      Uni- and Bipolar Pacing Threshold Measurements with Capturecontrol, a New Automatic Pacemaker Function for Capture Verification

      case-report

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          It is mandatory in pacemaker patients to determine the pacing threshold at each follow-up visit. To facilitate the pacing threshold measurements, complete automatic pacemaker tests are being developed. A new pacemaker algorithm for automatic capture verification (Capturecontrol) detects the presence of the evoked response signal 70–100 ms after the pacing pulse. The aim of this study was to determine the uni- and bipolar pacing thresholds using this automatic pacemaker function and compare them with the manually determined threshold. The study included 14 patients with the DDD pacemaker Logos (Biotronik) connected to the high-ohmic ventricular pacing lead Synox SX 60-BP (Biotronik). At predischarge and 8, 14, 20 and 26 weeks after implantation the uni- and bipolar pacing thresholds were assessed manually and with the automatic pacemaker function at 0.4 ms duration. Mean pacing thresholds determined with the automatic pacemaker function were not different from the manually measured values. This applied to uni- and bipolar pacing. Seventy percent of all unipolar and 67% of all bipolar measurements had no deviation. A deviation of 0.1 V between manual and automatic threshold measurement was observed in 25% (unipolar) and 28% (bipolar), respectively. A 0.2-volt difference occurred in 3% in the unipolar measurements. Deviations ≥0.3 V were found in 2% of all unipolar and in 5% of all bipolar measurements. In conclusion, automatic pacing threshold measurements using the Capturecontrol algorithm were similar compared to the manually determined thresholds. The excellent agreement between the two methods was observed for bipolar as well as unipolar pacing and on condition that all patients had a high-ohmic ventricular pacing lead. Therefore, fewer requirements are necessary for Capturecontrol than for presently available systems. Such pacemaker functions can help to speed up the measurements during follow-up visits.

          Related collections

          Author and article information

          Journal
          CRD
          Cardiology
          10.1159/issn.0008-6312
          Cardiology
          S. Karger AG
          0008-6312
          1421-9751
          1999
          February 2000
          23 March 2000
          : 92
          : 3
          : 210-213
          Affiliations
          Medical Clinic, Department of Cardiology, University Hospital Eppendorf, Hamburg, Germany
          Article
          6973 Cardiology 1999;92:210–213
          10.1159/000006973
          10754353
          16d04cab-39f3-4bd6-84f6-a16a0505ac0b
          © 2000 S. Karger AG, Basel

          Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          History
          Page count
          Figures: 2, Tables: 2, References: 13, Pages: 4
          Categories
          Case Report

          General medicine,Neurology,Cardiovascular Medicine,Internal medicine,Nephrology
          Pacemaker follow-up,Pacing threshold,Pacemaker function, automatic,DDD pacemaker,Capture verification

          Comments

          Comment on this article