          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Ebola outbreak-2014 (mainly Zaire strain related Ebola virus) has been declared most widely spread deadly persistent epidemic due to unavailability of rapid diagnostic, detection, and therapeutics. Ebola virus disease (EVD), a severe viral hemorrhagic fever syndrome caused by Ebola virus (EBOV) is transmitted by direct contact with the body fluids of infected person and objects contaminated with virus or infected animals. World Health Organization (WHO) has declared EVD epidemic as public health emergency of international concern with severe global economic burden. At fatal EBOV infection stage, patients usually die before the antibody response. Currently, rapid blood tests to diagnose EBOV infection include the antigen or antibodies capture using ELISA and RNA detection using RT/Q-PCR within 3–10 days after the onset of symptoms. Moreover, few nanotechnology-based colorimetric and paper-based immunoassay methods have been recently reported to detect Ebola virus. Unfortunately, these methods are limited to laboratory only. As state-of-the art (SoA) diagnostics time to confirm Ebola infection, varies from 6 h to about 3 days, it causes delay in therapeutic approaches. Thus developing a cost-effective, rapid, sensitive, and selective sensor to detect EVD at point-of-care (POC) is certainly worth exploring to establish rapid diagnostics to decide therapeutics. This review highlights SoA of Ebola diagnostics and also a call to develop rapid, selective and sensitive POC detection of EBOV for global health care. We propose that adopting miniaturized electrochemical EBOV immunosensing can detect virus level at pM concentration within ∼40 min compared to 3 days of ELISA test at nM levels.

          Highlights

          • EVD is deadly persistent epidemic due to unavailability of rapid diagnosis and therapeutics.

          • Unfortunately, available EVD detection tools are limited to laboratory only.

          • Thus developing efficient e sensor to detect EVD at point-of-care is needed.

          • For rapid detection, we propose electrochemical Ebola virus sensing as possible solution.

          • These sensors can detect virus level at pM concentration within ∼40 min.

          Related collections

          Most cited references73

          • Record: found
          • Abstract: found
          • Article: not found

          Rapid detection and quantification of RNA of Ebola and Marburg viruses, Lassa virus, Crimean-Congo hemorrhagic fever virus, Rift Valley fever virus, dengue virus, and yellow fever virus by real-time reverse transcription-PCR.

          Viral hemorrhagic fevers (VHFs) are acute infections with high case fatality rates. Important VHF agents are Ebola and Marburg viruses (MBGV/EBOV), Lassa virus (LASV), Crimean-Congo hemorrhagic fever virus (CCHFV), Rift Valley fever virus (RVFV), dengue virus (DENV), and yellow fever virus (YFV). VHFs are clinically difficult to diagnose and to distinguish; a rapid and reliable laboratory diagnosis is required in suspected cases. We have established six one-step, real-time reverse transcription-PCR assays for these pathogens based on the Superscript reverse transcriptase-Platinum Taq polymerase enzyme mixture. Novel primers and/or 5'-nuclease detection probes were designed for RVFV, DENV, YFV, and CCHFV by using the latest DNA database entries. PCR products were detected in real time on a LightCycler instrument by using 5'-nuclease technology (RVFV, DENV, and YFV) or SybrGreen dye intercalation (MBGV/EBOV, LASV, and CCHFV). The inhibitory effect of SybrGreen on reverse transcription was overcome by initial immobilization of the dye in the reaction capillaries. Universal cycling conditions for SybrGreen and 5'-nuclease probe detection were established. Thus, up to three assays could be performed in parallel, facilitating rapid testing for several pathogens. All assays were thoroughly optimized and validated in terms of analytical sensitivity by using in vitro-transcribed RNA. The >or=95% detection limits as determined by probit regression analysis ranged from 1,545 to 2,835 viral genome equivalents/ml of serum (8.6 to 16 RNA copies per assay). The suitability of the assays was exemplified by detection and quantification of viral RNA in serum samples of VHF patients.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Development of a preventive vaccine for Ebola virus infection in primates.

            Outbreaks of haemorrhagic fever caused by the Ebola virus are associated with high mortality rates that are a distinguishing feature of this human pathogen. The highest lethality is associated with the Zaire subtype, one of four strains identified to date. Its rapid progression allows little opportunity to develop natural immunity, and there is currently no effective anti-viral therapy. Therefore, vaccination offers a promising intervention to prevent infection and limit spread. Here we describe a highly effective vaccine strategy for Ebola virus infection in non-human primates. A combination of DNA immunization and boosting with adenoviral vectors that encode viral proteins generated cellular and humoral immunity in cynomolgus macaques. Challenge with a lethal dose of the highly pathogenic, wild-type, 1976 Mayinga strain of Ebola Zaire virus resulted in uniform infection in controls, who progressed to a moribund state and death in less than one week. In contrast, all vaccinated animals were asymptomatic for more than six months, with no detectable virus after the initial challenge. These findings demonstrate that it is possible to develop a preventive vaccine against Ebola virus infection in primates.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Ebola virus entry requires the host-programmed recognition of an intracellular receptor.

              Ebola and Marburg filoviruses cause deadly outbreaks of haemorrhagic fever. Despite considerable efforts, no essential cellular receptors for filovirus entry have been identified. We showed previously that Niemann-Pick C1 (NPC1), a lysosomal cholesterol transporter, is required for filovirus entry. Here, we demonstrate that NPC1 is a critical filovirus receptor. Human NPC1 fulfills a cardinal property of viral receptors: it confers susceptibility to filovirus infection when expressed in non-permissive reptilian cells. The second luminal domain of NPC1 binds directly and specifically to the viral glycoprotein, GP, and a synthetic single-pass membrane protein containing this domain has viral receptor activity. Purified NPC1 binds only to a cleaved form of GP that is generated within cells during entry, and only viruses containing cleaved GP can utilize a receptor retargeted to the cell surface. Our findings support a model in which GP cleavage by endosomal cysteine proteases unmasks the binding site for NPC1, and GP-NPC1 engagement within lysosomes promotes a late step in entry proximal to viral escape into the host cytoplasm. NPC1 is the first known viral receptor that recognizes its ligand within an intracellular compartment and not at the plasma membrane.
                Bookmark

                Author and article information

                Contributors
                Journal
                Biosens Bioelectron
                Biosens Bioelectron
                Biosensors & Bioelectronics
                Elsevier B.V.
                0956-5663
                1873-4235
                20 August 2015
                15 January 2016
                20 August 2015
                : 75
                : 254-272
                Affiliations
                [a ]Center for Personalized Nanomedicine, Institute of NeuroImmune Pharmacology, Department of Immunology, Florida International University, Miami, USA
                [b ]Infectious Diseases, Department of Medicine, Herbert Wertheim College of Medicine, Florida International University, Miami, USA
                Author notes
                Article
                S0956-5663(15)30365-1
                10.1016/j.bios.2015.08.040
                4601610
                26319169
                939a29fb-2d05-41a2-9689-4ef757eb0716
                Copyright © 2015 Elsevier B.V. All rights reserved.

                Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.

                History
                : 25 June 2015
                : 18 August 2015
                : 19 August 2015
                Categories
                Article

                Biomedical engineering
                ebola virus diseases,ebola therapeutics,ebola diagnostics,ebola sensor,point-of-care sensing

                Comments

                Comment on this article