      Optimization of MLC parameters for TPS calculation and dosimetric verification: application to single isocenter radiosurgery of multiple brain lesions using VMAT.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Linac and MLC-based stereotactic radiosurgery (SRS) using single-isocenter-multiple-target (SIMT) VMAT has become increasingly popular in the management of multi-focal cranial metastases. However, significant geometrical and dosimetric challenges exist due to the typically small target volumes and in most cases, non-isocentric locations. To the best of our knowledge, there hasn't been a study in the optimization of MLC parameters, in the context of SIMT SRS, to ensure TPS calculation accuracy. In this work, we set out to optimize the dosimetric leaf gap (DLG) for the HD MLC installed on dedicated stereotactic Varian STx systems using a diverse group of 21 clinical SRS and SBRT plans. These plans featured a broad range of target sizes and target-to-isocenter distances that are typical of the stereotactic cases treated on these systems. Dose discrepancies between TPS calculations and verification measurements using a previously validated diode array Delta4 (ScandiDos) were minimized in a balanced manner to accommodate the variety of stereotactic plans. A DLG of 0.6 mm was found to be 'optimal' for the HD MLC and for the 'typical' plans treated on our STx systems. The finding was independently verified using commercially available 3D polymer gel dosimeter CrystalBallTM (MGS Research Inc.). 3D verification for 6 SIMT SRS plans, consisted of 5 to 15 targets, achieved an average gamma score of 97.3% (σ = 2.0%) on 3%/2 mm criteria with a cutoff isodose level of 20%. We further examined the practice of routine dosimetric verifications including the selection of appropriate detectors and optimal gamma parameters. We found that the commonly used standard 3%/3 mm criteria would have resulted in all but 4 (out of 2840) clinical plans achieving a gamma score of 95% or better, and therefore, losing sensitivity to detect potential dosimetric discrepancies. Based on the characteristics of stereotactic plans, a more stringent distance-to-agreement parameter is needed.

          Related collections

          Author and article information

          Journal
          Biomed Phys Eng Express
          Biomedical physics & engineering express
          IOP Publishing
          2057-1976
          2057-1976
          November 25 2019
          : 6
          : 1
          Affiliations
          [1 ] Department of Radiation Oncology, Brigham and Women's Hospital and Dana Farber Cancer Institute, Harvard Medical School, Boston, MA, United States of America.
          Article
          10.1088/2057-1976/ab57ce
          33438592
          d272801f-2807-4521-9304-f56dded57ae8
          History

          Comments

          Comment on this article