5
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Effects of Arrangement of UV Light-Emitting Diodes on the Inactivation Efficiency of Microorganisms in Water

      1 , 2 , 2
      Photochemistry and Photobiology
      Wiley

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references9

          • Record: found
          • Abstract: found
          • Article: not found

          Inactivation credit of UV radiation for viruses, bacteria and protozoan (oo)cysts in water: a review.

          UV disinfection technology is of growing interest in the water industry since it was demonstrated that UV radiation is very effective against (oo)cysts of Cryptosporidium and Giardia, two pathogenic micro-organisms of major importance for the safety of drinking water. Quantitative Microbial Risk Assessment, the new concept for microbial safety of drinking water and wastewater, requires quantitative data of the inactivation or removal of pathogenic micro-organisms by water treatment processes. The objective of this study was to review the literature on UV disinfection and extract quantitative information about the relation between the inactivation of micro-organisms and the applied UV fluence. The quality of the available studies was evaluated and only high-quality studies were incorporated in the analysis of the inactivation kinetics. The results show that UV is effective against all waterborne pathogens. The inactivation of micro-organisms by UV could be described with first-order kinetics using fluence-inactivation data from laboratory studies in collimated beam tests. No inactivation at low fluences (offset) and/or no further increase of inactivation at higher fluences (tailing) was observed for some micro-organisms. Where observed, these were included in the description of the inactivation kinetics, even though the cause of tailing is still a matter of debate. The parameters that were used to describe inactivation are the inactivation rate constant k (cm(2)/mJ), the maximum inactivation demonstrated and (only for bacterial spores and Acanthamoeba) the offset value. These parameters were the basis for the calculation of the microbial inactivation credit (MIC="log-credits") that can be assigned to a certain UV fluence. The most UV-resistant organisms are viruses, specifically Adenoviruses, and bacterial spores. The protozoon Acanthamoeba is also highly UV resistant. Bacteria and (oo)cysts of Cryptosporidium and Giardia are more susceptible with a fluence requirement of <20 mJ/cm(2) for an MIC of 3 log. Several studies have reported an increased UV resistance of environmental bacteria and bacterial spores, compared to lab-grown strains. This means that higher UV fluences are required to obtain the same level of inactivation. Hence, for bacteria and spores, a correction factor of 2 and 4 was included in the MIC calculation, respectively, whereas some wastewater studies suggest that a correction of a factor of 7 is needed under these conditions. For phages and viruses this phenomenon appears to be of little significance and for protozoan (oo)cysts this aspect needs further investigation. Correction of the required fluence for DNA repair is considered unnecessary under the conditions of drinking water practice (no photo-repair, dark repair insignificant, esp. at higher (60 mJ/cm(2)) fluences) and probably also wastewater practice (photo-repair limited by light absorption). To enable accurate assessment of the effective fluence in continuous flow UV systems in water treatment practice, biodosimetry is still essential, although the use of computational fluid dynamics (CFD) improves the description of reactor hydraulics and fluence distribution. For UV systems that are primarily dedicated to inactivate the more sensitive pathogens (Cryptosporidium, Giardia, pathogenic bacteria), additional model organisms are needed to serve as biodosimeter.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Application of GaN-based ultraviolet-C light emitting diodes--UV LEDs--for water disinfection.

            GaN-based ultraviolet-C (UV-C) light emitting diodes (LEDs) are of great interest for water disinfection. They offer significant advantages compared to conventional mercury lamps due to their compact form factor, low power requirements, high efficiency, non-toxicity, and overall robustness. However, despite the significant progress in the performance of semiconductor based UV LEDs that has been achieved in recent years, these devices still suffer from low emission power and relatively short lifetimes. Even the best UV LEDs exhibit external quantum efficiencies of only 1-2%. The objective of this study was to investigate the suitability of GaN-based UV LEDs for water disinfection. The investigation included the evaluation of the performance characteristics of UV LEDs at different operating conditions as well as the design of a UV LED module in view of the requirements for water treatment applications. Bioanalytical testing was conducted using Bacillus subtilis spores as test organism and UV LED modules with emission wavelengths of 269 nm and 282 nm. The results demonstrate the functionality of the developed UV LED disinfection modules. GaN-based UV LEDs effectively inactivated B. subtilis spores during static and flow-through tests applying varying water qualities. The 269 nm LEDs reached a higher level of inactivation than the 282 nm LEDs for the same applied fluence. The lower inactivation achieved by the 282 nm LEDs was compensated by their higher photon flux. First flow-through tests indicate a linear correlation between inactivation and fluence, demonstrating a well designed flow-through reactor. With improved light output and reduced costs, GaN-based UV LEDs can provide a promising alternative for decentralised and mobile water disinfection systems.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Application of UV light emitting diodes to batch and flow-through water disinfection systems

                Bookmark

                Author and article information

                Journal
                Photochemistry and Photobiology
                Photochem Photobiol
                Wiley
                00318655
                March 2016
                March 2016
                March 01 2016
                : 92
                : 2
                : 314-317
                Affiliations
                [1 ]Research Center for Advanced Science and Technology; The University of Tokyo; Tokyo Japan
                [2 ]Department of Urban Engineering; The University of Tokyo; Tokyo Japan
                Article
                10.1111/php.12571
                a0a1fc9a-c2a1-463b-8cf0-9b297a353bfb
                © 2016

                http://doi.wiley.com/10.1002/tdm_license_1

                http://onlinelibrary.wiley.com/termsAndConditions

                http://onlinelibrary.wiley.com/termsAndConditions

                History

                Comments

                Comment on this article