2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Urinary elimination kinetics of 3-hydroxybenzo(a)pyrene and 1-hydroxypyrene of workers in a prebake aluminum electrode production plant: Evaluation of diuresis correction methods for routine biological monitoring

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous carcinogenic pollutants emitted in complex mixtures in the ambient air and contribute to the incidence of human cancers. Taking into account all absorption routes, biomonitoring is more relevant than atmospheric measurements to health risk assessment, but knowledge about how to use biomarkers is essential. In this work, urinary elimination kinetic of 1-hydroxypyrene (1-OHP) and 3-hydroxybenzo(a)pyrene (3-OHBaP) were studied in six electrometallurgy workers after PAHs exposure. Spot samples were collected on pre- and post-shift of the last workday then the whole urinations were separately sampled during the weekend. Non-linear mixed effects models were built to study inter- and intra-individual variability of both urinary metabolites toxicokinetic and investigate diuresis correction ways. Comparison of models confirmed the diuresis correction requirement to perform urinary biomonitoring of pyrene and BaP exposure. Urinary creatinine was found as a better way than specific gravity to normalize urinary concentrations of 1-OHP and as a good compromise for 3-OHBaP. Maximum observed levels were 1.0 µmol/mol creatinine and 0.8nmol/mol creatinine for 1-OHP and 3-OHBaP, respectively. Urinary 1-OHP concentrations on post-shift were higher than pre-shift for each subject, while 3-OHBaP levels were steady or decreased, and maximum urinary excretion rates of 3-OHBaP was delayed compared to 1-OHP. These results were consistent with the sampling time previously proposed for 3-OHBaP analysis, the next morning after exposure. Apparent urinary half-life of 1-OHP and 3-OHBaP ranged from 12.0h to 18.2h and from 4.8h to 49.5h, respectively. Finally, inter-individual variability of 1-OHP half-life seemed linked with the cutaneous absorption extent during exposure, while calculation of 3-OHBaP half-life required the awareness of individual urinary background level. The toxicokinetic modeling described here is an efficient tool which could be used to describe elimination kinetic and determine diuresis correction way for any other urinary biomarkers of chemicals or metals exposure.

          Related collections

          Author and article information

          Journal
          Environmental Research
          Environmental Research
          Elsevier BV
          00139351
          May 2016
          May 2016
          : 147
          : 469-479
          Article
          10.1016/j.envres.2016.02.035
          26970901
          cbc4b4a2-06c9-43b6-9fd0-0166240bb0e6
          © 2016

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article