Inviting an author to review:
Find an author and click ‘Invite to review selected article’ near their name.
Search for authorsSearch for similar articles
4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Gas chromatography-vacuum ultraviolet detection for classification and speciation of polychlorinated biphenyls in industrial mixtures.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Polychlorinated biphenyls (PCBs) are a group of synthetic chlorinated compounds that have been widely used as dielectric fluids in capacitors and transformers. Due to their toxicity, persistence, and bioaccumulation in the food chain, PCBs are an environmental concern and among the most analyzed compounds in environmental analysis. The most common analytical methods for analysis of PCBs are based on gas chromatography-electron capture detection (GC-ECD) and gas chromatography-mass spectrometry (GC-MS). However, the number of possible congeners (209), similarities of physical and chemical properties, and complexity of sample matrices make it difficult to distinguish and accurately speciate PCB congeners using existing methods. This study presents a new method using gas chromatography with vacuum ultraviolet detection (GC-VUV), which offers absorption detection in the range of 120-240nm, where all chemical species have absorption. The VUV absorption spectra for all 209 PCB congeners were collected and shown to be differentiable. The capability of VUV data analysis software for deconvolution of co-eluting signals was also demonstrated. An automated time interval deconvolution (TID) procedure was applied to rapidly speciate individual PCBs, as well as classify commercial Aroclor mixtures based on their degree of chlorination. The data showed excellent agreement between the stated nominal and determined degrees of chlorination (less than 1% deviation for highly chlorinated mixtures). GC-VUV was verified to provide excellent specificity, high sensitivity (100-150pg limit of detection), and fast data acquisition for this application.

          Related collections

          Author and article information

          Journal
          J Chromatogr A
          Journal of chromatography. A
          Elsevier BV
          1873-3778
          0021-9673
          Mar 24 2017
          : 1490
          Affiliations
          [1 ] Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, TX, 76019, United States.
          [2 ] Restek Corporation, Bellefonte, PA, 16823, United States.
          [3 ] VUV Analytics, Inc., Cedar Park, TX, 78613, United States.
          [4 ] Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, TX, 76019, United States. Electronic address: kschug@uta.edu.
          Article
          S0021-9673(17)30254-6
          10.1016/j.chroma.2017.02.031
          28236461
          05a34dd1-be3e-4d15-bf8a-8d7698c02a67
          Copyright © 2017 Elsevier B.V. All rights reserved.
          History

          Aroclor,Gas phase absorption spectroscopy,PCB analysis,Time interval deconvolution,Vacuum ultraviolet detection

          Comments

          Comment on this article