      Evaluation of automatic atlas-based lymph node segmentation for head-and-neck cancer.

      International Journal of Radiation Oncology, Biology, Physics
      Algorithms, Head and Neck Neoplasms, radiography, radiotherapy, Humans, Lymph Nodes, anatomy & histology, Medical Illustration, Nasopharyngeal Neoplasms, Observer Variation, Oropharyngeal Neoplasms, Radiotherapy, Intensity-Modulated, methods, Sensitivity and Specificity

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To evaluate if automatic atlas-based lymph node segmentation (LNS) improves efficiency and decreases inter-observer variability while maintaining accuracy. Five physicians with head-and-neck IMRT experience used computed tomography (CT) data from 5 patients to create bilateral neck clinical target volumes covering specified nodal levels. A second contour set was automatically generated using a commercially available atlas. Physicians modified the automatic contours to make them acceptable for treatment planning. To assess contour variability, the Simultaneous Truth and Performance Level Estimation (STAPLE) algorithm was used to take collections of contours and calculate a probabilistic estimate of the "true" segmentation. Differences between the manual, automatic, and automatic-modified (AM) contours were analyzed using multiple metrics. Compared with the "true" segmentation created from manual contours, the automatic contours had a high degree of accuracy, with sensitivity, Dice similarity coefficient, and mean/max surface disagreement values comparable to the average manual contour (86%, 76%, 3.3/17.4 mm automatic vs. 73%, 79%, 2.8/17 mm manual). The AM group was more consistent than the manual group for multiple metrics, most notably reducing the range of contour volume (106-430 mL manual vs. 176-347 mL AM) and percent false positivity (1-37% manual vs. 1-7% AM). Average contouring time savings with the automatic segmentation was 11.5 min per patient, a 35% reduction. Using the STAPLE algorithm to generate "true" contours from multiple physician contours, we demonstrated that, in comparison with manual segmentation, atlas-based automatic LNS for head-and-neck cancer is accurate, efficient, and reduces interobserver variability. (c) 2010 Elsevier Inc. All rights reserved.

          Related collections

          Author and article information

          Comments

          Comment on this article