Inviting an author to review:
Find an author and click ‘Invite to review selected article’ near their name.
Search for authorsSearch for similar articles
8
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Augmented reality-based navigation increases precision of pedicle screw insertion

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Precise insertion of pedicle screws is important to avoid injury to closely adjacent neurovascular structures. The standard method for the insertion of pedicle screws is based on anatomical landmarks (free-hand technique). Head-mounted augmented reality (AR) devices can be used to guide instrumentation and implant placement in spinal surgery. This study evaluates the feasibility and precision of AR technology to improve precision of pedicle screw insertion compared to the current standard technique.

          Methods

          Two board-certified orthopedic surgeons specialized in spine surgery and two novice surgeons were each instructed to drill pilot holes for 40 pedicle screws in eighty lumbar vertebra sawbones models in an agar-based gel. One hundred and sixty pedicles were randomized into two groups: the standard free-hand technique (FH) and augmented reality technique (AR). A 3D model of the vertebral body was superimposed over the AR headset. Half of the pedicles were drilled using the FH method, and the other half using the AR method.

          Results

          The average minimal distance of the drill axis to the pedicle wall (MAPW) was similar in both groups for expert surgeons (FH 4.8 ± 1.0 mm vs. AR 5.0 ± 1.4 mm, p = 0.389) but for novice surgeons (FH 3.4 mm ± 1.8 mm, AR 4.2 ± 1.8 mm, p = 0.044).

          Expert surgeons showed 0 primary drill pedicle perforations (PDPP) in both the FH and AR groups. Novices showed 3 (7.5%) PDPP in the FH group and one perforation (2.5%) in the AR group, respectively ( p > 0.005).

          Experts showed no statistically significant difference in average secondary screw pedicle perforations (SSPP) between the AR and the FH set 6-, 7-, and 8-mm screws ( p > 0.05). Novices showed significant differences of SSPP between most groups: 6-mm screws, 18 (45%) vs. 7 (17.5%), p = 0.006; 7-mm screws, 20 (50%) vs. 10 (25%), p = 0.013; and 8-mm screws, 22 (55%) vs. 15 (37.5%), p = 0.053, in the FH and AR group, respectively. In novices, the average optimal medio-lateral convergent angle (oMLCA) was 3.23° (STD 4.90) and 0.62° (STD 4.56) for the FH and AR set screws ( p = 0.017), respectively. Novices drilled with a higher precision with respect to the cranio-caudal inclination angle (CCIA) category ( p = 0.04) with AR.

          Conclusion

          In this study, the additional anatomical information provided by the AR headset superimposed to real-world anatomy improved the precision of drilling pilot holes for pedicle screws in a laboratory setting and decreases the effect of surgeon’s experience. Further technical development and validations studies are currently being performed to investigate potential clinical benefits of the herein described AR-based navigation approach.

          Related collections

          Most cited references24

          • Record: found
          • Abstract: found
          • Article: not found

          Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques.

          With the advances and improvement of computer-assisted surgery devices, computer-guided pedicle screws insertion has been applied to the lumbar, thoracic and cervical spine. The purpose of the present study was to perform a systematic review of all available prospective evidence regarding pedicle screw insertion techniques in the thoracic and lumbar human spine. We considered all prospective in vivo clinical studies in the English literature that assessed the results of different pedicle screw placement techniques (free-hand technique, fluoroscopy guided, computed tomography (CT)-based navigation, fluoro-based navigation). MEDLINE, OVID, and Springer databases were used for the literature search covering the period from January 1950 until May 2010. 26 prospective clinical studies were eventually included in the analysis. These studies included in total 1,105 patients in which 6,617 screws were inserted. In the studies using free-hand technique, the percentage of the screws fully contained in the pedicle ranged from 69 to 94%, with the aid of fluoroscopy from 28 to 85%, using CT navigation from 89 to 100% and using fluoroscopy-based navigation from 81 to 92%. The screws positioned with free-hand technique tended to perforate the cortex medially, whereas the screws placed with CT navigation guidance seemed to perforate more often laterally. In conclusion, navigation does indeed exhibit higher accuracy and increased safety in pedicle screw placement than free-hand technique and use of fluoroscopy.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Pedicle screw placement accuracy: a meta-analysis.

            A meta-analysis of the published literature was conducted specifically looking at accuracy and the postoperative methods used for the assessment of pedicle screw placement in the human spine. This study specifically aimed to identify postoperative methods used for pedicle screw placement assessment, including the most common method, and to report cumulative pedicle screw placement study statistics from synthesis of the published literature. Safety concerns have driven specific interests in the accuracy and precision of pedicle screw placement. A large variation in reported accuracy may exist partly due to the lack of a standardized evaluation method and/or the lack of consensus to what, or in which range, is pedicle screw placement accuracy considered satisfactory. A MEDLINE search was executed covering the span from 1966 until 2006, and references from identified papers were reviewed. An extensive database was constructed for synthesis of the identified studies. Subgroups and descriptive statistics were determined based on the type of population, in vivo or cadaveric, and separated based on whether the assistance of navigation was employed. In total, we report on 130 studies resulting in 37,337 total pedicle screws implanted, of which 34,107 (91.3%) were identified as accurately placed for the combined in vivo and cadaveric populations. The most common assessment method identified pedicle screw violations simply as either present or absent. Overall, the median placement accuracy for the in vivo assisted navigation subgroup (95.2%) was higher than that of the subgroup without the use of navigation (90.3%). Navigation does indeed provide a higher accuracy in the placement of pedicle screws for most of the subgroups presented. However, an exception is found at the thoracic levels for both the in vivo and cadaveric populations, where no advantage in the use of navigation was found.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Recent Development of Augmented Reality in Surgery: A Review

              Introduction The development augmented reality devices allow physicians to incorporate data visualization into diagnostic and treatment procedures to improve work efficiency, safety, and cost and to enhance surgical training. However, the awareness of possibilities of augmented reality is generally low. This review evaluates whether augmented reality can presently improve the results of surgical procedures. Methods We performed a review of available literature dating from 2010 to November 2016 by searching PubMed and Scopus using the terms “augmented reality” and “surgery.” Results. The initial search yielded 808 studies. After removing duplicates and including only journal articles, a total of 417 studies were identified. By reading of abstracts, 91 relevant studies were chosen to be included. 11 references were gathered by cross-referencing. A total of 102 studies were included in this review. Conclusions The present literature suggest an increasing interest of surgeons regarding employing augmented reality into surgery leading to improved safety and efficacy of surgical procedures. Many studies showed that the performance of newly devised augmented reality systems is comparable to traditional techniques. However, several problems need to be addressed before augmented reality is implemented into the routine practice.
                Bookmark

                Author and article information

                Contributors
                cyrill.dennler@gmail.com
                Journal
                J Orthop Surg Res
                J Orthop Surg Res
                Journal of Orthopaedic Surgery and Research
                BioMed Central (London )
                1749-799X
                14 May 2020
                14 May 2020
                2020
                : 15
                : 174
                Affiliations
                [1 ]GRID grid.7400.3, ISNI 0000 0004 1937 0650, Spine Division, University Hospital Balgrist, , University of Zürich, ; Forchstrasse 340, 8008 Zurich, Switzerland
                [2 ]GRID grid.7400.3, ISNI 0000 0004 1937 0650, Department of Radiology, University Hospital Balgrist, , University of Zürich, ; Zurich, Switzerland
                [3 ]GRID grid.7400.3, ISNI 0000 0004 1937 0650, Laboratory for Biomechanics, University Hospital Balgrist, , University of Zürich, ; Zurich, Switzerland
                [4 ]GRID grid.7400.3, ISNI 0000 0004 1937 0650, Computer Assisted Research and Development Group, University Hospital Balgrist, , University of Zürich, ; Zurich, Switzerland
                Author information
                http://orcid.org/0000-0001-5063-5897
                Article
                1690
                10.1186/s13018-020-01690-x
                7227090
                32410636
                d04856ac-7ad9-4368-afa3-161ed9e24aff
                © The Author(s) 2020

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

                History
                : 1 October 2019
                : 29 April 2020
                Categories
                Research Article
                Custom metadata
                © The Author(s) 2020

                Surgery
                Surgery

                Comments

                Comment on this article