      Ab interno approach to the subconjunctival space using a collagen glaucoma stent.

      1
      Journal of cataract and refractive surgery
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This review considers a minimally invasive ab interno approach to glaucoma filtration surgery. Glaucoma filtration surgery can be defined as an attempt to lower intraocular pressure (IOP) by the surgical formation of an artificial drainage pathway from the anterior chamber to the subconjunctival space. Subconjunctival drainage of aqueous fluid has been a cornerstone of glaucoma surgery for more than a century. Varying techniques have been deployed to provide access to this space. Yet, despite numerous innovations in filtering surgery to achieve safe IOP reduction, too many short-term and long-term complications are associated with this surgery. This article describes the development of a new, soft, and permanent ab interno collagen implant (XEN gel stent) to optimize aqueous drainage to the subconjunctival space. Specific characteristics are critical in designing such an implant. Determining the optimum size of the device lumen to avoid hypotony while maximizing long-term outflow is crucial. Other topics discussed include material, length, diameter, flexibility, stability, and biocompatibility of the implant. Preclinical and human eye testing shows that the implant does not seem to occlude inside the lumen and the implant material does not appear to cause tissue reaction in the eye. The ab interno placement of the stent offers an alternative for lowering IOP with a minimally invasive procedure, minimum conjunctival tissue disruption, restricted flow to avoid hypotony, and long-term safety.

          Related collections

          Author and article information

          Journal
          J Cataract Refract Surg
          Journal of cataract and refractive surgery
          Elsevier BV
          1873-4502
          0886-3350
          Aug 2014
          : 40
          : 8
          Affiliations
          [1 ] From a private practice, Sacramento, California, USA. Electronic address: rlewiseyemd@yahoo.com.
          Article
          S0886-3350(14)00664-6
          10.1016/j.jcrs.2014.01.032
          24943904
          fd225ccd-28c4-49e3-91cc-c803b0ba16cd
          History

          Comments

          Comment on this article