10
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Reverse shoulder arthroplasty. Part 1: Systematic review of clinical and functional outcomes

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Many factors influence the outcomes of reverse shoulder arthroplasty (RSA). The purpose of this study was to compare the clinical and functional outcomes of RSA depending on the surgical approach, type of prosthesis, and indication for surgery through a comprehensive, systematic review.

          A literature search was conducted (1985 to June 2012) using PubMed, CINAHL, EBSCO–SPORTDiscus, and Cochrane Central Register of Controlled Trials. Levels I–IV evidence, in-vivo human studies (written in English with minimum of 2 years of follow-up and sample size of 10 patients) reporting clinical and/or functional outcomes after RSA were included. The outcomes were analyzed depending on the surgical approach, type of prosthesis (with medialized or lateralized center of rotation), or indication for surgery.

          A total of 35 studies were included involving 2049 patients (mean [SD] percentage of females, age, and follow-up of 71.6% [13.4], 71.5 years [3.7], and 43.1 months [18.8], respectively). Studies using deltopectoral approach with lateralized prostheses demonstrated greater improvement in external rotation compared with medialized prostheses with the same approach (mean 22.9° and 5°, respectively). In general, RSA for cuff tear arthropathy demonstrated higher improvements in Constant and American Shoulder and Elbow Society scores, and range of motion compared with revision of anatomic prosthesis, failed rotator cuff repair, and fracture sequelae.

          Lateralized prostheses provided more improvement in external rotation compared to medialized prostheses. Indications of RSA for cuff tear arthropathy demonstrated higher improvements in the outcomes compared with other indications. RSA demonstrated high patient's satisfaction regardless of the type of prosthesis or indication for surgery.

          Level of Evidence:

          Level IV.

          Related collections

          Most cited references49

          • Record: found
          • Abstract: found
          • Article: not found

          Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders.

          We reviewed 80 shoulders (77 patients) at a mean follow-up of 44 months after insertion of a Grammont inverted shoulder prosthesis. Three implants had failed and had been revised. The mean Constant score had increased from 22.6 points pre-operatively to 65.6 points at review. In 96% of these shoulders there was no or only minimal pain. The mean active forward elevation increased from 73 degrees to 138 degrees. The integrity of teres minor is essential for the recovery of external rotation and significantly influenced the Constant score. Five cases of aseptic loosening of the glenoid and seven of dissociation of the glenoid component were noted. This study confirms the promising early results obtained with the inverted prosthesis in the treatment of a cuff-tear arthropathy. It should be considered in the treatment of osteoarthritis with a massive tear of the cuff but should be reserved for elderly patients.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Grammont reverse prosthesis: design, rationale, and biomechanics.

            Combined destruction of the rotator cuff and the glenohumeral joint may lead to a painful and pseudo-paralyzed shoulder. In this situation a nonconstrained shoulder prosthesis yields a limited functional result or may even be contraindicated. Previous constrained prostheses (ball-and-socket or reverse ball-and-socket designs) have failed because their center of rotation remained lateral to the scapula, which limited motion and produced excessive torque on the glenoid component, leading to early loosening. The reverse prosthesis designed by Paul Grammont, unlike any previous reverse ball-and-socket design, has introduced 2 major innovations that have led to its success: (1) a large glenoid hemisphere with no neck and (2) a small humeral cup almost horizontally oriented with a nonanatomic inclination of 155 degrees, covering less than half of the glenosphere. This design medializes and stabilizes the center of rotation, minimizes torque on the glenoid component, and helps in recruiting more fibers of the anterior and posterior deltoid to act as abductors. Furthermore, the humerus is lowered relative to the acromion, restoring and even increasing deltoid tension. The Grammont reverse prosthesis imposes a new biomechanical environment for the deltoid muscle to act, thus allowing it to compensate for the deficient rotator cuff muscles. The clinical experience does live up to the biomechanical concept: the reverse prosthesis restores active elevation above 90 degrees in patients with a cuff-deficient shoulder. However, external rotation often remains limited, particularly in patients with an absent or fat-infiltrated teres minor. Internal rotation is also rarely restored after a reverse prosthesis. Failure to restore sufficient tension in the deltoid may result in prosthetic instability. The design does appear to protect against early loosening of the glenoid component, but impingement of the humeral cup on the scapular neck can lead to scapular notching and polyethylene wear. This is a cause for concern, especially as the notch is often more extensive than can be explained by impingement alone. Bony lysis of the scapula may also be related to a polyethylene granuloma. Further follow-up is required to ensure that loosening does not become a problem in the long term, and it has been recommended to limit its use to elderly patients, arguably those aged over 70 years. Despite these concerns, the reverse prosthesis, based on the biomechanical Grammont concept, offers a true surgical option in several situations where only limited possibilities were previously available: cuff tear arthrosis, persistent shoulder pseudo-paralysis due to a massive and irreparable cuff tear, severe fracture sequelae, prosthetic revision in a cuff-deficient shoulder, and tumor surgery. Finally, surgeons must be aware that results are less predictable and complication/revision rates are higher in revision surgery.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Problems, complications, reoperations, and revisions in reverse total shoulder arthroplasty: a systematic review.

                Bookmark

                Author and article information

                Journal
                Int J Shoulder Surg
                Int J Shoulder Surg
                IJSS
                International Journal of Shoulder Surgery
                Medknow Publications & Media Pvt Ltd (India )
                0973-6042
                Jan-Mar 2015
                : 9
                : 1
                : 24-31
                Affiliations
                [1]Orthopaedics and Sports Medicine Institute, Department of Orthopaedics & Rehabilitation, University of Florida, Gainesville, Florida, USA
                [1 ]Department of Orthopaedic Surgery and Traumatology, Parc de Salut Mar - Hospital del Mar & Hospital de l'Esperança, Universitat Autonoma de Barcelona (UAB), Barcelona, Spain
                Author notes
                Address for correspondence: Dr. Thomas W. Wright, Orthopaedics and Sports Medicine Institute, University of Florida, 3450 Hull Road, Gainesville, Florida, 32611, USA. E-mail: wrightw@ 123456ortho.ufl.edu
                Article
                IJSS-9-24
                10.4103/0973-6042.150226
                4325387
                25709242
                e5645e31-585a-4291-b5db-fc3c3d932dec
                Copyright: © International Journal of Shoulder Surgery

                This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                Categories
                Review Article

                Surgery
                outcomes,reverse shoulder arthroplasty,systematic review
                Surgery
                outcomes, reverse shoulder arthroplasty, systematic review