33
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Long-Term Durability and Comfort of Laparoscopic Ventral Hernia Repair

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Laparoscopic ventral hernia repair with carboxymethylcellulose-sodium hyaluronate coating appears to be safe, effective, and durable.

          Abstract

          Background:

          Repair of ventral hernias, including primary ventral hernias and incisional ventral hernias, is performed in the United States 90,000 times per year. Open or traditional ventral hernia repairs involve the significant morbidity and expense of a laparotomy and a significant risk of recurrent herniation. Laparoscopic ventral hernia repair (LVHR) may offer a less-invasive alternative with shorter length of hospital stay, fewer cardiopulmonary complications, and low recurrence rates.

          Methods:

          225 patients underwent laparoscopic ventral hernia repairs in which carboxymethylcellulose-sodium hyaluronate coating (Sepramesh, Davol, Providence, RI) was used primarily. All cases were included prospectively from the study period of 2002 through 2009. Patient characteristics were recorded, and follow-up analysis was performed over a period of 42 mo following surgery. Recurrence, reoperations, and all complications were recorded. Mesh awareness and mesh-related pain were assessed using the hernia-specific Carolinas Comfort Scale (CCS) instrument, completed by 72 patients.

          Results:

          Over 42 mo of follow-up, 2 ventral hernias have recurred, and no long-term bowel erosion or fistulization has occurred. Little or no mesh-related symptoms were reported, and mean scores for mesh awareness and mesh pain were 3.6 and 3.2, respectively, on a scale from 0–40 (lower scores signify less pain or awareness). Two serious early complications occurred related to intestinal ileus and metal tacks producing intestinal perforation, and this led to a change in the tacking devices used.

          Conclusions:

          LVHR with carboxymethylcellulose-sodium hyaluronate coating (Sepramesh) is safe and effective. Complications are rare, the repair is durable, and long-term results are good with rare recurrences, low awareness of mesh, and little pain. Technical lessons include use of at least one transfascial suture and the avoidance of metal tacks for fixation.

          Related collections

          Most cited references17

          • Record: found
          • Abstract: found
          • Article: not found

          Long-term complications associated with prosthetic repair of incisional hernias.

          To determine whether the type of prosthetic material and technique of placement influenced long-term complications after repair of incisional hernias. Retrospective cohort analytic study. University-affiliated hospital. Two hundred patients undergoing open repair of abdominal incisional hernias with prosthetic material between 1985 and 1994. Four types of prosthetic material were used and placed either as an onlay, underlay, sandwich, or finger interdigitation technique. The materials were monofilamented polypropylene mesh (Marlex, Davol Inc, Cranston, RI), double-filamented mesh (Prolene, Ethicon Inc, Somerville, NJ), expanded polytetrafluroethylene patch (Gore-Tex, WL Gore & Associates, Phoenix, Ariz) or multifilamented polyester mesh (Mersilene, Ethicon Inc). The incidence of recurrence and complications such as enterocutaneous fistula, bowel obstruction, and infection with each type of material and technique of repair were compared with univariate and multivariate analysis. On univariate analysis, multifilamented polyester mesh had a significantly higher mean number of complications per patient (4.7 vs 1.4-2.3; P<.002), a higher incidence of fistula formation (16% vs 0%-2%; P<.001), a greater number of infections (16% vs 0%-6%; P<.05), and more recurrent hernias (34% vs 10%-14%; P<.05) than the other materials used. The additional mean length of stay to treat complications was also significantly longer (30 vs 3-7 days; P<.001) when polyester mesh was used. The deleterious effect of polyester mesh on long-term complications was confirmed on multiple logistic regression (P=.002). The technique of placement had no influence on outcome. Polyester mesh should no longer be used for incisional hernia repair.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Laparoscopic repair of ventral hernias: nine years' experience with 850 consecutive hernias.

            To evaluate the efficacy and safety of laparoscopic repair of ventral hernias. The recurrence rate after standard repair of ventral hernias may be as high as 12-52%, and the wide surgical dissection required often results in wound complications. Use of a laparoscopic approach may decrease rates of complications and recurrence after ventral hernia repair. Data on all patients who underwent laparoscopic ventral hernia repair (LVHR) performed by 4 surgeons using a standardized procedure between November 1993 and October 2002 were collected prospectively (85% of patients) or retrospectively. LVHR was completed in 819 of the 850 patients (422 men; 428 women) in whom it was attempted. Thirty-four percent of completed LVHRs were for recurrent hernias. The patient mean body mass index was 32; the mean defect size was 118 cm2. Mesh, averaging 344 cm2, was used in all cases. Mean operating time was 120 min, mean estimated blood loss was 49 mL, and hospital stay averaged 2.3 days. There were 128 complications in 112 patients (13.2%). One patient died of a myocardial infarction. The most common complications were ileus (3%) and prolonged seroma (2.6%). During a mean follow-up time of 20.2 months (range, 1-94 months), the hernia recurrence rate was 4.7%. Recurrence was associated with large defects, obesity, previous open repairs, and perioperative complications. In this large series, LVHR had a low rate of conversion to open surgery, a short hospital stay, a moderate complication rate, and a low risk of recurrence.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Comparison of generic versus specific quality-of-life scales for mesh hernia repairs.

              With the use of mesh shown to considerably reduce recurrence rates for hernia repair and the subsequent improvement in clinical outcomes, focus has now been placed on quality-of-life outcomes in patients undergoing these repairs, specifically, as they relate to the mesh prosthesis. Traditionally, quality of life after hernia surgery, like many other medical conditions, has been tested using the generic SF-36 survey. The SF-36 quality-of-life survey, although well studied and validated, may not be ideal for patients undergoing hernia repairs. We propose a new quality-of-life survey, the Carolinas Comfort Scale (CCS), pertaining specifically to patients undergoing hernia repair with mesh; our goal was to test the validity and reliability of this survey. The CCS questionnaire was mailed to 1,048 patients to assess its acceptability, responsiveness, and psychometric properties. The survey sample included patients who were at least 6 months out after hernia repair with mesh. Patients were asked to fill out the CCS and the generic SF-36 questionnaires, four questions comparing the two surveys, and their overall satisfaction relating to their hernia repair and mesh. The reliability of the CCS was confirmed by Cronbach's alpha coefficient (0.97). Test-retest validity was supported by the correlation found between two different administrations of the CCS; both Spearman's correlation coefficient and the kappa coefficient were important for each question of the CCS. Assessment of its discriminant validity showed that both the mean and median scores for satisfied patients were considerably lower than those for dissatisfied patients. Concurrent validity was demonstrated by the marked correlations found between the CCS and SF-36 questionnaire scales. When comparing the two surveys, 72% of patients preferred the CCS questionnaire, 80% believed it was easier to understand, 66% thought it was more reflective of their condition, and 69% said they would rather fill it out over the SF-36. The CCS better assesses quality of life and satisfaction of patients who have undergone surgical hernia repair than the generic SF-36.
                Bookmark

                Author and article information

                Journal
                JSLS
                JSLS
                jsls
                jsls
                JSLS
                JSLS : Journal of the Society of Laparoendoscopic Surgeons
                Society of Laparoendoscopic Surgeons (Miami, FL )
                1086-8089
                1938-3797
                Jul-Sep 2012
                : 16
                : 3
                : 380-386
                Affiliations
                Western Bariatric Institute, Reno, NV, USA.
                Author notes
                Address correspondence to: Dionne Lim, 645 N. Arlington Ave, Suite 525, Reno, NV 89503, USA. Telephone: (775) 772-6880, Fax: (775) 789-4191, E-mail: dlim@ 123456westernsurgical.com
                Article
                10-09-127
                10.4293/108680812X13462882736097
                3535804
                23318062
                8fc756c2-b244-409b-959e-f967e4db44dc
                © 2012 by JSLS, Journal of the Society of Laparoendoscopic Surgeons.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License ( http://creativecommons.org/licenses/by-nc-nd/3.0/us/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way.

                History
                Categories
                Scientific Papers

                Surgery
                sepramesh,polypropylene,mesh,ventral hernia,incisional hernia,laparoscopic surgery,laparoscopic ventral hernia repair

                Comments

                Comment on this article