiabetic subjects (BMI 25 kg/m2), and 38 subjects with type 2 diabetes randomly underwent an OGTT and a 120 mU x min(-1) x m(-2) insulin infusion euglycemic clamp. Glucose clearance (Cl CLAMP), calculated as the ratio of glucose infusion to concentration during the last hour of the clamp, was compared with OGIS. OGIS was also tested on an independent group of 13 subjects with impaired glucose tolerance (IGT). OGIS and Cl CLAMP were correlated in the whole group (R = 0.77, P < 0.0001), in the subgroups (lean: R = 0.59; obese: R = 0.73; type 2 diabetes: R = 0.49; P < 0.02), and in the independent IGT group (R = 0.65, P < 0.02). Reproducibility of OGIS and Cl CLAMP were similar (coefficients of variation: OGIS 7.1%, Cl CLAMP 6.4%). OGIS was as effective as Cl CLAMP in discriminating between groups (for OGIS, lean vs. obese: 440 +/- 16 vs. 362 +/- 11 ml x min(-1) x m(-2), p < 0.001; lean vs. type 2 diabetes: 440 +/- 16 vs. 239 +/- 7, P < 0.0001; obese vs. type 2 diabetes: 362 +/- 11 vs. 239 +/- 7, P < 0.0001; results were similar for Cl CLAMP). The relationships between IS and BMI, fasting plasma insulin, and insulin secretion (calculated from the OGTT insulin concentration) were examined. OGIS yielded results similar to Cl CLAMP and fully consistent with established physiological principles. The performance of the index for the 3-h and 2-h OGTT was similar. OGIS is an index of IS in good agreement with the clamp. Because of its simplicity (only three blood samples required), this method has potential use for clinical investigation including large-scale epidemiological studies.
                Bookmark

                Author and article information

                Journal
                Indian J Endocrinol Metab
                Indian J Endocrinol Metab
                IJEM
                Indian Journal of Endocrinology and Metabolism
                Medknow Publications & Media Pvt Ltd (India )
                2230-8210
                2230-9500
                Jan-Feb 2015
                : 19
                : 1
                : 160-164
                Affiliations
                [1] Department of Endocrinology, LLRM Medical College, Meerut, Uttar Pradesh, India
                [1 ] Department of Radiodiagnosis, SGPGI, Lucknow, Uttar Pradesh, India
                Author notes
                Corresponding Author: Dr. Manish Gutch, D-15, LLRM Medical College, Meerut - 250 004, Uttar Pradesh, India. E-mail: manish07gutch@ 123456gmail.com
                Article
                IJEM-19-160
                10.4103/2230-8210.146874
                4287763
                25593845
                82d2d192-3894-4917-b403-369424996d2c
                Copyright: © Indian Journal of Endocrinology and Metabolism

                This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                Categories
                Brief Communication

                Endocrinology & Diabetes
                homeostasis model assessment,hyperinsulinemic euglycemic clamp,insulin sensitivity,quantitative insulin sensitivity check index

                Comments

                Comment on this article