      Image quality assessment of a photon counting detector in x-ray projection imaging

      research-article

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The recent advancements in the photon counting detection have created a significant growing research interest in the x-ray imaging. It is essential to objectively understand the image quality parameters of a photon counting detector before developing imaging applications. In this work, we have assessed the imaging quality of a cadmium telluride (CdTe) based PCD in projection imaging mode. The detector is 70.4 mm × 6.6 mm dimensions. The detector has a pixel array of 64×4 with a pixel pitch of 1.1 mm×1.65 mm. With each pixel having 4 channels in its corresponding ASIC, this PCD can create three bin images from a single projection. With a microfocus x-ray source, the imaging quality in each bin image was measured in terms of the spatial resolution, noise, and contrast to noise ratio (CNR). We used 70 kV, 50μA, 10 s (0.5mAs) with 0.5mm thick aluminum (Al) filter for the acquisition of each image. The MTF curves indicated that the spatial resolution for the bin-1, bin-2, and bin-3 was almost identical. The NNPS curves indicated that the noise in bin 1 and bin 2 images was almost the same for all frequencies while bin 3 image had relatively less noise. The CNR analyses showed that the bin-1 image had the highest CNR. As the flux was increased from 0.5 to 1 mAs, the number of detected counts also increased that resulted in the CNR increase. Beyond this flux, the pulse pileup occurred due to which multiple counts were read as single that resulted in few detected counts and lower CNR. The knowledge of the spatial resolution, noise, and CNR in terms of energy binning allows the determination and optimization of imaging techniques necessary for various applications.

          Related collections

          Author and article information

          Journal
          9881767
          22878
          Nucl Instrum Methods Phys Res A
          Nucl Instrum Methods Phys Res A
          Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
          0168-9002
          1872-9576
          14 June 2019
          23 May 2019
          21 September 2019
          21 September 2020
          : 939
          : 83-88
          Affiliations
          [1 ]Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA
          [2 ]Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, 35249, USA
          Author notes
          Article
          PMC7440679 PMC7440679 7440679 nihpa1530583
          10.1016/j.nima.2019.05.054
          7440679
          32831441
          dc46b968-c1ca-4fee-9e72-80165385ca2d
          History
          Categories
          Article

          Comments

          Comment on this article