      Design, construction, and performance of a real-time holographic refractometry prototype for liquid analysis

      , , ,
      Review of Scientific Instruments
      AIP Publishing

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references28

          • Record: found
          • Abstract: found
          • Article: not found

          Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

          The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            In-fiber reflection mode interferometer based on a long-period grating for external refractive-index measurement.

            We present two novel schemes for refractometry based on a long-period fiber grating- (LPG-) based Michelson interferometer. These schemes are designed to overcome the measurement dependence of previously demonstrated LPG-based refractometry on the immersion depth. The first utilizes an unshielded LPG and the second, a shielded one. Both schemes were tested over a certain refractive-index range, and the measurement of glucose concentration in water was experimentally demonstrated. In addition, the temperature sensitivity of the two schemes is discussed.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Analysis of refractometry for determining total plasma protein in hybrid striped bass (Morone chrysops×M. saxatilis) at various salinities

                Bookmark

                Author and article information

                Journal
                Review of Scientific Instruments
                Review of Scientific Instruments
                AIP Publishing
                0034-6748
                1089-7623
                January 2011
                January 2011
                : 82
                : 1
                : 013103
                Article
                10.1063/1.3523049
                fcfe8e1f-bd0a-437a-827d-4e50d743bf9a
                © 2011
                History

                Comments

                Comment on this article