27
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Evaluation of load-deflection properties of fiber-reinforced composites and its comparison with stainless steel wires

      research-article

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background:

          The aim of this study was to evaluate the response of common sized fiber-reinforced composites (FRCs) to different deflections due to bending forces and comparing it with stainless steel (SS) wires.

          Materials and Methods:

          In this experimental study, two FRC groups with 0.75 mm and 1.2 mm diameters (Everstick Ortho, Stick Tech, Finland) and three SS groups with 0.016 × 0.022 inch, 0.0215 × 0.028 inch and 0.7 mm diameters (3M Uniteck, Monrovia, California, USA) were tested. Each group contained 10 samples that were tested according to a three point bending test. Each group was tested at deflections of 0.5, 1 and 1.5 mm and the data was analyzed using the repeated measure ANOVA by SPSS software (Statistical Package for the Social Sciences, IBM SPSS, Inc. in Chicago, Illinois, USA). P < 0.05 was considered as significant.

          Results:

          The highest recorded load belonged to the 1.2 mm FRC and after that 0.7 mm SS wire, 0.75 mm FRC, 0.0215 × 0.028 inch SS wire and finally 0.016 × 0.022 inch SS wire. The 0.7 mm SS wire and 0.75 mm FRC were compared as retainers and the results showed the 0.7 mm SS wire showed significantly higher load compared with 0.75 mm FRC ( P < 0.05). The 1.2 mm FRC had significantly higher load compared to 0.0215 × 0.028 inch and 0.016 × 0.022 inch SS wires ( P < 0.05).

          Conclusion:

          The results showed that the 1.2 mm FRC group had significantly higher load compared to SS wires and other FRC groups under the 0.5, 1 and 1.5 mm deflections. Therefore, it can be suggested that FRC can be used as an esthetic replacement for SS wires for active and passive purposes in orthodontics.

          Related collections

          Most cited references45

          • Record: found
          • Abstract: found
          • Article: not found

          Glass fibre reinforced versus multistranded bonded orthodontic retainers: a 2 year prospective multi-centre study.

          The objective of this study was to compare glass fibre reinforced (GFR) with multistranded bonded orthodontic retainers in terms of success rate and periodontal implications. A 2 year parallel study was conducted of 184 patients scheduled to receive bonded retainers in the upper and lower anterior segments. In three centres, the patients (mean age 14 years; 90 males and 94 females) were sequentially assigned to receive GFR retainers containing 500 unidirectional glass fibres (GFR500), 1000 unidirectional glass fibres (GFR1000), or multistranded retainers (gold standard). Retainer failures and periodontal conditions were monitored every 6 months. In a control group of 90 subjects without retainers, periodontal conditions were examined (negative control). Of the 274 recruited patients, 15 dropped out during the 2 year study period. Kaplan-Meier plots were drawn to assess survival of the different retainers. The Mantel-Cox log-rank test was used to identify significant differences in survival functions among the groups. Repeated measures analysis of variance and appropriate post hoc tests were adopted to evaluate periodontal conditions over time. GFR retainers showed unacceptably high failure rates in comparison with multistranded retainers (51 versus 12 per cent). The most significant periodontal conditions were found in patients with GFR retainers with no significant differences between the GFR500 and the GFR1000 group for any parameter at any time point. Subjects without retainers showed significantly lower levels of gingival inflammation and plaque accumulation when compared with patients in any retainer group. Multistranded retainers should remain the gold standard for orthodontic retention, although periodontal complications are common. The use of GFR retainers should be discouraged in daily practice.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Bonded orthodontic retainers: a review.

            D Bearn (1995)
            Recent reports have suggested that long-term retention may be required to prevent posttreatment changes. The bonded orthodontic retainer constructed from composite and multistrand orthodontic wire provides an esthetic and efficient system for maintained retention. The development, indications for use, and clinical techniques are described. The range of materials reported for clinical use in construction of bonded orthodontic retainers are reviewed. Recommmendations based on the literature are made. This review implicates placement of insufficient resin or use of a resin with inadequate abrasion resistance in the failure of bonded fixed retainers.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              E-Glass Fiber Reinforced Composites in Dental Applications

                Bookmark

                Author and article information

                Journal
                Dent Res J (Isfahan)
                Dent Res J (Isfahan)
                DRJ
                Dental Research Journal
                Medknow Publications & Media Pvt Ltd (India )
                1735-3327
                2008-0255
                Mar-Apr 2014
                : 11
                : 2
                : 234-239
                Affiliations
                [1 ]Dental Materials Research Center and Department of Orthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
                Author notes
                Address for correspondence: Dr. Tayebe Mamavi, Dental Material Research Center, Department of Orthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran. E-mail: mamavi.tayebe@ 123456yahoo.com
                Article
                DRJ-11-234
                4052650
                d4fc30a6-cf54-4ce5-9e80-6804f3218779
                Copyright: © Dental Research Journal

                This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : May 2013
                : June 2013
                Categories
                Original Article

                Dentistry
                fiber-reinforced composite,load-deflection,stainless steel wire
                Dentistry
                fiber-reinforced composite, load-deflection, stainless steel wire

                Comments

                Comment on this article