      British society of gastroenterology Endoscopy Quality Improvement Programme (EQIP): overview and progress

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          High quality gastrointestinal (GI) endoscopy improves patient care. Raising standards in endoscopy improves diagnostic accuracy, management of pathology and ultimately improves outcomes. Historical identification of significant variation in colonoscopy quality led to the development of the Joint Advisory Group (JAG) on GI Endoscopy, the Global Rating Scale (GRS), JAG Endoscopy Training System (JETS) training and certification. These measures led to major improvements in UK endoscopy but significant variation in practice still exists. To improve quality further the British Society of Gastroenterology Endoscopy Quality Improvement (EQIP) has been established with the aim of raising quality and reducing variation in the quality of UK endoscopy. A multifaceted approach to quality improvement (QI) will be undertaken and is described in this manuscript. Upper GI EQIP will support adoption of standards alongside regional upskilling courses. Lower GI EQIP will focus on supporting endoscopists to achieve current standards alongside approaches to reducing postcolonoscopy colorectal cancer rates. Endoscopic retrograde cholangiopancreatography EQIP will adopt a regional approach of using local data to support network-based QI. Newer areas of endoscopy practice such as small bowel endoscopy and endoscopic ultrasound will focus on identifying key performance indicators as well as standardising training and accreditation pathways. EQIP will also support QI in management of GI bleeding as well as standardising the approach to new techniques and technologies. Where evidence is lacking, approaches to gather new evidence and support the translation into clinical practice will be supported.

          Related collections

          Most cited references17

          • Record: found
          • Abstract: found
          • Article: not found

          Quality indicators for colonoscopy and the risk of interval cancer.

          Although rates of detection of adenomatous lesions (tumors or polyps) and cecal intubation are recommended for use as quality indicators for screening colonoscopy, these measurements have not been validated, and their importance remains uncertain. We used a multivariate Cox proportional-hazards regression model to evaluate the influence of quality indicators for colonoscopy on the risk of interval cancer. Data were collected from 186 endoscopists who were involved in a colonoscopy-based colorectal-cancer screening program involving 45,026 subjects. Interval cancer was defined as colorectal adenocarcinoma that was diagnosed between the time of screening colonoscopy and the scheduled time of surveillance colonoscopy. We derived data on quality indicators for colonoscopy from the screening program's database and data on interval cancers from cancer registries. The primary aim of the study was to assess the association between quality indicators for colonoscopy and the risk of interval cancer. A total of 42 interval colorectal cancers were identified during a period of 188,788 person-years. The endoscopist's rate of detection of adenomas was significantly associated with the risk of interval colorectal cancer (P=0.008), whereas the rate of cecal intubation was not significantly associated with this risk (P=0.50). The hazard ratios for adenoma detection rates of less than 11.0%, 11.0 to 14.9%, and 15.0 to 19.9%, as compared with a rate of 20.0% or higher, were 10.94 (95% confidence interval [CI], 1.37 to 87.01), 10.75 (95% CI, 1.36 to 85.06), and 12.50 (95% CI, 1.51 to 103.43), respectively (P=0.02 for all comparisons). The adenoma detection rate is an independent predictor of the risk of interval colorectal cancer after screening colonoscopy. 2010 Massachusetts Medical Society
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Colonoscopic withdrawal times and adenoma detection during screening colonoscopy.

            Colonoscopy is commonly used to screen for neoplasia. To assess the performance of screening colonoscopy in everyday practice, we conducted a study of the rates of detection of adenomas and the amount of time taken to withdraw the colonoscope among endoscopists in a large community-based practice. During a 15-month period, 12 experienced gastroenterologists performed 7882 colonoscopies, of which 2053 were screening examinations in subjects who had not previously undergone colonoscopy. We recorded the numbers, sizes, and histologic features of the neoplastic lesions detected during screening, as well as the duration of insertion and of withdrawal of the colonoscope during the procedure. We compared rates of detection of neoplastic lesions among gastroenterologists who had mean colonoscopic withdrawal times of less than 6 minutes with the rates of those who had mean withdrawal times of 6 minutes or more. According to experts, 6 minutes is the minimum length of time to allow adequate inspection during instrument withdrawal. Neoplastic lesions (mostly adenomatous polyps) were detected in 23.5% of screened subjects. There were large differences among gastroenterologists in the rates of detection of adenomas (range of the mean number of lesions per subject screened, 0.10 to 1.05; range of the percentage of subjects with adenomas, 9.4 to 32.7%) and in their times of withdrawal of the colonoscope from the cecum to the anus (range, 3.1 to 16.8 minutes for procedures during which no polyps were removed). As compared with colonoscopists with mean withdrawal times of less than 6 minutes, those with mean withdrawal times of 6 minutes or more had higher rates of detection of any neoplasia (28.3% vs. 11.8%, P<0.001) and of advanced neoplasia (6.4% vs. 2.6%, P=0.005). In this large community-based gastroenterology practice, we observed greater rates of detection of adenomas among endoscopists who had longer mean times for withdrawal of the colonoscope. The effect of variation in withdrawal times on lesion detection and the prevention of colorectal cancer in the context of widespread colonoscopic screening is not known. Ours was a preliminary study, so the generalizability and implications for clinical practice need to be determined by future studies. 2006 Massachusetts Medical Society
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Papillary cannulation and sphincterotomy techniques at ERCP: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline.

              This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It provides practical advice on how to achieve successful cannulation and sphincterotomy at minimum risk to the patient. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations 1 ESGE suggests that difficult biliary cannulation is defined by the presence of one or more of the following: more than 5 contacts with the papilla whilst attempting to cannulate; more than 5 minutes spent attempting to cannulate following visualization of the papilla; more than one unintended pancreatic duct cannulation or opacification (low quality evidence, weak recommendation). 2 ESGE recommends the guidewire-assisted technique for primary biliary cannulation, since it reduces the risk of post-ERCP pancreatitis (moderate quality evidence, strong recommendation). 3 ESGE recommends using pancreatic guidewire (PGW)-assisted biliary cannulation in patients where biliary cannulation is difficult and repeated unintentional access to the main pancreatic duct occurs (moderate quality evidence, strong recommendation). ESGE recommends attempting prophylactic pancreatic stenting in all patients with PGW-assisted attempts at biliary cannulation (moderate quality evidence, strong recommendation). 4 ESGE recommends needle-knife fistulotomy as the preferred technique for precutting (moderate quality evidence, strong recommendation). ESGE suggests that precutting should be used only by endoscopists who achieve selective biliary cannulation in more than 80 % of cases using standard cannulation techniques (low quality evidence, weak recommendation). When access to the pancreatic duct is easy to obtain, ESGE suggests placement of a pancreatic stent prior to precutting (moderate quality evidence, weak recommendation). 5 ESGE recommends that in patients with a small papilla that is difficult to cannulate, transpancreatic biliary sphincterotomy should be considered if unintentional insertion of a guidewire into the pancreatic duct occurs (moderate quality evidence, strong recommendation).In patients who have had transpancreatic sphincterotomy, ESGE suggests prophylactic pancreatic stenting (moderate quality evidence, strong recommendation). 6 ESGE recommends that mixed current is used for sphincterotomy rather than pure cut current alone, as there is a decreased risk of mild bleeding with the former (moderate quality evidence, strong recommendation). 7 ESGE suggests endoscopic papillary balloon dilation (EPBD) as an alternative to endoscopic sphincterotomy (EST) for extracting CBD stones < 8 mm in patients without anatomical or clinical contraindications, especially in the presence of coagulopathy or altered anatomy (moderate quality evidence, strong recommendation). 8 ESGE does not recommend routine biliary sphincterotomy for patients undergoing pancreatic sphincterotomy, and suggests that it is reserved for patients in whom there is evidence of coexisting bile duct obstruction or biliary sphincter of Oddi dysfunction (moderate quality evidence, weak recommendation). 9 In patients with periampullary diverticulum (PAD) and difficult cannulation, ESGE suggests that pancreatic duct stent placement followed by precut sphincterotomy or needle-knife fistulotomy are suitable options to achieve cannulation (low quality evidence, weak recommendation).ESGE suggests that EST is safe in patients with PAD. In cases where EST is technically difficult to complete as a result of a PAD, large stone removal can be facilitated by a small EST combined with EPBD or use of EPBD alone (low quality evidence, weak recommendation). 10 For cannulation of the minor papilla, ESGE suggests using wire-guided cannulation, with or without contrast, and sphincterotomy with a pull-type sphincterotome or a needle-knife over a plastic stent (low quality evidence, weak recommendation).When cannulation of the minor papilla is difficult, ESGE suggests secretin injection, which can be preceded by methylene blue spray in the duodenum (low quality evidence, weak recommendation). 11 In patients with choledocholithiasis who are scheduled for elective cholecystectomy, ESGE suggests intraoperative ERCP with laparoendoscopic rendezvous (moderate quality evidence, weak recommendation). ESGE suggests that when biliary cannulation is unsuccessful with a standard retrograde approach, anterograde guidewire insertion either by a percutaneous or endoscopic ultrasound (EUS)-guided approach can be used to achieve biliary access (low quality evidence, weak recommendation). 12 ESGE suggests that in patients with Billroth II gastrectomy ERCP should be performed in referral centers, with the side-viewing endoscope as a first option; forward-viewing endoscopes are the second choice in cases of failure (low quality evidence, weak recommendation). A straight standard ERCP catheter or an inverted sphincterotome, with or without the guidewire, is recommended by ESGE for biliopancreatic cannulation in patients who have undergone Billroth II gastrectomy (low quality evidence, strong recommendation). Endoscopic papillary ballon dilation (EPBD) is suggested as an alternative to sphincterotomy for stone extraction in the setting of patients with Billroth II gastrectomy (low quality evidence, weak recommendation).In patients with complex post-surgical anatomy ESGE suggests referral to a center where device-assisted enteroscopy techniques are available (very low quality evidence, weak recommendation).
                Bookmark

                Author and article information

                Journal
                Frontline Gastroenterology
                Frontline Gastroenterol
                BMJ
                2041-4137
                2041-4145
                February 19 2019
                April 2019
                April 2019
                January 18 2019
                : 10
                : 2
                : 148-153
                Article
                10.1136/flgastro-2018-101073
                6540284
                31205655
                bbc0203f-215c-4820-a37f-979a7673b9d6
                © 2019
                History

                Comments

                Comment on this article