          Abstract

          This article presents the implementation of several variance reduction techniques that dramatically improve the simulation efficiency of ion chamber dose and perturbation factor calculations. The cavity user code for the EGSnrc Monte Carlo code system is extended by photon cross-section enhancement (XCSE), an intermediate phase-space storage (IPSS) technique, and a correlated sampling (CS) scheme. XCSE increases the density of photon interaction sites inside and in the vicinity of the chamber and results-in combination with a Russian Roulette game for electrons that cannot reach the cavity volume-in an increased efficiency of up to a factor of 350 for calculating dose in a Farmer type chamber placed at 10 cm depth in a water phantom. In combination with the IPSS and CS techniques, the efficiency for the calculation of the central electrode perturbation factor Pcel can be increased by up to three orders of magnitude for a single chamber location and by nearly four orders of magnitude when considering the Pcel variation with depth or with distance from the central axis in a large field photon beam. The intermediate storage of the phase-space properties of particles entering a volume that contains many possible chamber locations leads to efficiency improvements by a factor larger than 500 when computing a profile of chamber doses in the field of a linear accelerator photon beam. All techniques are combined in a new EGSnrc user code egs_chamber. Optimum settings for the variance reduction parameters are investigated and are reported for a Farmer type ion chamber. A few example calculations illustrating the capabilities of the egs_chamber code are presented.

          Related collections

          Author and article information

          Journal
          Med Phys
          Medical physics
          Wiley-Blackwell
          0094-2405
          0094-2405
          Apr 2008
          : 35
          : 4
          Affiliations
          [1 ] Institut für Medizinische Physik und Strahlenschutz-IMPS, University of Applied Sciences Giessen-Friedberg, Giessen, Germany. joerg.wulff@tg.fh-giessen.de
          Article
          10.1118/1.2874554
          18491527
          d01317f3-b642-414f-ad50-a3b3e12fec31
          History

          Comments

          Comment on this article