      Assessment of Intra-Abdominal Pressure with a Novel Continuous Bladder Pressure Monitor—A Clinical Validation Study

      , , , , , , ,
      Life
      MDPI AG

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction: Intra-abdominal hypertension and the resulting abdominal compartment syndrome are serious complications of severely ill patients. Diagnosis requires an intra-abdominal pressure (IAP) measurement, which is currently cumbersome and underused. We aimed to test the accuracy of a novel continuous IAP monitor. Methods: Adults having laparoscopic surgery and requiring urinary catheter intra-operatively were recruited to this single-arm validation study. IAP measurements using the novel monitor and a gold-standard foley manometer were compared. After anesthesia induction, a pneumoperitoneum was induced through a laparoscopic insufflator, and five randomly pre-defined pressures (between 5 and 25 mmHg) were achieved and simultaneously measured via both methods in each participant. Measurements were compared using Bland–Altman analysis. Results: In total, 29 participants completed the study and provided 144 distinct pairs of pressure measurements that were analyzed. A positive correlation between the two methods was found (R2 = 0.93). There was good agreement between the methods, with a mean bias (95% CI) of −0.4 (−0.6, −0.1) mmHg and a standard deviation of 1.3 mmHg, which was statistically significant but of no clinical importance. The limits of agreement (where 95% of the differences are expected to fall) were −2.9 and 2.2 mmHg. The proportional error was statistically insignificant (p = 0.85), suggesting a constant agreement between the methods across the range of values tested. The percentage error was 10.7%. Conclusions: Continuous IAP measurements using the novel monitor performed well in the clinical setup of controlled intra-abdominal hypertension across the evaluated range of pressures. Further studies should expand the range to more pathological values.

          Related collections

          Most cited references16

          • Record: found
          • Abstract: found
          • Article: not found

          Intra-abdominal hypertension and the abdominal compartment syndrome: updated consensus definitions and clinical practice guidelines from the World Society of the Abdominal Compartment Syndrome

          Purpose To update the World Society of the Abdominal Compartment Syndrome (WSACS) consensus definitions and management statements relating to intra-abdominal hypertension (IAH) and the abdominal compartment syndrome (ACS). Methods We conducted systematic or structured reviews to identify relevant studies relating to IAH or ACS. Updated consensus definitions and management statements were then derived using a modified Delphi method and the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) guidelines, respectively. Quality of evidence was graded from high (A) to very low (D) and management statements from strong RECOMMENDATIONS (desirable effects clearly outweigh potential undesirable ones) to weaker SUGGESTIONS (potential risks and benefits of the intervention are less clear). Results In addition to reviewing the consensus definitions proposed in 2006, the WSACS defined the open abdomen, lateralization of the abdominal musculature, polycompartment syndrome, and abdominal compliance, and proposed an open abdomen classification system. RECOMMENDATIONS included intra-abdominal pressure (IAP) measurement, avoidance of sustained IAH, protocolized IAP monitoring and management, decompressive laparotomy for overt ACS, and negative pressure wound therapy and efforts to achieve same-hospital-stay fascial closure among patients with an open abdomen. SUGGESTIONS included use of medical therapies and percutaneous catheter drainage for treatment of IAH/ACS, considering the association between body position and IAP, attempts to avoid a positive fluid balance after initial patient resuscitation, use of enhanced ratios of plasma to red blood cells and prophylactic open abdominal strategies, and avoidance of routine early biologic mesh use among patients with open abdominal wounds. NO RECOMMENDATIONS were possible regarding monitoring of abdominal perfusion pressure or the use of diuretics, renal replacement therapies, albumin, or acute component-parts separation. Conclusion Although IAH and ACS are common and frequently associated with poor outcomes, the overall quality of evidence available to guide development of RECOMMENDATIONS was generally low. Appropriately designed intervention trials are urgently needed for patients with IAH and ACS. Electronic supplementary material The online version of this article (doi:10.1007/s00134-013-2906-z) contains supplementary material, which is available to authorized users.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal.

            The diagnosis of intra-abdominal hypertension (IAH) or abdominal compartment syndrome (ACS) is heavily dependent on the reproducibility of the intra-abdominal pressure (IAP) measurement technique. Recent studies have shown that a clinical estimation of IAP by abdominal girth or by examiner's feel of the tenseness of the abdomen is far from accurate, with a sensitivity of around 40%. Consequently, the IAP needs to be measured with a more accurate, reproducible and reliable tool. The role of the intra-vesical pressure (IVP) as the gold standard for IAP has become a matter of debate. This review will focus on the previously described indirect IAP measurement techniques and will suggest new revised methods of IVP measurement less prone to error. Cost-effective manometry screening techniques will be discussed, as well as some options for the future with microchip transducers.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. I. Definitions.

              Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) have been increasingly recognized in the critically ill over the past decade. The variety of definitions proposed has led to confusion and difficulty in comparing one study to another. An international consensus group of critical care specialists convened at the second World Congress on Abdominal Compartment Syndrome to standardize definitions for IAH and ACS based upon the current understanding of the pathophysiology surrounding these two syndromes. Prior to the conference the authors developed a blueprint for the various definitions, which was further refined both during and after the conference. The present article serves as the final report of the 2004 International ACS Consensus Definitions Conference and is endorsed by the World Society of Abdominal Compartment Syndrome (WSACS). IAH is redefined as an intra-abdominal pressure (IAP) at or above 12 mmHg. ACS is redefined as an IAP above 20 mmHg with evidence of organ dysfunction/failure. ACS is further classified as either primary, secondary, or recurrent based upon the duration and cause of the IAH-induced organ failure. Standards for IAP monitoring are set forth to facilitate accuracy of IAP measurements from patient to patient. State-of-the-art definitions for IAH and ACS are proposed based upon current medical evidence as well as expert opinion. The WSACS recommends that these definitions be used for future clinical and basic science research. Specific guidelines and recommendations for clinical management of patients with IAH/ACS are published in a separate review.
                Bookmark

                Author and article information

                Journal
                LBSIB7
                Life
                Life
                MDPI AG
                2075-1729
                February 2023
                January 30 2023
                : 13
                : 2
                : 384
                Article
                10.3390/life13020384
                9967253
                36836741
                f40f4b2e-9287-4ac2-93f0-e1562445c04f
                © 2023

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article