      The Reliability of Automated Three-Dimensional Echocardiography-HeartModel A.I. Versus 2D Echocardiography Simpson Methods in Evaluation of Left Ventricle Volumes and Ejection Fraction in Patients With Left Ventricular Dysfunction

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background:

          Two-dimensional echocardiography (2DE) Simpson methods is the most frequently used imaging modality to assess Left ventricular ejection fraction (LVEF). LVEF is an important predictor of morbidity and mortality in a wide range of patients and clinical scenarios. Despite its importance in prognosis and clinical decision making, most echocardiography laboratories currently determine EF primarily by visual estimation, which is highly experience-dependent and sensitive to intra- and inter-observer variability and suboptimal accuracy and repeatability. Over the last decade, 3-dimensional echocardiography (3DE) has become increasingly implemented in clinical practice. The automated 3D HeartModel A.I. tracks every frame over the cardiac cycle using 3D speckle technology. HeartModel A.I. is a fully automated program that simultaneously detects LA and LV endocardial surfaces using an adaptive analytics algorithm that consists of knowledge-based identification of initial global shape and orientation followed by patient-specific adaptation.

          Objective:

          The objective of the study was to compare the automated 3D HeartModel A.I echocardiography and 2D Simpson methods echocardiography in evaluation of the left ventricular ejection fraction and left ventricular volumes in patients with left heart dysfunction.

          Methods:

          The study prospectively enrolled 165 patients with symptoms of LV dysfunction (ischemic or nonischemic) and New York Heart Association (NYHA) functional class I-III, referred for an echocardiographic study to evaluate the LV volumes and LV ejection fraction (LVEF) during the period from March 2020 to March 2022. Echocardiographic images were acquired by experienced echocardiographers using a commercially available Philips EPIQ machine (Koninklijke Philips Ultrasound, USA) equipped with X5-1 Matrix probe for 2DE and DHM 3DE acquisitions, respectively.

          Results:

          2D Simpson methods echocardiography results for estimated LVEF were 38.43 ± 1.70 in patients with NYHA class I-II, 30.53 ± 1.60 in patients with NYHA class III. Using 3D Heart Model, LVEF were 38.23 ± 1.71 in patients with NYHA class I-II and 30.27 ± 1.50 in patients with NYHA class III. The results of 2D Simpson methods echocardiography for estimated LVEDVi in NYHA class I-II and NYHA class III were 99.06 ± 6.36 ml/m2, 121.96 ± 2.93 ml/m2 respectively, LVESVi were 60.91 ± 3.91 ml/m2, 84.74 ± 2.70 ml/m2 respectively, for 3D Heart Model, LVEDVi in NYHA class I-II and NYHA class III were 100.07 ± 6.72, 121.38 ± 3.01 ml/m2 respectively, LVESVi were 61.75 ± 3.94 ml/m2, 84.73 ± 2.33 ml/m2 respectively. 2DE measurement of LV volumes and EF was completed in 6.1 ± 0.8 min. per patient. 3DE HeartModel A.I acquisition and analysis in most patients was completed in <3.2 min., an average time of 2.9 ± 1.3 min. per patient. The result of our study shows that the 3D HeartModel A.I. is a reliable and robust method for LVEF and LV volume analysis, which has similar results to 2D echocardiography performed by experienced sonographers. In this study, we found that 3DE DHM fully automated tool is also significantly faster than 2DE analysis and thus can help overcome the time-consuming nature and its present a strong argument for its incorporation into the clinical workflow. In this study, we found that 3DE DHM fully automated tool is also significantly faster than 2DE analysis and thus can help overcome the time-consuming nature and its present a strong argument for its incorporation into the clinical workflow.

          Conclusion:

          3D DHM provides fast and accurate LV volumes and LVEF quantitation, as it avoids geometric assumptions and left ventricular foreshortening, has better reproducibility and has incremental value to predict adverse outcomes in comparison with conventional 2DE. In the future major benefit of AI in echocardiography is expected from improvements in automated analysis and interpretation to reduce workload and improve clinical outcome.

          Related collections

          Most cited references28

          • Record: found
          • Abstract: not found
          • Article: not found

          2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging.

            The rapid technological developments of the past decade and the changes in echocardiographic practice brought about by these developments have resulted in the need for updated recommendations to the previously published guidelines for cardiac chamber quantification, which was the goal of the joint writing group assembled by the American Society of Echocardiography and the European Association of Cardiovascular Imaging. This document provides updated normal values for all four cardiac chambers, including three-dimensional echocardiography and myocardial deformation, when possible, on the basis of considerably larger numbers of normal subjects, compiled from multiple databases. In addition, this document attempts to eliminate several minor discrepancies that existed between previously published guidelines.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              2017 AHA/ACC/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death

                Bookmark

                Author and article information

                Journal
                Med Arch
                Med Arch
                Medical Archives
                Medical Archives
                Academy of Medical Sciences of Bosnia and Herzegovina
                0350-199X
                1986-5961
                August 2022
                : 76
                : 4
                : 259-266
                Affiliations
                [1 ]Polyclinic „Dr. Nabil”, Sarajevo, Bosnia and Herzegovina.
                [2 ]Faculty of Medicine, University of Sarajevo, Bosnia and Herzegovina
                [3 ]Department of Cardiology, Clinical Hospital Centre Zemun.
                [4 ]Faculty of Medicine, University of Belgrade, Serbia
                Author notes
                Corresponding author: Assoc. Prof. Nabil Naser, MD, PhD, FACC, FESC, FEACVI. Polyclinic “Dr. Nabil”, Sarajevo, Bosnia and Herzegovina. +387 33 777 711 +38733 777 710 nabil@ 123456bih.net.ba ORCID ID: http://www.orcid.org/0000-0002-278-8574.
                Article
                10.5455/medarh.2022.76.259-266
                9559669
                36313951
                8fe08e94-a009-440e-8cdd-fd8152e3b406
                © 2022 Nabil Naser, Ivan Stankovic, Aleksandar Neskovic

                This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ( http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 12 July 2022
                : 14 August 2022
                Categories
                Original Paper

                2d simpson methods echocardiography,3d heartmodel,a.i echocardiography,left ventricle ejection fraction (lvef),left ventricular dysfunction

                Comments

                Comment on this article