      Evaluation of X-ray fluorescence spectroscopy as a method for the rapid and direct determination of sodium in cheese.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Cheese manufacturers indirectly determine Na in cheese by analysis of Cl using the Volhard method, assuming that all Cl came from NaCl. This method overestimates the actual Na content in cheeses when Na replacers (e.g., KCl) are used. A direct and rapid method for Na detection is needed. X-ray fluorescence spectroscopy (XRF), a mineral analysis technique used in the mining industry, was investigated as an alternative method of Na detection in cheese. An XRF method for the detection of Na in cheese was developed and compared with inductively coupled plasma optical emission spectroscopy (ICP-OES; the reference method for Na in cheese) and Cl analyzer. Sodium quantification was performed by multi-point calibration with cheese standards spiked with NaCl ranging from 0 to 4% Na (wt/wt). The Na concentration of each of the cheese standards (discs: 30mm×7mm) was quantified by the 3 methods. A single laboratory method validation was performed; linearity, precision, limit of detection, and limit of quantification were determined. An additional calibration graph was created using cheese standards made from natural or process cheeses manufactured with different ratios of Na:K. Both Na and K calibration curves were linear for the cheese standards. Sodium was quantified in a variety of commercial cheese samples. The Na data obtained by XRF were in agreement with those from ICP-OES and Cl analyzer for most commercial natural cheeses. The XRF method did not accurately determine Na concentration for several process cheese samples, compared with ICP-OES, likely due to the use of unknown types of Na-based emulsifying salts (ES). When a calibration curve was created for process cheese with the specific types of ES used for this cheese, Na content was successfully predicted in the samples. For natural cheeses, the limit of detection and limit of quantification for Na that can be determined with an acceptable level of repeatability, precision, and trueness was 82 and 246mg/100g of cheese, respectively. Calibration graphs should be created with standards that reflect the concentration range, ratio, and salt type present in the cheeses. This XRF method can be successfully used for the rapid and direct measurement of Na content in a wide variety of natural cheeses. Commercial process cheese manufacturers use proprietary blends of ES. We did find that the XRF technique worked for process cheese when the calibration graphs were created with the specific types of ES actually used.

          Related collections

          Author and article information

          Journal
          J Dairy Sci
          Journal of dairy science
          American Dairy Science Association
          1525-3198
          0022-0302
          Aug 2015
          : 98
          : 8
          Affiliations
          [1 ] Wisconsin Center for Dairy Research, University of Wisconsin, Madison 53706.
          [2 ] Wisconsin Center for Dairy Research, University of Wisconsin, Madison 53706. Electronic address: rani@cdr.wisc.edu.
          Article
          S0022-0302(15)00372-0
          10.3168/jds.2014-9055
          26051319
          c5f47cfa-f121-4b36-a742-b8063f922275
          Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
          History

          X-ray fluorescence spectroscopy,cheese,sodium
          X-ray fluorescence spectroscopy, cheese, sodium

          Comments

          Comment on this article