7
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Electric toothbrush for biofilm control in individuals with Down syndrome: a crossover randomized clinical trial

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Abstract Poor oral hygiene seems to be the norm in children and teenagers with Down Syndrome (DS). Advances in design and types of toothbrushes may improve biofilm control. This randomized, single-blind, crossover clinical trial evaluated the effectiveness of electric toothbrushes regarding mechanical control of biofilm in children and teenagers with DS and their cooperation. Twenty-nine participants with DS, aged 6 to 14 years, used both types of toothbrushes: electric (ET) and manual (MT). The order of use of the different types of toothbrushes was randomly defined, including a 7-day period with each type with 7-day washout period in between. The Turesky-Quigley-Hein biofilm index was used before and after brushing to assess the effectiveness of the technique. Frankl’s behavioral scale was used during toothbrushing to assess the participants’ cooperation. Paired T-test, Mann Whitney, Chi-square, and Fisher’s Exact tests were applied, with a significance level of 5%. The quantity of dental biofilm was significantly reduced after both brushing techniques (p < 0.001). However, no significant difference was found in total biofilm (ET: 0.73 ± 0.36; MT: 0.73 ± 0.34; p = 0.985) or % biofilm reduction (ET: 72.22%; MT: 70.96%; p = 0.762) after brushing between techniques or in % biofilm reduction between toothbrushes of age groups (6 –9 years, p = 0.919; 10–14 years, p = 0.671). Participants showed similar cooperation level with the two types of toothbrush (p = 1.000). The use of electric or manual toothbrush had no effect on the quantity of dental biofilm removed in children and teenagers with DS, nor did it influence their cooperation during the procedure.

          Related collections

          Most cited references35

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Non-invasive prenatal assessment of trisomy 21 by multiplexed maternal plasma DNA sequencing: large scale validity study

          Objectives To validate the clinical efficacy and practical feasibility of massively parallel maternal plasma DNA sequencing to screen for fetal trisomy 21 among high risk pregnancies clinically indicated for amniocentesis or chorionic villus sampling. Design Diagnostic accuracy validated against full karyotyping, using prospectively collected or archived maternal plasma samples. Setting Prenatal diagnostic units in Hong Kong, United Kingdom, and the Netherlands. Participants 753 pregnant women at high risk for fetal trisomy 21 who underwent definitive diagnosis by full karyotyping, of whom 86 had a fetus with trisomy 21. Intervention Multiplexed massively parallel sequencing of DNA molecules in maternal plasma according to two protocols with different levels of sample throughput: 2-plex and 8-plex sequencing. Main outcome measures Proportion of DNA molecules that originated from chromosome 21. A trisomy 21 fetus was diagnosed when the z score for the proportion of chromosome 21 DNA molecules was >3. Diagnostic sensitivity, specificity, positive predictive value, and negative predictive value were calculated for trisomy 21 detection. Results Results were available from 753 pregnancies with the 8-plex sequencing protocol and from 314 pregnancies with the 2-plex protocol. The performance of the 2-plex protocol was superior to that of the 8-plex protocol. With the 2-plex protocol, trisomy 21 fetuses were detected at 100% sensitivity and 97.9% specificity, which resulted in a positive predictive value of 96.6% and negative predictive value of 100%. The 8-plex protocol detected 79.1% of the trisomy 21 fetuses and 98.9% specificity, giving a positive predictive value of 91.9% and negative predictive value of 96.9%. Conclusion Multiplexed maternal plasma DNA sequencing analysis could be used to rule out fetal trisomy 21 among high risk pregnancies. If referrals for amniocentesis or chorionic villus sampling were based on the sequencing test results, about 98% of the invasive diagnostic procedures could be avoided.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Reduced Plaque Formation by the Chloromethyl Analogue of Victamine C

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Comparative cleansing efficiency of manual and power brushing

                Bookmark

                Author and article information

                Journal
                bor
                Brazilian Oral Research
                Braz. oral res.
                Sociedade Brasileira de Pesquisa Odontológica - SBPqO (São Paulo, SP, Brazil )
                1806-8324
                1807-3107
                2020
                : 34
                : e057
                Affiliations
                [2] Teresina Piauí orgnameUniversidade Federal do Piauí orgdiv1Department of Restorative Dentistry Brazil
                [1] Teresina Piauí orgnameUniversidade Federal do Piauí orgdiv1Postgraduation Program in Dentistry Brazil
                Article
                S1806-83242020000100244 S1806-8324(20)03400000244
                10.1590/1807-3107bor-2020.vol34.0057
                96b292ef-8a50-47c3-8315-0354a7449bb4

                This work is licensed under a Creative Commons Attribution 4.0 International License.

                History
                : 07 April 2020
                : 18 April 2019
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 40, Pages: 0
                Product

                SciELO Brazil

                Self URI: Full text available only in PDF format (EN)
                Categories
                Original Research

                Behavior,Toothbrushing,Clinical Trial,Down Syndrome
                Behavior, Toothbrushing, Clinical Trial, Down Syndrome

                Comments

                Comment on this article