19
views
0
recommends
+1 Recommend
1 collections
    0
    shares

      Authors - did you know SICOT-J has been awarded the DOAJ Seal for "best practice in open access publishing"?

      • Indexed in Scopus
      • 30% discount on article processing charges (APCs) for members of SICOT

      Instructions for authors, online submissions and free e-mail alerts all available here 

      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Lengthening over nails using the double plate system ONAS-DPS

      case-report
      1 , *
      SICOT-J
      EDP Sciences
      Lengthening over nail, External fixation, Intramedullary nail, Angle stability plate

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Stable insertion of large Schanz screws behind an intramedullary (IM) nail when lengthening over nails (LON) may be difficult due to the limited bone stock. Additionally, the highly probable contact between the screws and IM nail (which is difficult to avoid) increases the likelihood of infection spreading from the skin via Schanz screws directly to the IM nail. A new device for LON has been developed. Instead of inserting Schanz screws from the external fixator beside the IM nail (as in standard LON), a system of two overlaying plates was constructed. Schanz screws can be fixed to the plates without entering the bone. The plates are fixed to the bone using four angle stability screws. The holes in the plates offer stabile fixation for a chosen angle under which the screw is positioned through the cortical bone. Using the new system there is no need to place Schanz screws behind the IM nail. Instead, Schanz screws pass to the plate and not through the bone. The new system for elongation over IM nail is called “Over Nail Angle Stability-Double Plate System” (ONAS-DPS) [Antolič V (2013) Modular side device with an intramedullary nail for guiding a bone during its lengthening. World Intellectual Property Organization. International Publication number: WO 2013/176632 A1].

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          Femoral lengthening over an intramedullary nail. A matched-case comparison with Ilizarov femoral lengthening.

          Twenty-nine patients (thirty-two femora) had femoral lengthening over an intramedullary nail, with the nail and the external fixator applied concomitantly at the time of the femoral osteotomy. After gradual distraction at a rate of one millimeter per day, the nail was locked and the fixator was removed. The mean age was twenty-six years (range, ten to fifty-three years), and the mean amount of lengthening was 5.8 centimeters (range, two to thirteen centimeters). For comparison, thirty-one patients (thirty-two limbs) who had had standard Ilizarov femoral lengthening were matched with the group that had had lengthening over an intramedullary nail; the matching was performed on the basis of the amount of lengthening, the age of the patient, the etiology of the indication for lengthening, and the level of difficulty of the procedure. Lengthening over an intramedullary nail reduced the average duration of external fixation by almost one-half. The radiographic consolidation index (the number of months needed for radiographic consolidation for each centimeter of lengthening) for the limbs that had had lengthening over an intramedullary nail was reduced significantly (p < 0.001) compared with that for the matched-case group. The range of motion of the knee returned to normal a mean of 2.2 times faster in the group that had had lengthening over an intramedullary nail. There were six refractures of the distraction bone in the matched-case group. In the group that had had lengthening over an intramedullary nail, one nail and one proximal locking screw failed. The over-all rate of complications was 1.4 per cent in the group that had had lengthening over an intramedullary nail compared with 1.9 per cent in the matched-case group. With the numbers of patients available for study, we could not detect a significant difference between the groups with respect to the operative time (p = 0.124); however, the cost of treatment and the estimated blood loss were higher in the group that had had lengthening over an intramedullary nail. On the basis of clinical and radiographic criteria, there were twenty-three excellent, seven good, and two fair results in the group that had had lengthening over an intramedullary nail compared with twenty-six excellent, four good, and two fair results in the matched-case group (p = 0.37). The advantages of lengthening over an intramedullary nail include a decrease in the duration of external fixation, protection against refracture, and earlier rehabilitation.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Precision of the PRECICE internal bone lengthening nail.

            Previous designs of internal bone lengthening devices have been fraught with imprecise distraction, resulting in nerve injuries, joint contractures, nonunions, and other complications. Recently, a magnet-operated PRECICE nail (Ellipse Technologies, Inc, Irvine, CA, USA) was approved by the FDA; however, its clinical efficacy is unknown.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Femoral lengthening with lengthening over a nail has fewer complications than intramedullary skeletal kinetic distraction.

              Lengthening over a nail and internal lengthening nails have been developed to minimize or eliminate patients' time wearing a frame during femur lengthening. However it is unclear whether either of these two approaches results in faster times to union or fewer complications over the other.
                Bookmark

                Author and article information

                Journal
                SICOT J
                SICOT J
                sicotj
                SICOT-J
                EDP Sciences
                2426-8887
                2016
                02 February 2016
                : 2
                : ( publisher-idID: sicotj/2016/01 )
                : 5
                Affiliations
                [1 ] Department of Orthopaedic Surgery, University Medical Centre and Faculty of Medicine Ljubljana Slovenia
                Author notes
                Article
                sicotj150117 10.1051/sicotj/2015040
                10.1051/sicotj/2015040
                4849230
                27163094
                cb6e6168-c987-4011-8986-dd17298fa64d
                © The Authors, published by EDP Sciences, 2016

                This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 14 July 2015
                : 07 December 2015
                Page count
                Figures: 6, Tables: 1, Equations: 0, References: 19, Pages: 5
                Categories
                Lower Limb
                Surgical Technique

                lengthening over nail,external fixation,intramedullary nail,angle stability plate

                Comments

                Comment on this article