31
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Effect of Fatigue Upon Performance and Electromyographic Activity in 6-RM Bench Press

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The aim of this study was to examine the effect of fatigue during one set of 6-RM bench pressing upon the muscle patterning and performance. Fourteen resistance-trained males (age 22.5±2.0 years, stature 1.82±0.07 m, body mass 82.0±7.8 kg) conducted a 6-RM bench press protocol. Barbell kinematics and EMG activity of pectoralis major, deltoid anterior, biceps brachii, triceps brachii, rectus abdominis, oblique external and erector spinae were measured in each repetition during the 6-RM bench press. Total lifting time increased and the velocity in the ascending movement decreased (p≤0.001). However, the kinematics in the descending phase deferred: the time decreased and velocity increased during the 6-RM (p≤0.001). Generally, muscles increased their EMG amplitude during the six repetitions in the ascending movement, while only three of the seven measured muscles showed an increase over the six repetitions in the descending part in 6-RM bench pressing. It was concluded that the bench pressing performance decreased (lower barbell velocities and longer lifting times) with increasing fatigue in the 6-RM execution. Furthermore EMG increased in the prime movers and the trunk stabilizers (abdominal and spine), while the antagonist muscle (biceps) activity was not affected by fatigue during the lifting phase in a single set of 6-RM bench pressing

          Related collections

          Most cited references22

          • Record: found
          • Abstract: found
          • Article: not found

          Development of recommendations for SEMG sensors and sensor placement procedures.

          The knowledge of surface electromyography (SEMG) and the number of applications have increased considerably during the past ten years. However, most methodological developments have taken place locally, resulting in different methodologies among the different groups of users.A specific objective of the European concerted action SENIAM (surface EMG for a non-invasive assessment of muscles) was, besides creating more collaboration among the various European groups, to develop recommendations on sensors, sensor placement, signal processing and modeling. This paper will present the process and the results of the development of the recommendations for the SEMG sensors and sensor placement procedures. Execution of the SENIAM sensor tasks, in the period 1996-1999, has been handled in a number of partly parallel and partly sequential activities. A literature scan was carried out on the use of sensors and sensor placement procedures in European laboratories. In total, 144 peer-reviewed papers were scanned on the applied SEMG sensor properties and sensor placement procedures. This showed a large variability of methodology as well as a rather insufficient description. A special workshop provided an overview on the scientific and clinical knowledge of the effects of sensor properties and sensor placement procedures on the SEMG characteristics. Based on the inventory, the results of the topical workshop and generally accepted state-of-the-art knowledge, a first proposal for sensors and sensor placement procedures was defined. Besides containing a general procedure and recommendations for sensor placement, this was worked out in detail for 27 different muscles. This proposal was evaluated in several European laboratories with respect to technical and practical aspects and also sent to all members of the SENIAM club (>100 members) together with a questionnaire to obtain their comments. Based on this evaluation the final recommendations of SENIAM were made and published (SENIAM 8: European recommendations for surface electromyography, 1999), both as a booklet and as a CD-ROM. In this way a common body of knowledge has been created on SEMG sensors and sensor placement properties as well as practical guidelines for the proper use of SEMG.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Borg ́s perceived exertion and pain scales

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Update--Ethical standards in sport and exercise science research.

                Bookmark

                Author and article information

                Journal
                J Hum Kinet
                J Hum Kinet
                JHK
                Journal of Human Kinetics
                Akademia Wychowania Fizycznego w Katowicach
                1640-5544
                1899-7562
                27 March 2014
                9 April 2014
                : 40
                : 57-65
                Affiliations
                [1 ]Department of Teacher Education of Nord Trøndelag University College, Levanger Norway.
                [2 ]Department of Teacher Education and Sports of Sogn and Fjordane University College, Sogndal, Norway.
                Author notes
                Corresponding Author: Roland van den Tillaar PhD., Department of Teacher Education, Nord Trøndelag University College, Odins veg 23, 7603 Levanger, Norway, Phone: +47-5767 1883, Fax: 0047-7411 2001, E-mail: roland.tillaar@ 123456hint.no

                Authors submitted their contribution of the article to the editorial board.

                Article
                jhk-40-57
                10.2478/hukin-2014-0007
                4096084
                25031673
                c58ddcca-966d-4024-8644-7823e298d837
                © Editorial Committee of Journal of Human Kinetics

                This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license ( http://creativecommons.org/licenses/by/3.0/).

                History
                : March 2014
                Categories
                Research Article
                Section I – Kinesiology

                emg,resistance exercise,trunk,coordination,kinematics
                emg, resistance exercise, trunk, coordination, kinematics

                Comments

                Comment on this article