18
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Comparison of the antiasthmatic, oropharyngeal, and systemic glucocorticoid effects of budesonide administered through a pressurized aerosol plus spacer or the Turbuhaler dry powder inhaler.

      The Journal of Allergy and Clinical Immunology
      Administration, Inhalation, Adult, Aerosols, administration & dosage, pharmacokinetics, Aged, Anti-Inflammatory Agents, therapeutic use, Asthma, blood, drug therapy, Budesonide, Candidiasis, Oral, microbiology, Colony Count, Microbial, Dose-Response Relationship, Drug, Drug Delivery Systems, methods, Eosinophils, Female, Humans, Hydrocortisone, urine, Lung, drug effects, Male, Middle Aged, Nebulizers and Vaporizers, Osteocalcin, Pregnenediones, Respiratory Function Tests

      Read this article at

      ScienceOpenPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To determine therapeutically and systemically equivalent dosages of budesonide inhaled through the Turbuhaler dry powder inhalation device (Astra Pharma Production AB, Södertälje, Sweden) or pressurized metered-dose inhaler (pMDI) plus Nebuhaler spacer (Astra Pharma Production AB), we compared these devices in a randomized, open, parallel-group trial. Adults with moderate to severe asthma inhaled budesonide (0.4, 0.8, 1.6, and 2.4 mg/day), for 2 weeks at each dose level, through the Turbuhaler (n = 30) or pMDI + Nebuhaler (n = 28). Dose-dependent effects were demonstrated on asthma symptoms (p = 0.0001), daily peak expiratory flow (p = 0.02), blood eosinophils (p = 0.0001), urinary cortisol output per day (p = 0.0001), serum cortisol (p = 0.006), serum osteocalcin (p = 0.0001), and the oropharyngeal Candida colony count (p = 0.0007. analysis of covariance). The ratio of the responses to the two inhalation devices approximated 1.0 for each index measured; that is, no significant between-device difference was found (p > or = 0.29). However, the 95% confidence limits for the ratio of their respective systemic effects on osteocalcin production were 0.83 to 1.48. Thus in adults who use inhalation devices efficiently and have optimally controlled asthma, conversions from the pMDI + Nebuhaler to the Turbuhaler may reasonably be made at milligram equivalent doses of budesonide, then down-titrated to minimize possible systemic effects. Because earlier studies have shown that the Turbuhaler can double intrapulmonary drug delivery in comparison with a pMDI without a spacer, a 50% dose reduction may be indicated when converting from a pMDI to the Turbuhaler.

          Related collections

          Author and article information

          Comments

          Comment on this article