34
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study

      Journal of Biomedicine and Biotechnology
      Hindawi Limited

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references35

          • Record: found
          • Abstract: found
          • Article: not found

          Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries.

          Diagnostic X-rays are the largest man-made source of radiation exposure to the general population, contributing about 14% of the total annual exposure worldwide from all sources. Although diagnostic X-rays provide great benefits, that their use involves some small risk of developing cancer is generally accepted. Our aim was to estimate the extent of this risk on the basis of the annual number of diagnostic X-rays undertaken in the UK and in 14 other developed countries. We combined data on the frequency of diagnostic X-ray use, estimated radiation doses from X-rays to individual body organs, and risk models, based mainly on the Japanese atomic bomb survivors, with population-based cancer incidence rates and mortality rates for all causes of death, using life table methods. Our results indicate that in the UK about 0.6% of the cumulative risk of cancer to age 75 years could be attributable to diagnostic X-rays. This percentage is equivalent to about 700 cases of cancer per year. In 13 other developed countries, estimates of the attributable risk ranged from 0.6% to 1.8%, whereas in Japan, which had the highest estimated annual exposure frequency in the world, it was more than 3%. We provide detailed estimates of the cancer risk from diagnostic X-rays. The calculations involved a number of assumptions and so are inevitably subject to considerable uncertainty. The possibility that we have overestimated the risks cannot be ruled out, but that we have underestimated them substantially seems unlikely.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources--1950-2007.

            The U.S. National Council on Radiation Protection and Measurements and United Nations Scientific Committee on Effects of Atomic Radiation each conducted respective assessments of all radiation sources in the United States and worldwide. The goal of this article is to summarize and combine the results of these two publicly available surveys and to compare the results with historical information. In the United States in 2006, about 377 million diagnostic and interventional radiologic examinations and 18 million nuclear medicine examinations were performed. The United States accounts for about 12% of radiologic procedures and about one-half of nuclear medicine procedures performed worldwide. In the United States, the frequency of diagnostic radiologic examinations has increased almost 10-fold (1950-2006). The U.S. per-capita annual effective dose from medical procedures has increased about sixfold (0.5 mSv [1980] to 3.0 mSv [2006]). Worldwide estimates for 2000-2007 indicate that 3.6 billion medical procedures with ionizing radiation (3.1 billion diagnostic radiologic, 0.5 billion dental, and 37 million nuclear medicine examinations) are performed annually. Worldwide, the average annual per-capita effective dose from medicine (about 0.6 mSv of the total 3.0 mSv received from all sources) has approximately doubled in the past 10-15 years. (c) RSNA, 2009.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Estimated radiation risks potentially associated with full-body CT screening.

              To estimate the radiation-related cancer mortality risks associated with single or repeated full-body computed tomographic (CT) examinations by using standard radiation risk estimation methods. The estimated dose to the lung or stomach from a single full-body CT examination is 14-21 mGy, which corresponds to a dose region for which there is direct evidence of increased cancer mortality in atomic bomb survivors. Total doses for repeated examinations are correspondingly higher. The authors used estimated cancer risks in a U.S. population derived from atomic bomb-associated cancer mortality data, together with calculated organ doses from a full-body CT examination, to estimate the radiation risks associated with single and multiple full-body CT examinations. A single full-body CT examination in a 45-year-old adult would result in an estimated lifetime attributable cancer mortality risk of around 0.08%, with the 95% credibility limits being a factor of 3.2 in either direction. A 45-year-old adult who plans to undergo annual full-body CT examinations up to age 75 (30 examinations) would accrue an overall estimated lifetime attributable risk of cancer mortality of about 1.9%, with the 95% credibility limits being a factor of 2 in either direction. The authors provide estimates of lifetime cancer mortality risks from both single and annual full-body CT examinations. These risk estimates are needed to assess the utility of full-body CT examinations from both an individual and a public health perspective. Copyright RSNA, 2004
                Bookmark

                Author and article information

                Journal
                10.1155/2012/130169
                http://creativecommons.org/licenses/by/3.0/

                Comments

                Comment on this article