      Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies.

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Volumetric-modulated arc therapy (VMAT) has been previously evaluated for several tumor sites and has been shown to provide significant dosimetric and delivery benefits when compared with intensity-modulated radiation therapy (IMRT). To date, there have been no published full reports on the benefits of VMAT use in pancreatic patients compared with IMRT. Ten patients with pancreatic malignancies treated with either IMRT or VMAT were retrospectively identified. Both a double-arc VMAT and a 7-field IMRT plan were generated for each of the 10 patients using the same defined tumor volumes, organs at risk (OAR) volumes, dose, fractionation, and optimization constraints. The planning tumor volume (PTV) maximum dose (55.8 Gy vs. 54.4 Gy), PTV mean dose (53.9 Gy vs. 52.1 Gy), and conformality index (1.11 vs. 0.99) were statistically similar between the IMRT and VMAT plans, respectively. The VMAT plans had a statistically significant reduction in monitor units compared with the IMRT plans (1109 vs. 498, p < 0.001). In addition, the doses to the liver, small bowel, and spinal cord were comparable between the IMRT and VMAT plans. However, the VMAT plans demonstrated a statistically significant reduction in the mean left kidney V(25) (9.4 Gy vs. 2.3 Gy, p = 0.018), mean right kidney V(15) (53.4 Gy vs. 45.9 Gy, p = 0.035), V(20) (32.2 Gy vs. 25.5 Gy, p = 0.016), and V(25) (21.7 Gy vs. 14.9 Gy, p = 0.001). VMAT was investigated in patients with pancreatic malignancies and compared with the current standard of IMRT. VMAT was found to have similar or improved dosimetric parameters for all endpoints considered. Specifically, VMAT provided reduced monitor units and improved bilateral kidney normal tissue dose. The clinical relevance of these benefits in the context of pancreatic cancer patients, however, is currently unclear and requires further investigation.

          Related collections

          Author and article information

          Journal
          Med Dosim
          Medical dosimetry : official journal of the American Association of Medical Dosimetrists
          Elsevier BV
          1873-4022
          1873-4022
          2012
          : 37
          : 3
          Affiliations
          [1 ] Department of Radiation Oncology, Emory University, Atlanta, GA, USA. aali24@emory.edu
          Article
          S0958-3947(11)00203-2
          10.1016/j.meddos.2011.10.001
          22189026
          87e6488f-eb73-467f-9385-29a2994330fc
          History

          Comments

          Comment on this article