      Cost-effective rapid prototyping and assembly of poly(methyl methacrylate) microfluidic devices

      research-article
      ,
      Scientific Reports
      Nature Publishing Group UK

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The difficulty in translating conventional microfluidics from laboratory prototypes to commercial products has shifted research efforts towards thermoplastic materials for their higher translational potential and amenability to industrial manufacturing. Here, we present an accessible method to fabricate and assemble polymethyl methacrylate (PMMA) microfluidic devices in a “mask-less” and cost-effective manner that can be applied to manufacture a wide range of designs due to its versatility. Laser micromachining offers high flexibility in channel dimensions and morphology by controlling the laser properties, while our two-step surface treatment based on exposure to acetone vapour and low-temperature annealing enables improvement of the surface quality without deformation of the device. Finally, we demonstrate a capillarity-driven adhesive delivery bonding method that can produce an effective seal between PMMA devices and a variety of substrates, including glass, silicon and LiNbO 3. We illustrate the potential of this technique with two microfluidic devices, an H-filter and a droplet generator. The technique proposed here offers a low entry barrier for the rapid prototyping of thermoplastic microfluidics, enabling iterative design for laboratories without access to conventional microfabrication equipment.

          Related collections

          Most cited references39

          • Record: found
          • Abstract: found
          • Article: not found

          Dynamic pattern formation in a vesicle-generating microfluidic device.

          Spatiotemporal pattern formation occurs in a variety of nonequilibrium physical and chemical systems. Here we show that a microfluidic device designed to produce reverse micelles can generate complex, ordered patterns as it is continuously operated far from thermodynamic equilibrium. Flow in a microfluidic system is usually simple-viscous effects dominate and the low Reynolds number leads to laminar flow. Self-assembly of the vesicles into patterns depends on channel geometry and relative fluid pressures, enabling the production of motifs ranging from monodisperse droplets to helices and ribbons.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Preparation of monodisperse biodegradable polymer microparticles using a microfluidic flow-focusing device for controlled drug delivery.

            Degradable microparticles have broad utility as vehicles for drug delivery and form the basis of several therapies approved by the US Food and Drug Administration. Conventional emulsion-based methods of manufacturing produce particles with a wide range of diameters (and thus kinetics of release) in each batch. This paper describes the fabrication of monodisperse, drug-loaded microparticles from biodegradable polymers using the microfluidic flow-focusing (FF) devices and the drug-delivery properties of those particles. Particles are engineered with defined sizes, ranging from 10 microm to 50 microm. These particles are nearly monodisperse (polydispersity index = 3.9%). A model amphiphilic drug (bupivacaine) is incorporated within the biodegradable matrix of the particles. Kinetic analysis shows that the release of the drug from these monodisperse particles is slower than that from conventional methods of the same average size but a broader distribution of sizes and, most importantly, exhibit a significantly lower initial burst than that observed with conventional particles. The difference in the initial kinetics of drug release is attributed to the uniform distribution of the drug inside the particles generated using the microfluidic methods. These results demonstrate the utility of microfluidic FF for the generation of homogenous systems of particles for the delivery of drugs.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Transition from squeezing to dripping in a microfluidic T-shaped junction

                Bookmark

                Author and article information

                Contributors
                a.del-rio-hernandez@imperial.ac.uk
                Journal
                Sci Rep
                Sci Rep
                Scientific Reports
                Nature Publishing Group UK (London )
                2045-2322
                3 May 2018
                3 May 2018
                2018
                : 8
                : 6971
                Affiliations
                ISNI 0000 0001 2113 8111, GRID grid.7445.2, Cellular and Molecular Biomechanics Laboratory, , Department of Bioengineering, Imperial College London, ; London, SW7 2AZ UK
                Author information
                http://orcid.org/0000-0001-5062-8910
                Article
                25202
                10.1038/s41598-018-25202-4
                5934357
                29725034
                a66bfa04-9dd8-4eb8-a436-42a8f67e0591
                © The Author(s) 2018

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 17 January 2018
                : 17 April 2018
                Categories
                Article
                Custom metadata
                © The Author(s) 2018

                Uncategorized
                Uncategorized

                Comments

                Comment on this article