      Detector comparison for small field output factor measurements in flattening filter free photon beams.

      Radiotherapy and Oncology
      Alanine, chemistry, Calibration, Filtration, instrumentation, Particle Accelerators, Phantoms, Imaging, Photons, Radiometry, Uncertainty

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The applicability of various detectors for small field dosimetry and whether there are differences in the detector response when irradiated with FF- and FFF-beams was investigated. Output factors of 6 and 10 MV FF- and FFF-beams were measured with 14 different online detectors using field sizes between 10 × 10 and 0.6 × 0.6 cm(2) at a depth of 5 cm of water in isocentric conditions. Alanine pellets with a diameter of 5 and 2.5mm were used as reference dosimeters for field sizes down to 1.2 × 1.2 and 0.6 × 0.6 cm(2), respectively. The ratio of the relative output measured with the online detectors to the relative output measured with alanine was evaluated (referred to as dose response ratio). The dose response ratios of two different shielded diodes measured with 10 MV FF-beams deviated substantially by 2-3% compared to FFF-beams at a field size of 0.6 × 0.6 cm(2). This difference was less pronounced for 6 MV FF- and FFF-beams. For all other detectors the dose response ratios of FF- and FFF-beams showed no significant difference. The dose response ratios of the majority of the detectors agreed within the measurement uncertainty when irradiated with FF- and FFF-beams. Of all investigated detectors, the microDiamond and the unshielded diodes would require only small corrections which make them suitable candidates for small field dosimetry in FF- and FFF-beams. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

          Related collections

          Author and article information

          Journal
          24257020
          10.1016/j.radonc.2013.10.022

          Chemistry
          Alanine,chemistry,Calibration,Filtration,instrumentation,Particle Accelerators,Phantoms, Imaging,Photons,Radiometry,Uncertainty

          Comments

          Comment on this article