8
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Reservoir and conduit function of right atrium: impact on right ventricular filling and cardiac output.

      American Journal of Physiology - Heart and Circulatory Physiology
      Acute Disease, Animals, Atrial Function, Right, physiology, Cardiac Catheterization, Cardiac Output, Hypertension, Pulmonary, physiopathology, Pulmonary Artery, Regression Analysis, Sheep, Tourniquets, Ventricular Function, Right, Ventricular Pressure

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The purpose of this study was to investigate the relationship between right atrial (RA) reservoir and conduit function and to determine how hemodynamic changes influence this relationship and its impact on cardiac output. In 11 open-chest sheep, RA reservoir and conduit function were quantified as RA inflow with the tricuspid valve closed versus open, respectively. Conduit function was separated into early (before A wave) and late (after A wave) components. The effects of inotropic stimulation, partial pulmonary artery occlusion, and pericardiotomy were tested. At baseline with the pericardium intact, reservoir function accounted for 0.56 (SD 0.13) of RA inflow, early conduit for 0.29 (SD 0.07), and late conduit (during RA contraction) for 0.16 (SD 0.11). Inotropic stimulation decreased conduit function and increased reservoir function, but these effects did not reach statistical significance. With partial pulmonary artery occlusion, early conduit function fell to 0.20 (SD 0.11) (P < 0.04), and the conduit-to-reservoir ratio decreased by 41% (P < 0.03). Similarly, after pericardiotomy, early conduit function fell to 0.14 (SD 0.09) (P < 0.004), reservoir function increased to 0.72 (SD 0.08) (P < 0.04), and, consequently, the early conduit-to-reservoir ratio decreased by 63% (P < 0.006). Cardiac output was inversely related to the conduit-to-reservoir ratio (r = 0.39, P < 0.001). This study demonstrated that the right atrium adjusts its ability to act more as a reservoir than a conduit in a dynamic manner. The RA conduit-to-reservoir ratio was directly related to the right ventricular pressure-RA pressure gradient at the time of maximum RA volume, with increased ventricular pressures favoring conduit function, but it was inversely related to cardiac output, with an increase in the reservoir contribution favoring improved cardiac output.

          Related collections

          Author and article information

          Comments

          Comment on this article