20
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Estudo comparativo dos resultados das provas da prono-posição em quarto escuro em indivíduos sentados e em decúbito horizontal ventral Translated title: Comparative analysis of the results of dark room prone provocative test of patients in sitting and ventral decubitus positions

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          RESUMO Objetivo: Investigar os resultados das provas de prono-posição em quarto escuro (PPQE) em indivíduos sentados e em decúbito horizontal ventral. Material e Métodos: Foram estudados 30 olhos de 15 pacientes portadores de glaucoma. As provas da PPQE foram realizadas nas duas posições (sentado e deitado) com intervalo de 24 horas. Resultados: A média e o desvio padrão da diferença entre as pressões intra-oculares finais e iniciais, do olho direito na posição sentado foi de 4,13 ± 1,77 mmHg e na posição de decúbito horizontal ventral foi de 4,40 ± 2,33 mmHg. No olho esquerdo na posição sentado foi de 4,13 ± 1,69 mmHg e na posição de decúbito horizontal ventral foi de 4,47 ± 2,07 mmHg. Conclusão: Não foram encontradas diferenças estatisticamente significantes, entre as posições sentado e em decúbito horizontal ventral, nos resultados da PPQE.

          Translated abstract

          SUMMARY Purpose: To evaluate the dark room prone provocative test in patients in the sitting and horizontal positions. Material and Methods: We studied 30 eyes of 15 patients with glaucoma. The tests were performed in a 24-hour interval. Results: The mean and standard deviation of the difference of IOP between the beginning and end when in the sitting position was 4.13 ± 1.77 mmHg and in the horizontal position it was 4.40 ± 2.33 mmHg for the right eye and for the left eye it was 4.13 ± 1.69 mmHg and 4.47 ± 2.07 mmHg respectively. Conclusion: There were no statistical differences between both positions.

          Related collections

          Most cited references7

          • Record: found
          • Abstract: not found
          • Article: not found

          Reprodutibilidade do Teste de Prono-posição em quarto escuro

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Primary angle-closure glaucoma. A review of provocative tests

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Positividade do Teste de Prono-posição em quarto escuro

                Bookmark

                Author and article information

                Contributors
                Role: ND
                Role: ND
                Journal
                abo
                Arquivos Brasileiros de Oftalmologia
                Arq. Bras. Oftalmol.
                Conselho Brasileiro de Oftalmologia (São Paulo, SP, Brazil )
                0004-2749
                1678-2925
                June 1999
                : 62
                : 3
                : 280-284
                Affiliations
                [2] orgnameUniversidade de São Paulo orgdiv1Faculdade Medicina orgdiv2Hospital das Clínicas Brazil
                [1] orgnameUniversidade de São Paulo orgdiv1Faculdade Medicina orgdiv2Hospital das Clínicas Brazil
                Article
                S0004-27491999000300280
                10.5935/0004-2749.19990013
                90fe1a4c-73ad-4597-b871-99b2abee73e9

                This work is licensed under a Creative Commons Attribution 4.0 International License.

                History
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 8, Pages: 5
                Product

                SciELO Brazil


                Prone provocative test,Glaucoma,Intraocular pressure,Teste provocativo,Pressão intra-ocular

                Comments

                Comment on this article