      Towards a Clinical Decision Support System for External Beam Radiation Oncology Prostate Cancer Patients: Proton vs. Photon Radiotherapy? A Radiobiological Study of Robustness and Stability

      Cancers
      MDPI

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references46

          • Record: found
          • Abstract: found
          • Article: not found

          The Diagnosis and Treatment of Prostate Cancer: A Review.

          Prostate cancer is the most common cancer diagnosis made in men with more than 160 000 new cases each year in the United States. Although it often has an indolent course, prostate cancer remains the third-leading cause of cancer death in men.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy.

            To provide an analytical description of the effect of random and systematic geometrical deviations on the target dose in radiotherapy and to derive margin rules. The cumulative dose distribution delivered to the clinical target volume (CTV) is expressed analytically. Geometrical deviations are separated into treatment execution (random) and treatment preparation (systematic) variations. The analysis relates each possible preparation (systematic) error to the dose distribution over the CTV and allows computation of the probability distribution of, for instance, the minimum dose delivered to the CTV. The probability distributions of the cumulative dose over a population of patients are called dose-population histograms in short. Large execution (random) variations lead to CTV underdosage for a large number of patients, while the same level of preparation (systematic) errors leads to a much larger underdosage for some of the patients. A single point on the histogram gives a simple "margin recipe." For example, to ensure a minimum dose to the CTV of 95% for 90% of the patients, a margin between CTV and planning target volume (PTV) is required of 2.5 times the total standard deviation (SD) of preparation (systematic) errors (Sigma) plus 1.64 times the total SD of execution (random) errors (sigma') combined with the penumbra width, minus 1.64 times the SD describing the penumbra width (sigma(p)). For a sigma(p) of 3.2 mm, this recipe can be simplified to 2.5 Sigma + 0.7 sigma'. Because this margin excludes rotational errors and shape deviations, it must be considered as a lower limit for safe radiotherapy. Dose-population histograms provide insight into the effects of geometrical deviations on a population of patients. Using a dose-probability based approach, simple algorithms for choosing margins were derived.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate.

              This article presents a method of quantitative assessment of the degree of conformality and its designation by a single numerical value. A conformation number is introduced to evaluate objectively the degree of conformality. A comparison is made between the conformation number as found for external beam treatment plans and ultrasonically guided 125I seed implants for localized prostate cancer. The conformation number in case of a planning target volume irradiated with two opposed open beams, three open beams, and three beams with customized blocks amounted to 0.17, 0.39, and 0.65, respectively. The conformation number as found for ultrasonically guided permanent prostate implants using 125I seeds averaged 0.72. The conformation number is a convenient instrument for indicating the degree of conformality by a single numerical value. Treatments with a conformation number greater than 0.60 might be termed conformal radiotherapy.