          Reliability of isometric, isokinetic and isoinertial modalities for quadriceps strength evaluation, and the relation between quadriceps strength and physical function was investigated in 29 total knee arthroplasty (TKA) patients, with an average age of 63 years. Isometric maximal voluntary contraction torque, isokinetic peak torque, and isoinertial one-repetition maximum load of the involved and uninvolved quadriceps were evaluated as well as objective (walking parameters) and subjective physical function (WOMAC). Reliability was good and comparable for the isometric, isokinetic, and isoinertial strength outcomes on both sides (intraclass correlation coefficient range: 0.947-0.966; standard error of measurement range: 5.1-9.3%). Involved quadriceps strength was significantly correlated to walking speed (r range: 0.641-0.710), step length (r range: 0.685-0.820) and WOMAC function (r range: 0.575-0.663), independent from the modality (P < 0.05). Uninvolved quadriceps strength was also significantly correlated to walking speed (r range: 0.413-0.539), step length (r range: 0.514-0.608) and WOMAC function (r range: 0.374-0.554) (P < 0.05), except for WOMAC function/isokinetic peak torque (P > 0.05). In conclusion, isometric, isokinetic, and isoinertial modalities ensure valid and reliable assessment of quadriceps muscle strength in TKA patients.

          Related collections

          Author and article information

          Journal
          J Electromyogr Kinesiol
          Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
          1873-5711
          1050-6411
          Dec 2013
          : 23
          : 6
          Affiliations
          [1 ] Neuromuscular Research Laboratory, Schulthess Clinic, Zurich, Switzerland; Institute of Human Movement Sciences and Sport, ETH, Zurich, Switzerland; Laboratory of Human Motricity, Education, Sport and Health (LAMHESS) - EA 6309, University of Nice Sophia Antipolis, Nice, France.