      Analysis of indoor air pollution trends and characterization of infiltration delay time using a cross-correlation method.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          High-density housing in close proximity to freeways in conjunction with high concentrations of traffic emissions may contribute to significant degradation of indoor air quality. Densely populated areas may also be targeted for intentional releases of biological or chemical agents because an urban release could result in higher morbidity and mortality from the attack. Since people tend to spend the majority of their time indoors, it is paramount to explore the relationships between outdoor and indoor air quality and, specifically, the time scales that characterize transport of airborne contaminants from outdoors to indoors. In the Brooklyn Traffic Real-Time Ambient Pollutant Penetration and Environmental Dispersion (B-TRAPPED) study, a three-story row house with a flat face and roof and multiple rooms was used to investigate outdoor-to-indoor contaminant time scales. The building was located in the Sunset Park neighborhood of Brooklyn, NY, USA, in the vicinity of a major expressway and a heavily trafficked arterial road. It was found that the building shell has a profound impact on the indoor concentrations. A strong hourly periodicity (see Eisner et al., this issue, DOI: 10.1039/b907132f) in concentration outside the building during the morning "rush hour" was used as evidence to suggest that indoor contaminants originated from outdoor air penetration. Although the indoor concentrations followed a similar pattern, indoor concentrations were found to be more persistent than outdoor concentrations. Stronger persistency is used here to describe the tendency of the indoor concentration to continue to rise even if the outdoor concentration has started to drop, or vice versa. This may be an important factor in assessing negative health risks to inhabitants or first responders. A cross-correlation technique was employed to study the correlation between outdoor and indoor time series. In the high-density housing residential building used in the study, it was found that a long lag time exists (11 min) before indoor and outdoor concentrations reach maximal correlation.

          Related collections

          Author and article information

          Journal
          J Environ Monit
          Journal of environmental monitoring : JEM
          Royal Society of Chemistry (RSC)
          1464-0333
          1464-0325
          Dec 2009
          : 11
          : 12
          Affiliations
          [1 ] Alion Science and Technology, P.O. Box 12313, Research Triangle Park, NC 27709. eisner.alfred@epa.gov
          Article
          10.1039/b907144j
          20024017
          273e5da2-81e2-486a-86d4-2c7a751e4b1c
          History

          Comments

          Comment on this article