14
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Myocardial work assessment in severe aortic stenosis undergoing transcatheter aortic valve replacement

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Aims

          Myocardial work is a novel echocardiographic algorithm that corrects speckle-tracking-derived global longitudinal strain (GLS) for afterload using non-invasive systolic blood pressure as a surrogate for left ventricular systolic pressure (LVSP). Yet, in patients with severe aortic stenosis, non-invasive systolic blood pressure does not equal LVSP.

          Methods and results

          We evaluated 35 patients with severe aortic stenosis who underwent transcatheter aortic valve replacement (TAVR). Transthoracic echocardiography, including myocardial mechanics, was performed pre- and post-TAVR. We performed simultaneous echocardiographic and cardiac catheterization measurements in 23 of the 35 patients at the time of TAVR. Peak and mean aortic gradients were calculated from echocardiographic and cardiac catheterization data. Peak-to-peak LV-aortic gradient correlated highly with mean LV-aortic gradient (r = 0.96); measured LVSP correlated highly with our novel method of non-invasively estimated LVSP (non-invasive systolic blood pressure cuff + Doppler-derived mean aortic gradient, r = 0.92). GLS improved from pre- to post-TAVR (−14.2% ± 4.3 vs. −15.1% ± 3.2), and myocardial work reduced from corrected pre-TAVR to post-TAVR (global work index: 1856.2 mmHg% ± 704.6 vs. 1534.8 ± 385.0).

          Conclusion

          We propose that non-invasive assessment of myocardial work can be reliably performed in aortic stenosis by the addition of mean aortic gradient to non-invasive systolic blood pressure. From this analysis, we note the novel and unique finding that GLS can improve as myocardial work reduces post-TAVR in patients with severe aortic stenosis. Both GLS and myocardial work post-TAVR remain below normal values, requiring further studies.

          Related collections

          Most cited references16

          • Record: found
          • Abstract: found
          • Article: not found

          Current and evolving echocardiographic techniques for the quantitative evaluation of cardiac mechanics: ASE/EAE consensus statement on methodology and indications endorsed by the Japanese Society of Echocardiography.

          Echocardiographic imaging is ideally suited for the evaluation of cardiac mechanics because of its intrinsically dynamic nature. Because for decades, echocardiography has been the only imaging modality that allows dynamic imaging of the heart, it is only natural that new, increasingly automated techniques for sophisticated analysis of cardiac mechanics have been driven by researchers and manufacturers of ultrasound imaging equipment.Several such technique shave emerged over the past decades to address the issue of reader's experience and inter measurement variability in interpretation.Some were widely embraced by echocardiographers around the world and became part of the clinical routine,whereas others remained limited to research and exploration of new clinical applications.Two such techniques have dominated the research arena of echocardiography: (1) Doppler based tissue velocity measurements,frequently referred to as tissue Doppler or myocardial Doppler, and (2) speckle tracking on the basis of displacement measurements.Both types of measurements lend themselves to the derivation of multiple parameters of myocardial function. The goal of this document is to focus on the currently available techniques that allow quantitative assessment of myocardial function via image-based analysis of local myocardial dynamics, including Doppler tissue imaging and speckle-tracking echocardiography, as well as integrated backscatter analysis. This document describes the current and potential clinical applications of these techniques and their strengths and weaknesses,briefly surveys a selection of the relevant published literature while highlighting normal and abnormal findings in the context of different cardiovascular pathologies, and summarizes the unresolved issues, future research priorities, and recommended indications for clinical use.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            A novel clinical method for quantification of regional left ventricular pressure–strain loop area: a non-invasive index of myocardial work

            Aims Left ventricular (LV) pressure–strain loop area reflects regional myocardial work and metabolic demand, but the clinical use of this index is limited by the need for invasive pressure. In this study, we introduce a non-invasive method to measure LV pressure–strain loop area. Methods and results Left ventricular pressure was estimated by utilizing the profile of an empiric, normalized reference curve which was adjusted according to the duration of LV isovolumic and ejection phases, as defined by timing of aortic and mitral valve events by echocardiography. Absolute LV systolic pressure was set equal to arterial pressure measured invasively in dogs (n = 12) and non-invasively in patients (n = 18). In six patients, myocardial glucose metabolism was measured by positron emission tomography (PET). First, we studied anaesthetized dogs and observed an excellent correlation (r = 0.96) and a good agreement between estimated LV pressure–strain loop area and loop area by LV micromanometer and sonomicrometry. Secondly, we validated the method in patients with various cardiac disorders, including LV dyssynchrony, and confirmed an excellent correlation (r = 0.99) and a good agreement between pressure–strain loop areas using non-invasive and invasive LV pressure. Non-invasive pressure–strain loop area reflected work when incorporating changes in local LV geometry (r = 0.97) and showed a strong correlation with regional myocardial glucose metabolism by PET (r = 0.81). Conclusions The novel non-invasive method for regional LV pressure–strain loop area corresponded well with invasive measurements and with directly measured myocardial work and it reflected myocardial metabolism. This method for assessment of regional work may be of clinical interest for several patients groups, including LV dyssynchrony and ischaemia.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              A new approach to assess myocardial work by non-invasive left ventricular pressure–strain relations in hypertension and dilated cardiomyopathy

                Bookmark

                Author and article information

                Contributors
                Journal
                European Heart Journal - Cardiovascular Imaging
                Oxford University Press (OUP)
                2047-2404
                2047-2412
                October 27 2020
                October 27 2020
                Affiliations
                [1 ]Aurora Cardiovascular and Thoracic Services, Aurora St. Luke’s Medical Center, University of Wisconsin School of Medicine and Public Health, 2801 W. Kinnickinnic River Parkway, Suite 880, Milwaukee, WI 53215, USA
                [2 ]Cardiovascular Division, Advocate Aurora Research, Advocate Aurora Health, 3033 S 27th Street, Parkway Building Ste. 201, Milwaukee, WI 53215, USA
                Article
                10.1093/ehjci/jeaa257
                33106854
                f50b8f75-cfc4-4085-90f4-ccf59162443e
                © 2020

                https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model

                History

                Comments

                Comment on this article